Ali Abedi

Ali Abedi

Auto-generated profile, based on publicly available information

Ali Abedi

Department of Mechanical Engineering, Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Ali AbdaliAli Abdali
Ali Abdali
AAAli Abedi
Ali Abedi
KMKazem Mazlumi
Kazem Mazlumi
Abbas RabieeAbbas Rabiee
Abbas Rabiee
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and following that to the hotspot temperature (HST). In this article, a novel formula is proposed for HST prediction of DTs by considering the effective electrical and mechanical parameters on heat dissipation capacity. Additionally, complete and accurate 3D modeling based on computational fluid dynamics (CFD) is presented to validate the proposed novel formula for HST prediction. In this modeling, the conservator, which plays a key role in the HST value, is accurately modeled. Optical fiber sensors are utilized in the studied 500-kVA DT to verify the accuracy of the proposed HST prediction formula during the experimental temperature rise test. Experimental results show that the proposed formula is highly accurate and has an acceptable correlation with the empirical values. The root-mean-square error, mean error, and average error percentage (AEP) of the proposed formula are 0.3 °C, 0.3 °C, and 0.37%, respectively, in HST transient values, and 0.3 °C, 0.3 °C, and 0.29% in HST steady-state values, which substantiate the precision and proficiency of the proposed HST prediction formula rather than IEC and IEEE equations. Finally, a thermal camera is employed to verify the results of CFD-based 3D modeling in top-oil temperature, bottom-oil temperature, and conservator oil temperature during the experimental tests. According to the measurement results, temperatures of CFD-based 3D simulation and thermal camera in the aforementioned three points are in good agreement with each other and AEP is less than 1.4%, which indicates the accuracy and efficiency of the proposed 3-D modeling.

14 July 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Ali AbdaliAli Abdali
Ali Abdali
HMHossein Masoumkhani
Hossein Masoumkhani
AAAli Abedi
Ali Abedi
KMKazem Mazlumi
Kazem Mazlumi
Abbas RabieeAbbas Rabiee
Abbas Rabiee
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Distribution transformers (DTs) are the most costly and crucial power grid equipment, and accurate investigation of their thermal status can prevent their failure, since insulation condition directly correlates with hotspot temperature (HST). In this article, an accurate and nonuniform magnetic–thermal analysis of DT is proposed for precise HST prediction. In the magnetic analysis, the DT is modeled as a 2-D axial symmetry, and the losses calculation of the windings has been fulfilled as a nonuniform. In the thermal analysis, the DT is modeled as 3-D and nonuniform, and the conservator and core stacking, which has a considerable effect on the HST, are precisely modeled. By taking advantage of optical fiber sensors (OFSs) in the understudied 500-kVA DT, the accuracy of the proposed nonuniform 3-D computational fluid dynamic (CFD)-based modeling during the temperature rise test (TRT) is validated. The empirical evaluation results depict that the presented nonuniform CFD-based thermal analysis for HST prediction is very precise, and there is an appropriate vicinity to the experimental values. The error percentage of the proposed 3-D CFD-based thermal analysis is 0.11% (0.1 °C) compared with the OFSs measurements, which demonstrates the precision and effectiveness of the presented modeling. Also, the verification of the results of nonuniform 3-D CFD-based thermal analysis in top-oil temperature (TOT) and bottom-oil temperature (BOT) during the experimental TRT is fulfilled via thermography. According to the attained evaluated results, temperatures of 3-D CFD-based thermal analysis and thermography in the noted two points are in good accordance with each other. In short, the error percentage is less than 0.65%, which indicates the correctness and proper performance of the proposed 3-D CFD-based modeling. Finally, the proposed nonuniform 3-D model was subjected to the unbalanced load currents of 0.95, 1.05, 1.1, 1.15, and 1.2 of rated current, which increased the HST by −1.6 °C, 1.3 °C, 2.8 °C, 4.3 °C, and 6.0 °C, respectively, over the original model without unbalanced load currents.

24 November 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Ali AbdaliAli Abdali
Ali Abdali
AAAli Abedi
Ali Abedi
KMKazem Mazlumi
Kazem Mazlumi
Abbas RabieeAbbas Rabiee
Abbas Rabiee
JGJosep M. Guerrero
Josep M. Guerrero

1 January 2020 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
STSara Tayari
Sara Tayari
RAReza Abedi
Reza Abedi
AAAli Abedi
Ali Abedi
Microalgae have been mentioned as a promising feedstock for biodiesel production. In this study, microalgae Chlorella vulgaris (MCV) was cultivated in a bioreactor with wastewater. After biodiesel production from MCV oil via transesterification reaction, chemical and physical properties of MCV methyl ester were evaluated with regular diesel and ASTM standard. Besides, engine performance and exhaust emissions of CI engine fuelled with the blends of diesel-biodiesel were measured. The GC-MS analysis showed that oleic and linoleic acids were the main fatty acid compounds in the MCV methyl ester. Engine test results revealed that the use of biodiesel had led to a major decrease in CO and HC emissions and a modest reduction in CO2 emissions, whereas there was a minor increase in NOx emissions. Furthermore, there was a slight decrease in the engine power and torque while a modest increase in brake specific fuel consumption which are acceptable due to exhaust emissions reduction. The experimental results illustrate considerable capabilities of applied MVC biodiesel as an alternative fuel in diesel engines to diminish the emissions.