Gustavo Adolfo Rosales Chávez

Gustavo Adolfo Rosales Chávez

Auto-generated profile, based on publicly available information

Gustavo Adolfo Rosales Chávez

Nuevo Hospital Civil de Guadalajara “Dr. Juan I. Menchaca,” Guadalajara, Jalisco, México

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2021 in Revista Alergia México
Verified
Journal Article
Open access
MBMartin Bedolla-Barajas
Martin Bedolla-Barajas
JMJaime Morales-Romero
Jaime Morales-Romero
TBTonantzin Isis Bedolla-Pulido
Tonantzin Isis Bedolla-Pulido
MFMiriam Montzerrat Flores-Razo
Miriam Montzerrat Flores-Razo
MMMarco Antonio Morales-García
Marco Antonio Morales-García
BPBeatriz Alejandra Paz-Velarde
Beatriz Alejandra Paz-Velarde
Objective: To determine the prevalence of blood eosinophilia in adults with chronic obstructive pulmonary disease (COPD) according to different cut-off points. Methods: A cross-sectional study was carried out in patients with COPD. The frequency of blood eosinophilia was determined by absolute (cells/ µL) and relative (%) eosinophil count. Multivariate methods were used in order to identify the associated factors. Results: 81 patients were included; the mean age was 71.9 ± 9.8 years; 46 (57%) of the patients were men. The prevalence of eosinophilia for the cut-off points of ≥ 100, ≥ 150, ≥ 200, ≥ 300, and ≥ 400 cells/µL was of 64.2%, 37.0%, 16.1%, and 9.9% respectively. Out of 81 patients, 34 (42%) had a relative eosinophil concentration of ≥ 2%; 21 (25.9%) ≥ 3%; 14 patients (17.3%) had ≥ 4%; and 10 patients (12.3%) had ≥ 5%. Eosinophilia of ≥ 100 cells/µL was associated with age of ≥ 80 years (OR = 6.04, p = 0.026), and with the exacerbation of COPD (OR = 9.40, p = 0.038); in contrast, eosinophilia of ≥ 2% was associated only with age of ≥ 80 years (OR = 3.73, p = 0.020). In addition, the eosinophil count of ≥ 100 and < 300 cells/µL was associated with the exacerbation of COPD (OR = 11.00, p = 0.026). Conclusions: Our results suggest that the frequency of eosinophilia in the context of COPD shows substantial variations according to the used definition.

4 August 2026 in Therapeutic Advances in Infectious Disease
Verified
Journal Article
Open access
GRGustavo Rosales-Chavez
Gustavo Rosales-Chavez
PMPedro Martínez
Pedro Martínez
MAMauricio Alfredo Ambriz Alarcón
Mauricio Alfredo Ambriz Alarcón
BMBrian Rafael Rubio Mora
Brian Rafael Rubio Mora
JAJudith Carolina De Arcos-Jiménez
Judith Carolina De Arcos-Jiménez
Jaime Briseno-RamirezJaime Briseno-Ramirez
Jaime Briseno-Ramirez
Background: Pneumocystis jirovecii pneumonia (PJP) in non-HIV immunocompromised adults carries 30%–60% mortality. Adjunctive corticosteroids are standard in HIV-PJP but remain contested in non-HIV PJP. Objectives: To determine whether adjunctive corticosteroids reduce mortality and invasive mechanical ventilation (IMV) in non-HIV PJP, and whether effect estimates differ between randomized and observational study designs. Design: Systematic review and meta-analysis. Data sources and methods: Six databases and two trial registers were searched from inception to February 7, 2026. Randomized and observational studies comparing adjunctive corticosteroids versus no corticosteroids or placebo in non-HIV adults with PJP were eligible. Random-effects meta-analyses (restricted maximum likelihood) of two co-primary outcomes included subgroup, sensitivity, E -value, and Grading of Recommendations Assessment analyses. Results: Twenty-eight studies were included (one randomized controlled trial (RCT), 27 observational; ∼ 5300 patients): 22 contributed corticosteroid-versus-no-corticosteroid comparisons and six contributed dose-comparison data only. Evidence was discordant by design (interaction p = 0 . 006 ): the RCT showed lower IMV (hazard ratio (HR) 0.36, 95% CI 0.14–0.90) and lower 90-day mortality (HR 0.59, 0.37–0.93); regression-adjusted observational studies suggested harm (odds ratio (OR) 1.56, 1.10–2.22); propensity-based estimates were null-compatible. Pre-specified mortality pools were non-significant short-term (OR 1.22, 0.88–1.70) and intermediate-term (OR 1.39, 0.85–2.29). Secondary infections ( k = 4 ): OR 1.04 (0.63–1.72); RCT 0.59 (0.32–1.06). E -values for RCT effects (3.44 IMV; 2.24 mortality) exceeded the 1.81 E -value of the adjusted observational mortality pool. Certainty was very low for pooled mortality and moderate for RCT outcomes. Conclusion: Reliable inference rests on the single RCT rather than the pooled observational estimate, which is discordant by design and most consistent with confounding by indication. In the RCT, corticosteroids did not significantly reduce 28-day mortality but lowered IMV and 90-day mortality and sped respiratory recovery, without clear excess secondary infections (low certainty). Corticosteroids may be considered for severe respiratory failure using the PIC (ClinicalTrials.gov NCT02944045) protocol; adequately powered confirmatory trials are needed. Trial registration : PROSPERO CRD420261304396.

1 February 2026 in CG Ciudad Glocal Revista Científica Mexicana de Movilidad Urbana, Transporte y Territorio
Verified
Journal Article
Open access
CBClarissa Canales Barrena
Clarissa Canales Barrena
FGFatima Daniela Medina Gómez
Fatima Daniela Medina Gómez
GGGabriel González García
Gabriel González García
LSLaura Karina Salas Salazar
Laura Karina Salas Salazar
GCGustavo Adolfo Rosales Chávez
Gustavo Adolfo Rosales Chávez
La producción artesanal de ladrillo es una actividad económica relevante en zonas periurbanas de México; sin embargo, suele realizarse en informalidad y pobre regulación ambiental. En Tlajomulco de Zúñiga esta industria impacta en la calidad del aire y expone a trabajadores y comunidades cercanas a riesgos respiratorios. El objetivo del estudio fue evaluar los niveles de material particulado PM2.5 y PM10 en un parque ladrillero y analizar su asociación con la función pulmonar de los trabajadores. Mediante un diseño observacional transversal se midieron PM2.5 y PM10 en tres zonas del parque, comparando los resultados con los límites de la OMS y SEMARNAT. Además, se aplicaron encuestas y espirometrías a 36 trabajadores, interpretadas según estándares internacionales. La zona de horneado presentó las mayores concentraciones de PM2.5 llegando hasta 2624.9 μg/m3, excediendo más de 50 veces los límites establecidos por la OMS y la SEMARNAT. En cuanto a PM10, el valor máximo alcanzó 4496.2 μg/m3 rebasando más de 100 veces el límite de la OMS. En la evaluación de la función pulmonar (n=36), el 19.5% de los trabajadores presentaron un patrón obstructivo y se identificó una correlación negativa significativa entre los años trabajados y la relación FEV1/FVC (ρ=-0.347; p=0.038). Los hallazgos muestran cómo dicha actividad económica ubicada en la periferia urbana puede generar degradación ambiental sin que sus efectos en salud se manifiesten inmediatamente. Esta situación revela formas de vulnerabilidad estructural asociadas a la producción del espacio urbano donde la exposición ambiental, la informalidad laboral y la limitada vigilancia sanitaria convergen.