21 February 2019 in International Journal of Computer Assisted Radiology and Surgery
Purpose In the context of minimally invasive neurosurgery, steerable needles such as the one developed within the Horizon2020-funded EDEN2020 project (Frasson et al. in Proc Inst Mech Eng Part H J Eng Med 224(6):775–88, 2010. https://doi.org/10.1243/09544119JEIM663; Secoli and y Baena in IEEE international conference on robotics and automation, 2013) aspire to address the clinical challenge of better treatment for cancer patients. The direct, precise infusion of drugs in the proximity of a tumor has been shown to enhance its effectiveness and diffusion in the surrounding tissue (Vogelbaum and Aghi in Neuro-Oncology 17(suppl 2):ii3–ii8, 2015. https://doi.org/10.1093/neuonc/nou354). However, planning for an appropriate insertion trajectory for needles such as the one proposed by EDEN2020 is challenging due to factors like kinematic constraints, the presence of complex anatomical structures such as brain vessels, and constraints on the required start and target poses. Methods We propose a new parallelizable three-dimensional (3D) path planning approach called Adaptive Hermite Fractal Tree (AHFT), which is able to generate 3D obstacle-free trajectories that satisfy curvature constraints given a specified start and target pose. The AHFT combines the Adaptive Fractal Tree algorithm’s efficiency (Liu et al. in IEEE Robot Autom Lett 1(2):601–608, 2016. https://doi.org/10.1109/LRA.2016.2528292) with optimized geometric Hermite (Yong and Cheng in Comput Aided Geom Des 21(3):281–301, 2004. https://doi.org/10.1016/j.cagd.2003.08.003) curves, which are able to handle heading constraints. Results Simulated results demonstrate the robustness of the AHFT to perturbations of the target position and target heading. Additionally, a simulated preoperative environment, where the surgeon is able to select a desired entry pose on the patient’s skull, confirms the ability of the method to generate multiple feasible trajectories for a patient-specific case. Conclusions The AHFT method can be adopted in any field of application where a 3D path planner with kinematic and heading constraints on both start and end poses is required.
19 February 2021 in IEEE Transactions on Biomedical Engineering
Introduction: Needle-based neurosurgical procedures require high accuracy in catheter positioning to achieve high clinical efficacy. Significant challenges for achieving accurate targeting are (i) tissue deformation (ii) clinical obstacles along the insertion path (iii) catheter control. Objective: We propose a novel path-replanner able to generate an obstacle-free and curvature bounded three-dimensional (3D) path at each time step during insertion, accounting for a constrained target pose and intraoperative anatomical deformation. Additionally, our solution is sufficiently fast to be used in a closed-loop system: needle tip tracking via electromagnetic sensors is used by the path-replanner to automatically guide the programmable bevel-tip needle (PBN) while surgical constraints on sensitive structures avoidance are met. Methods: The generated path is achieved by combining the ”Bubble Bending” method for online path deformation and a 3D extension of a convex optimisation method for path smoothing. Results: Simulation results performed on a realistic dataset show that our replanning method can guide a PBN with bounded curvature to a predefined target pose with an average targeting error of 0.65 ± 0.46 mm in position and 3.25 ± 5.23 degrees in orientation under a deformable simulated environment. The proposed algorithm was also assessed in-vitro on a brain-like gelatin phantom, achieving a target error of 1.81 ± 0.51 mm in position and 5.9 ± 1.42 degrees in orientation. Conclusion: The presented work assessed the performance of a new online steerable needle path-planner able to avoid anatomical obstacles while optimizing surgical criteria. Significance: This method is particularly suited for surgical procedures demanding high accuracy on the desired goal pose under tissue deformations and real-world inaccuracies.
3 February 2021 in IEEE Transactions on Biomedical Engineering
Laser interstitial thermal therapy (LiTT) isa minimally invasive alternative to conventional open surgery for drug-resistant focal mesial temporal lobe epilepsy (MTLE). Recent studies suggest that higher seizure freedom rates are correlated with maximal ablation of the mesialhippocampal head, whilst sparing of the parahippocampal gyrus (PHG) may reduce neuropsychological sequelae. Current commercially available laser catheters are inserted following manually planned straight-line trajectories, which cannot conform to curved brain structures, such as the hippocampus, without causing collateral damage or requiring multiple insertions. Objectives: The clinical feasibility and potential of curved LiTT trajectories through steerable needles has yet to be investigated. This is the focus of our work. Methods: We propose a GPU-accelerated computer-assisted planning (CAP) algorithm for steerable needle insertions that generates optimized curved 3D trajectories with maximal ablation of the amygdalohippocampal complex and minimal collateral damage to nearby structures, while accounting for a variable ablation diameter ( $5-15$ mm). Results: Simulated trajectories and ablations were performed on 5 patients with mesial temporal sclerosis (MTS), which were identified from a prospectively managed database. The algorithm generated obstacle-free paths with significantly greater target area ablation coverage and lower PHG ablation variance compared to straight line trajectories. Conclusions: The presented CAP algorithm returns increased ablation of the amygdalohippocampal complex, with lower patient risk scores compared to straight-line trajectories. Significance: This is the first clinical application of preoperative planning for steerable needle based LiTT. This study suggests that steerableneedles have the potential to improve LiTT procedure efficacy whilst improving the safety and should thus be investigated further.