Philippe Gillet

Philippe Gillet

Auto-generated profile, based on publicly available information

Philippe Gillet

Institute of Tropical Medicine, Antwerp, Belgium

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Clinical Microbiology and Infection
Verified
Journal Article
Open access
PDF file
JMJ. Maltha
J. Maltha
PGP. Gillet
P. Gillet
JJJ. Jacobs
J. Jacobs
Malaria rapid diagnostic tests (RDTs) are instrument-free tests that provide results within 20 min and can be used by community health workers. RDTs detect antigens produced by the Plasmodium parasite such as Plasmodium falciparum histidine-rich protein-2 (PfHPR2) and Plasmodium lactate dehydrogenase (pLDH). The accuracy of RDTs for the diagnosis of uncomplicated P. falciparum infection is equal or superior to routine microscopy (but inferior to expert microscopy). Sensitivity for Plasmodium vivax is 75-100%; for Plasmodium ovale and Plasmodium malariae, diagnostic performance is poor. Design limitations of RDTs include poor sensitivity at low parasite densities, susceptibility to the prozone effect (PfHRP2-detecting RDTs), false-negative results due to PfHRP2 deficiency in the case of pfhrp2 gene deletions (PfHRP2-detecting RDTs), cross-reactions between Plasmodium antigens and detection antibodies, false-positive results by other infections and susceptibility to heat and humidity. End-user's errors relate to safety, procedure (delayed reading, incorrect sample and buffer volumes) and interpretation (not recognizing invalid test results, disregarding faint test lines). Withholding antimalarial treatment in the case of negative RDT results tends to be infrequent and tendencies towards over-prescription of antibiotics have been noted. Numerous shortcomings in RDT kits' labelling, instructions for use (correctness and readability) and contents have been observed. The World Health Organization and partners actively address quality assurance of RDTs by comparative testing of RDTs, inspections of manufacturing sites, lot testing and training tools but no formal external quality assessment programme of end-user performance exists. Elimination of malaria requires RDTs with lower detection limits, for which nucleic acid amplification tests are under development.

30 November 2009 in Malaria Journal
Verified
Journal Article
Open access
PDF file
PGPhilippe Gillet
Philippe Gillet
MMMarcella Mori
Marcella Mori
MEMarjan Van Esbroeck
Marjan Van Esbroeck
JEJef Van Den Ende
Jef Van Den Ende
JJJan Jacobs
Jan Jacobs
The prozone effect (or high doses-hook phenomenon) consists of false-negative or false-low results in immunological tests, due to an excess of either antigens or antibodies. Although frequently cited as a cause of false-negative results in malaria rapid diagnostic tests (RDTs), especially at high parasite densities of Plasmodium falciparum, it has been poorly documented. In this study, a panel of malaria RDTs was challenged with clinical samples with P. falciparum hyperparasitaemia (> 5% infected red blood cells).

28 August 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JMJessica Maltha
Jessica Maltha
DGDionicia Gamboa
Dionicia Gamboa
JBJorge Bendezu
Jorge Bendezu
LSLuis Sanchez
Luis Sanchez
LCLieselotte Cnops
Lieselotte Cnops
JJJan Jacobs
Jan Jacobs
In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity. Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR. Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)- detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%–10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples. PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern.

15 June 2011 in Malaria Journal
Verified
Journal Article
Open access
PDF file
PGPhilippe Gillet
Philippe Gillet
ASAnnelies Scheirlinck
Annelies Scheirlinck
JSJocelijn Stokx
Jocelijn Stokx
AWAnja De Weggheleire
Anja De Weggheleire
HCHélder S Chaúque
Hélder S Chaúque
JJJan Jacobs
Jan Jacobs
Prozone means false-negative or false-low results in antigen-antibody reactions, due to an excess of either antigen or antibody. The present study prospectively assessed its frequency for malaria rapid diagnostic tests (RDTs) and Plasmodium falciparum samples in an endemic field setting.

