29 May 2019 in Journal of Micromechanics and Microengineering
GTGuilherme Brondani Torri
+4
This paper deals with the design, simulation and characterization of polymer-based piezoelectric micromachined ultrasound transducers (PMUT) (arrays) intended for short-range gesture recognition applications. The presented process flow is fully compatible with existing flat-panel display fabrication. Finite element models were developed for the evaluation of the frequency response, deflection and acoustic pressure output of single PMUT as a function of the membrane diameter. A laser Doppler vibrometer was used to measure the frequency response, membrane velocity and displacement, as well as mode shapes of the microfabricated PMUT in air. An optical microphone was used to measure the pressure emitted by a single PMUT at various distances along the normal axis of the oscillating membrane. A strong correlation between simulations and measurement results is shown. The device geometries most suitable for short-range gesture recognition purposes are selected and the radiation pattern of square arrays is analyzed using simulations. The resonance properties of single PMUT in an array are determined using measurements. An optimized array is used to demonstrate pulse-echo measurements, and the requirements for a simple gesture recognition platform are elucidated.
9 August 2016 in Analytical Chemistry
The detection of single molecules in magnetic microbead microwell array formats revolutionized the development of digital bioassays. However, retrieval of individual magnetic beads from these arrays has not been realized until now despite having great potential for studying captured targets at the individual level. In this paper, optical tweezers were implemented on a digital microfluidic platform for accurate manipulation of single magnetic beads seeded in a microwell array. Successful optical trapping of magnetic beads was found to be dependent on Brownian motion of the beads, suggesting a 99% chance of trapping a vibrating bead. A tailor-made experimental design was used to screen the effect of bead type, ionic buffer strength, surfactant type, and concentration on the Brownian activity of beads in microwells. With the optimal conditions, the manipulation of magnetic beads was demonstrated by their trapping, retrieving, transporting, and repositioning to a desired microwell on the array. The presented platform combines the strengths of digital microfluidics, digital bioassays, and optical tweezers, resulting in a powerful dynamic microwell array system for single molecule and single cell studies.
23 February 2022 in Journal of Microelectromechanical Systems
Here we present an electromechanical lumped equivalent circuit model for the purpose of deriving the electrical input impedance and response of air-coupled axisymmetric polymer-based piezoelectric micromachined ultrasonic transducers (pMUT). In particular, this study presents the derivation and validation of polyvinylidene fluoride-co-trifluoroethylene P(VDF-TrFE) unimorph pMUT equivalent circuit models operating in the fundamental axisymmetric mode. Derivation of the equivalent circuit model is performed via the application of the Rayleigh-Ritz energy method towards determining effective pMUT radii due to an elastic boundary condition. The results of the model are shown to be in good agreement with finite element (FEM) simulations and experimental measurements of discrete pMUTs in air. In particular, the model is able to accurately predict the effective expansion in the pMUT radius due to the elastic boundary. The electromechanical model may also be used as a tool to characterize and/or evaluate the behavior of pMUT designs for ultrasound transducer applications.[2021–0156]
21 December 2020 in Journal of Microelectromechanical Systems
A flexible PMUT device which can be applied on curved surfaces is presented. The oscillation behavior of the device under different curvatures (from ${\kappa } = 0$ to ${\kappa } =20\,\,\text{m}^{\mathbf {-1}}$ ), shows both modal frequency and vibration velocity shifts. The impact of bending of the device is discussed, in terms of stress given to the diaphragm. When the device is curved, additional stress is added to the diaphragm, opposite to the process-originated stress already presents on the device. An analytical model is introduced that explains the mechanical boundary condition of the diaphragm, which is altered when the device is laminated on a curved surface. The model can predict driving frequency and optimum design of the device according to the bending curvature. When the device is bent with a curvature of $\boldsymbol {\kappa } =20\,\,\text{m}^{\mathbf {-1}}$ , a driving frequency shift of around 10 kHz, which is 2% of the center frequency (503kHz) is predicted as well as measured, compared to device on the flat surface. The oscillation performance of the device increases by 37%, following the prediction of the model. [2020-0348]
21 October 2011 in Journal of Micromechanics and Microengineering
1 June 2013 in Sensors and Actuators A: Physical