6 January 2022 in Journal of Medical Internet Research
Background: The global COVID-19 pandemic has triggered a fundamental reexamination of how human psychological research can be conducted safely and robustly in a new era of digital working and physical distancing. Online web-based testing has risen to the forefront as a promising solution for the rapid mass collection of cognitive data without requiring human contact. However, a long-standing debate exists over the data quality and validity of web-based studies. This study examines the opportunities and challenges afforded by the societal shift toward web-based testing and highlights an urgent need to establish a standard data quality assurance framework for online studies. Objective: This study aims to develop and validate a new supervised online testing methodology, remote guided testing (RGT). Methods: A total of 85 healthy young adults were tested on 10 cognitive tasks assessing executive functioning (flexibility, memory, and inhibition) and learning. Tasks were administered either face-to-face in the laboratory (n=41) or online using remote guided testing (n=44) and delivered using identical web-based platforms (Cambridge Neuropsychological Test Automated Battery, Inquisit, and i-ABC). Data quality was assessed using detailed trial-level measures (missed trials, outlying and excluded responses, and response times) and overall task performance measures. Results: The results indicated that, across all data quality and performance measures, RGT data was statistically-equivalent to in-person data collected in the lab (P>.40 for all comparisons). Moreover, RGT participants out-performed the lab group on measured verbal intelligence (P<.001), which could reflect test environment differences, including possible effects of mask-wearing on communication. Conclusions: These data suggest that the RGT methodology could help ameliorate concerns regarding online data quality—particularly for studies involving high-risk or rare cohorts—and offer an alternative for collecting high-quality human cognitive data without requiring in-person physical attendance.
31 March 2025 in Journal of Neural Engineering
Objective. This study examined the strength and stability of motor signals in low gamma and high gamma bands of vascular electrocorticograms (vECoG) recorded with endovascular stent-electrode arrays (Stentrodes) implanted in the superior sagittal sinus of two participants with severe paralysis due to amyotrophic lateral sclerosis. Approach. vECoG signals were recorded from two participants in the COMMAND trial, an Early Feasibility Study of the Stentrode brain–computer interface (BCI) (NCT05035823). The participants performed attempted movements of their ankles or hands. The signals were band-pass filtered to isolate low gamma (30–70 Hz) and high gamma (70–200 Hz) components. The strength of vECoG motor activity was measured as signal-to-noise ratio (SNR) and the percentage change in signal amplitude between the rest and attempted movement epochs, which we termed depth of modulation (DoM). We trained and tested classifiers to evaluate the accuracy and stability of detecting motor intent. Main results. Both low gamma and high gamma were modulated during attempted movements. For Participant 1, the average DoM across channels and sessions was 125.41 ± 17.53% for low gamma and 54.23 ± 4.52% for high gamma, with corresponding SNR values of 6.75 ± 0.37 dB and 3.69 ± 0.28 dB. For Participant 2, the average DoM was 22.77 ± 4.09% for low gamma and 22.53 ± 2.04% for high gamma, with corresponding SNR values of 1.72 ± 0.25 dB and 1.73 ± 0.13 dB. vECoG amplitudes remained significantly different between rest and move periods over the 3 month testing period, with >90% accuracy in discriminating attempted movement from rest epochs for both participants. For Participant 1, the average DoM was strongest during attempted movements of both ankles, while for Participant 2, the DoM was greatest for attempted movement of the right hand. The overall classification accuracy was 91.43% for Participant 1 and 70.37% for Participant 2 in offline decoding of multiple attempted movements and rest conditions. Significance. By eliminating the need for open brain surgery, the Stentrode offers a promising BCI alternative, potentially enhancing access to BCIs for individuals with severe motor impairments. This study provides preliminary evidence that the Stentrode can detect discriminable signals indicating motor intent, with motor signal modulation observed over the 3 month testing period reported here.
28 February 2025 in Journal of Neural Engineering
The Tenth International brain–computer interface (BCI) meeting was held June 6–9, 2023, in the Sonian Forest in Brussels, Belgium. At that meeting, 21 master classes, organized by the BCI Society’s Postdoc & Student Committee, supported the Society’s goal of fostering learning opportunities and meaningful interactions for trainees in BCI-related fields. Master classes provide an informal environment where senior researchers can give constructive feedback to the trainee on their chosen and specific pursuit. The topics of the master classes span the whole gamut of BCI research and techniques. These include data acquisition, neural decoding and analysis, invasive and noninvasive stimulation, and ethical and transitional considerations. Additionally, master classes spotlight innovations in BCI research. Herein, we discuss what was presented within the master classes by highlighting each trainee and expert researcher, providing relevant background information and results from each presentation, and summarizing discussion and references for further study.
25 September 2025 in medRxiv
Background: Implanted brain-computer interfaces (iBCIs) establish direct communication with the brain and hold the potential to enable people with severe disability to achieve control of digital devices, enabling communication and digital activities of daily living. The ability to access brain signals reliably and continuously over many years post-implantation is crucial for iBCIs to be effective and feasible. This study investigates the signal characteristics and long-term stability of neural activity recorded with a stent-electrode array over 1 year post-implant. Methods: We report on five participants with paralysis who were enrolled in an early feasibility clinical trial of an endovascular iBCI (Stentrode; ClinicalTrials.gov, NCT05035823 ). Each participant was implanted with a 16-channel stent-electrode array, deployed in the superior sagittal sinus to record bilaterally from the primary motor cortices. Neural activity was recorded during home-based sessions while the participants performed a set of standardized tasks. Metrics including motor signal strength during attempted movement, resting state signal features, and electrode impedances were quantified over time. Results: Motor-related modulation in neural activity was exhibited in the high-frequency bands (30-200 Hz) during attempted movements, with rest and attempted movement states showing sustained differentiation over time. Impedance and resting state band power for most channels did not change significantly over time. Conclusions: These findings provide strong evidence that the endovascular BCIs may be suitable for long-term neural signal acquisition in the home environment, demonstrating the ability to record movement-related modulation over one year.
12 January 2026 in bioRxiv
Most individuals with tetraplegia retain some myoelectric function in their forearms, which offers the possibility of using surface electromyographic (sEMG) control for human-computer interaction (HCI). We demonstrate the potential of this approach by showing that people with motor-complete (n=5) and motor-incomplete (n=2) tetraplegia can accurately control myoelectric activity in their forearm to perform discrete button-click and continuous positioning tasks. These control inputs were mapped to the firing rate of motor units detected by a wireless wristband sensor designed for everyday use. Participants completed four testing sessions to assess their speed and accuracy. Motor units that displayed a wide dynamic range in their firing rate performed best during tasks requiring continuous, single-axis control. Interestingly, the level of impairment did not affect performance on the clicking and 1D cursor control tasks. However, those with motor-incomplete injuries showed greater independent control over two motor units than participants with motor-complete injuries, who exhibited stronger coupling between units. Participants also confirmed the practical utility of the device, successfully placing and removing the sEMG wristband on their own and consistently rating it as comfortable and easy to manage. These findings are significant because they offer the first demonstration of motor unit-based control in individuals with cervical spinal cord injury (SCI) using a fully wearable wristband interface, highlighting the feasibility of moving these systems out of the lab and into daily life.