Pharmaceuticals and personal care products (PPCPs) are widely detected in aquatic environments. However, recent studies on the environmental occurrence of currently used PPCPs in Japan are limited. In this study, a nationwide monitoring initiative focusing on PPCPs was undertaken to investigate the occurrence and fate of PPCPs in aquatic environments in Japan. A total of 700 samples were collected and analyzed from 2018 to 2022. Ninety-one PPCPs were detected in the analyzed samples. Three PPCPs [N, N-diethyl-meta-toluamide (DEET), salicylic acid, and crotamiton] were detected at particularly high frequencies, with a prevalence exceeding 99% of analyzed samples. Seasonal variations were observed for several PPCPs across multiple rivers, with concentrations generally increasing during fall/winter and decreasing during spring/summer (except DEET) throughout the sampling period. The detection frequencies and concentrations were higher in PPCPs with higher domestic prescription amounts. Some PPCPs, such as acetylsalicylic acid, exhibited low frequencies and concentrations despite high domestic prescription amounts, suggesting transformation into metabolites or degradates in the aquatic environment. The contribution of sewage treatment plant effluent to the PPCP concentrations in the environment was estimated by examining the correlation between each PPCP and sucralose concentration. Sewage effluents appeared to be a significant contributor to the majority of target PPCPs; however, DEET and certain other PPCPs may originate from alternate sources. This study is the first to provide a comprehensive assessment of the occurrence and fate of PPCPs in Japan’s aquatic environment. Future research should assess the environmental and human health risks of these PPCPs and identify the occurrence of their metabolites or degradates in the aquatic environment.
In order to adopt "screening analysis" in drinking water quality testing, which performs qualitative and quantitative analysis based on information registered in a database without measuring standard materials at the time of each testing, a validation test was conducted to evaluate the difference on the chromatogram data analysis by analysts. In the validation test, chromatograms of 6 water samples were analyzed using the same database and software by 16 analysts in 13 laboratories. Peak identification was performed based on Retention time (RT), (qualifier and target ion) QT ratio, and degree of matching of mass spectra, and if necessary, peak shapes in water samples were compared with those in calibration curve samples. Large differences were observed in the detection of pesticides among the analysts. There were two main reasons for the disagreement. The first is that the judgement of peak detection at low concentrations near the quantification limit of each pesticide, particularly below the concentration at three times of quantification limit, differed depending on the analyst. The other reason was that some analysts made clear misidentifications and identified wrong peaks close to the predicted retention time, despite the QT ratio and mass spectrum didn't match that in the database. In addition, there were some cases where the quantified values were reported by misidentifying the peaks of degradation products and metabolites, even when the peak detection was correctly judged. In order to use screening analysis practically by drinking water quality testing laboratories, it is important to conduct a validation test like this study in advance to use screening analysis and to coordinate criteria for peak identification and quantification among data analysts.
1 January 2024 in Journal of Environmental Chemistry
Recovery tests of 25 volatile organic compounds (VOCs) spiked into drinking water were performed under various test conditions to evaluate the effects of cooling experimental apparatuses and solvents and diluting water samples during preparation of calibration standard solutions and water samples on analytical precision for testing the VOCs in drinking water using a purge and trap-gas chromatography/mass spectrometry (PT-GC/MS). As a result, compounds with small Henry's constants (i.e., compounds with high volatility) were more affected in trueness and repeatability when cooling was not applied during the test operations. In addition, when the water sample was diluted, the trueness and repeatability was decreased even if cooling was applied during the test operations. Therefore, it is important to conduct test operations with cooling experimental apparatuses and solvents, and without diluting the sample water to obtain better analytical accuracy in VOC analysis of drinking water samples using PT-GC/MS.