Antoine Muller

Antoine Muller

Auto-generated profile, based on publicly available information

Antoine Muller

Alpes Lasers 2 , Avenue des Pâquiers 1, 2072 St Blaise, Switzerland

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2021 in Inventions
Verified
Journal Article
Open access
PDF file
Anastasios DoulamisAnastasios Doulamis
Anastasios Doulamis
NDNikolaos Doulamis
Nikolaos Doulamis
AAAikaterini Angeli
Aikaterini Angeli
ALAndreas M. Lazaris
Andreas M. Lazaris
SLSiri Luthman
Siri Luthman
AMAntoine Muller
Antoine Muller
This paper proposes a new photonic-based non-invasive device for managing of Diabetic Foot Ulcers (DFUs) for people suffering from diabetes. DFUs are one of the main severe complications of diabetes, which may lead to major disabilities, such as foot amputation, or even to the death. The proposed device exploits hyperspectral (HSI) and thermal imaging to measure the status of an ulcer, in contrast to the current practice where invasive biopsies are often applied. In particular, these two photonic-based imaging techniques can estimate the biomarkers of oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb), through which the Peripheral Oxygen Saturation (SpO2) and Tissue Oxygen Saturation (StO2) is computed. These factors are very important for the early prediction and prognosis of a DFU. The device is implemented at two editions: the in-home edition suitable for patients and the PRO (professional) edition for the medical staff. The latter is equipped with active photonic tools, such as tuneable diodes, to permit detailed diagnosis and treatment of an ulcer and its progress. The device is enriched with embedding signal processing tools for noise removal and enhancing pixel accuracy using super resolution schemes. In addition, a machine learning framework is adopted, through deep learning structures, to assist the doctors and the patients in understanding the effect of the biomarkers on DFU. The device is to be validated at large scales at three European hospitals (Charité–University Hospital in Berlin, Germany; Attikon in Athens, Greece, and Victor Babes in Timisoara, Romania) for its efficiency and performance.

1 March 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
ACA. Cargioli
A. Cargioli
DPD. Piciocchi
D. Piciocchi
MBMathieu Bertrand
Mathieu Bertrand
RMRichard Maulini
Richard Maulini
SBS. Blaser
S. Blaser
JFJerome Faist
Jerome Faist
In this work, we demonstrate that in a regime of strong modulation, by generating pulses of the length of the order of a few cavity lifetimes (hundreds of ps), a broadband quantum cascade laser can be driven to lase on a bandwidth (250 cm−1) limited by the gain. In addition, the amplitude noise of the radiation was shown to be limited by the detector. A laser linewidth study has been performed under different operating conditions, finding values spanning from 20 to 800 MHz, indicating a trade-off between emission bandwidth, amplitude stability, and coherence. The pulsed intensity of the output arises from the gain switching dynamics of the laser, while the self-seeded nature of the emission is responsible for the low amplitude noise and the relatively narrow linewidth of the individual spectral lines of the multimode emission.

11 August 2022 in Expert Systems with Applications
Verified
Journal Article
Open access
AEAbd Al Rahman M. Abu Ebayyeh
Abd Al Rahman M. Abu Ebayyeh
AMAlireza Mousavi
Alireza Mousavi
Sebelan DanishvarSebelan Danishvar
Sebelan Danishvar
SBStéphane Blaser
Stéphane Blaser
TGTobias Gresch
Tobias Gresch
AMAntoine Müller
Antoine Müller

1 May 2010 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
AMAntoine Müller
Antoine Müller
JFJerome Faist
Jerome Faist

29 June 2020 in Optics Express
Verified
Journal Article
Open access
PDF file
SHSargis Hakobyan
Sargis Hakobyan
RMRichard Maulini
Richard Maulini
SBStéphane Blaser
Stéphane Blaser
TGTobias Gresch
Tobias Gresch
AMAntoine Muller
Antoine Muller
We demonstrate quantum cascade laser (QCL) optical frequency combs emitting at λ ∼ 6 μm. A 5.5 μm-wide, 4.5 mm-long laser exhibits comb operation from −20 °C up to 50 °C. A maximum output power of 300 mW is achieved at 50 °C showing a robustness of the system. The laser output spectrum is ∼80 cm−1 wide at the maximum current, with a mode spacing of 0.334 cm−1, resulting in a total of 240 modes with an average power of 0.8 mW per mode. To achieve frequency comb operation, a plasmonic-waveguide approach is utilized. A thin, highly-doped indium phosphide (InP) layer is inserted in the top cladding design to compensate the positive dispersion of the system (material and waveguide). This approach can be further exploited to design QCL combs at even shorter wavelengths, down to 4 μm. Different ridge widths between 2.8 and 5.5 μm have been fabricated and characterized. All of the devices exhibit frequency comb operation. These observations demonstrate that the plasmonic-waveguide is a robust and reliable method for dispersion compensation of a semiconductor laser systems to achieve frequency comb operation.

28 November 2024 in Optics & Laser Technology
Verified
Journal Article
Open access
FPFlorian Pilat
Florian Pilat
NONikola Opačak
Nikola Opačak
SCSandro Dal Cin
Sandro Dal Cin
AWAndreas Windischhofer
Andreas Windischhofer
EGEtienne Giraud
Etienne Giraud
BSBenedikt Schwarz
Benedikt Schwarz