1 May 2013 in Clinical Microbiology and Infection
Verified
Journal Article
Open access
PDF file
JMJ. Maltha
J. Maltha
PGP. Gillet
P. Gillet
JJJ. Jacobs
J. Jacobs
Malaria is a serious condition in the non-immune traveller, and prognosis depends on timely diagnosis. Although microscopy remains the cornerstone of diagnosis, malaria rapid diagnostic tests (RDTs) are increasingly used in non-endemic settings. They are easy to use, provide results rapidly and require no specific training and equipment. Reported sensitivities vary between different RDT products but are generally good for Plasmodium falciparum, with RDTs detecting the P. falciparum antigen histidine-rich protein-2 (PfHRP2) scoring slightly better than P. falciparum-lactate dehydrogenase (Pf-pLDH)-detecting RDTs. Sensitivity is lower for Plasmodium vivax (66.0 - 88.0%) and poor for Plasmodium ovale (5.5 - 86.7%) and Plasmodium malariae (21.4 - 45.2%). Rapid diagnostic tests have several other limitations, including persistence of the PfHRP2 antigen, cross-reactions of P. falciparum with the non-falciparum test line and vice versa and (rare) false-positive reactions due to other infectious agents or immunological factors. False-negative results occur in the case of low parasite densities, prozone effect or pfhrp2 gene deletions. In addition, errors in interpretation occur, partly due to inadequacies in the instructions for use. Finally, RDTs do not give information about parasite density. In the diagnostic laboratory, RDTs are a valuable adjunct to (but not a replacement for) microscopy for the diagnosis of malaria in the returned traveller.In malaria endemic settings, special groups of travellers (those travelling for long periods, expatriates and short-stay frequent travellers) who are remote from qualified medical services may benefit from self-diagnosis by RDTs, provided they use correctly stored RDT products of proven accuracy, with comprehensive instructions for use and appropriate hands-on training.

23 May 2011 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
JSJocelijn Stokx
Jocelijn Stokx
PGPhilippe Gillet
Philippe Gillet
AWAnja De Weggheleire
Anja De Weggheleire
ECEsther C Casas
Esther C Casas
RMRosa Maendaenda
Rosa Maendaenda
EBEmmanuel Bottieau
Emmanuel Bottieau
Background: The World Health Organization recommends universal and quality-controlled screening of blood donations for the major transfusion-transmissible infections (TTIs): human immunodeficiency virus (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV) and syphilis. The study objectives were to determine the seroprevalence of these TTIs among blood donors at the Provincial Hospital of Tete, Mozambique, and to assess the local pre-donation screening performance.Methods: All consenting voluntary and replacement candidate blood donors were consecutively included from February to May 2009. Sera of all candidates, independent of deferral by questionnaire, were submitted to screening with quality-assured rapid or simple assays for HIV, HBV surface antigen (HBsAg), HCV and syphilis. Assays locally used by the blood bank for HBV and syphilis screening were run in parallel to quality-assured external assays supplied during the study, and all discordant samples were submitted to confirmation testing in reference laboratories in Mozambique and Belgium.Results: Of 750 consenting candidates (50.5% of voluntary donors), 71 (9.5%) were deferred by the questionnaire, including 38 specifically because of risk behavior for TTI. Of the 679 non-deferred candidates, 127 (18.7%) had serological confirmation of at least one TTI, with a lower prevalence in voluntary than in replacement donors (15.2% versus 22.4%, p = 0.016). Seroprevalence of HIV, HBsAg and syphilis infections was 8.5%, 10.6 % and 1.2%. No confirmed HCV infection was found. Seroprevalence of TTIs was similar in the 38 candidates deferred for TTI risk as in the non-deferred group, except for HBsAg (26.3 % versus 10.6 %; p = 0.005). The local assays used for HBV and syphilis had sensitivities of 98.4% and 100% and specificities of 80.4% and 98.8% respectively. This resulted in the rejection of 110 of the 679 blood donations (16.2%) because of false positive results.Conclusions: The seroprevalence of TTIs after questionnaire screening is high in Tete, Mozambique, but HCV infection does not appear as a major issue. The questionnaire did not exclude effectively HIV-infected donor candidates, while the locally used assays led to unnecessary rejection of many safe donations. A contextualized questionnaire and consistent use of quality-assured assays would considerably improve the current screening procedure for blood donation.