Hernan Jara

Hernan Jara

Auto-generated profile, based on publicly available information

Hernan Jara

Department of Radiology, Boston Medical Center, Boston University School of Medicine, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 1994 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JFJohn C. Ford
John C. Ford
DHDavid B. Hackney
David B. Hackney
DADavid C. Alsop
David C. Alsop
HJHernan Jara
Hernan Jara
PJPeter M. Joseph
Peter M. Joseph
PBPerry Black
Perry Black

7 March 2012 in JAMA
Verified
Journal Article
Open access
PDF file
SBShalender Bhasin
Shalender Bhasin
TTThomas G. Travison
Thomas G. Travison
TSThomas W. Storer
Thomas W. Storer
KLKishore Lakshman
Kishore Lakshman
MKManas Kaushik
Manas Kaushik
SBShehzad Basaria
Shehzad Basaria
5α-dihydrotestosterone (DHT) is a potent metabolite of testosterone; its role in postembryonic life remains poorly understood. At least 2 isoenzymes of steroid 5α-reductase convert testosterone to DHT in humans.1-3 In marsupials and possibly in humans, DHT also can be produced from other substrates via 1 or more alternate pathways.3-5 Studies of the kindred with steroid 5α-reductase 2 mutations,6,7 and mice with genetic or pharmacological disruption of steroid 5α-reductase enzymes,8,9 suggest that DHT serves an important role in the formation of prostate and phallus.

1 September 1997 in American Journal of Roentgenology
Verified
Journal Article
Closed access
EME R Melhem
E R Melhem
HJH Jara
H Jara
SES Eustace
S Eustace
Using human volunteers and phantoms emulating CSF, we analyzed the effects of varying protein concentration on the signal intensity of saline solution. Also, for different fluid-attenuated inversion recovery (FLAIR) sequences, we compared protein concentration thresholds above which the signal from these solutions becomes hyperintense to that from brain parenchyma.Nine albumin solutions of varying concentrations (3.9 mg/dl to 2500 mg/dl) were imaged using fast FLAIR MR sequences (TR, 6000 msec: inversion time, 1730 msec: echo train length, 20) at different effective TEs (110, 150, 200, and 250 signal-to-noise ratios from the different albumin solutions versus albumin concentration were generated and correlated with average signal-to-noise ratios from brain parenchyma and CSF.We saw a gradual increase in signal-to-noise ratios from the albumin solutions as a function of albumin concentration. As the effective TE increased, the point of intersection between the plots and the average signal-to-noise ratio fr...

1 October 2005 in Radiology
Verified
Journal Article
Closed access
SFSteven W. Farraher
Steven W. Farraher
HJHernan Jara
Hernan Jara
KCKevin J. Chang
Kevin J. Chang
AHAndrew Hou
Andrew Hou
JSJorge A. Soto
Jorge A. Soto
The purpose of this HIPAA-compliant, institutional review board-approved study was to assess the liver and spleen volumes calculated by using a semiautomated dual-space clustering segmentation technique, as compared with the volumes calculated by using the manual contour-tracing method. The quantitative magnetic resonance (MR) imaging data used as input were computed from images acquired by using a mixed fast spin-echo pulse sequence that was implemented with respiratory triggering. Linear regression analysis was used to assess agreement regarding the volumes calculated by using both segmentation techniques. There was strong agreement regarding the regression parameters for the liver (r = 0.98, P < .001) and the spleen (r = 0.99, P < .001) and the mean percentage volume differences for the liver (1.2%) and the spleen (0.9%). The mean segmentation time per patient was significantly shorter with use of the dual-space clustering method (P < .001).

1 October 2022 in Radiology
Verified
Journal Article
Closed access
HJHernán Jara
Hernán Jara
OSOsamu Sakai
Osamu Sakai
EFEzequiel Farrher
Ezequiel Farrher
AOAna-Maria Oros-Peusquens
Ana-Maria Oros-Peusquens
NSN. Jon Shah
N. Jon Shah
KKKathryn E. Keenan
Kathryn E. Keenan
Multiparametric quantitative MRI of the brain has the potential for implementation in a wide range of clinical applications. This review on brain multiparametric quantitative MRI (MP-qMRI) focuses on the primary subset of quantitative MRI (qMRI) parameters that represent the mobile (“free”) and bound (“motion-restricted”...

1 May 2011 in RadioGraphics
Verified
Journal Article
Closed access
BSBhavya Shah
Bhavya Shah
SAStephan W. Anderson
Stephan W. Anderson
JSJonathan Scalera
Jonathan Scalera
HJHernan Jara
Hernan Jara
JSJorge A. Soto
Jorge A. Soto
Quantitative magnetic resonance (MR) imaging seeks to quantify fundamental biologic and MR-inducible tissue properties, in contrast to the routine application of MR imaging in the clinic, in which differences in MR parameters are used to generate contrast for subsequent subjective image analysis. Fundamental parameters that are commonly quantified by using MR imaging include proton density, diffusion, T1 relaxation, T2 and T2* relaxation, and magnetization transfer. Applications of these MR imaging-quantifiable parameters to abdominal imaging include oncologic imaging, evaluation of diffuse liver disease, and assessment of splenic, renal, and pancreatic disease. An understanding of the inherent physical principles underlying the basic quantitative parameters as well as the commonly used pulse sequences requisite to their derivation is critical, as this field is rapidly growing and its use will likely continue to expand in the clinic. The full potential of quantitative MR imaging applied to abdominal imaging has yet to be realized, but the myriad applications reported to date will undoubtedly continue to grow.