Phillip McClellan

Phillip McClellan

Auto-generated profile, based on publicly available information

Phillip McClellan

Department of Mechanical and Aerospace Engineering Case Western Reserve University Cleveland Ohio USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
KCKatherine Chapin
Katherine Chapin
AKAhmad O. Khalifa
Ahmad O. Khalifa
TMThomas Mbimba
Thomas Mbimba
PMPhillip McClellan
Phillip McClellan
JAJames Ross Anderson
James Ross Anderson
OAOzan Akkus
Ozan Akkus
Meshes woven from highly aligned collagen threads crosslinked using either genipin or 1‐ethyl‐3‐(3‐dimethylaminopropyl) carboiimide and N‐hydroxy succinimide (EDC/NHS) were implanted in a subcutaneous rat model to evaluate their biocompatibility (at 2 weeks, 2 months, and 5 months), mechanical properties (at baseline, 2 months, and 5 months) and ultimately their suitability for use as mid‐urethral slings (MUS) for management of stress urinary incontinence. Porcine dermal (Xenmatrix) and monofilament polypropylene (Prolene) meshes were also implanted to provide comparison to clinically used materials. Quantitative histological scoring showed tissue integration in Xenmatrix was almost absent, while the open network of woven collagen and Prolene meshes allowed for cellular and tissue integration. However, strength and stiffness of genipin‐crosslinked collagen (GCC), Prolene, and Xenmatrix meshes were not significantly different from those of native rectus fascia and vaginal tissues of animals at 5 months. EDC/NHS‐crosslinked collagen (ECC) meshes were degraded so extensively at five months that samples could only be used for histological staining. Picrosirius red and Masson's trichrome staining revealed that integrated tissue within GCC meshes was more aligned (p = 0.02) and appeared more concentrated than ECC meshes at 5 months. Furthermore, immunohistochemical staining showed that GCC meshes attracted a greater number of cells expressing markers for M2 macrophages, those associated with regeneration, than ECC meshes (p = 0.01 for CD206+ cells, p = 0.001 CD163+ cells) at 5 months. As such, GCC meshes hold promise as a new MUS biomaterial based on favorable induction of fibrous tissue resulting in mechanical stiffness matching that of native tissue. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 479–489, 2019.

3 August 2022 in Journal of Pediatric Urology
Verified
Journal Article
Closed access
IIILAHA ISALI
ILAHA ISALI
PMPhillip McClellan
Phillip McClellan
TWThomas R. Wong
Thomas R. Wong
SGShubham Gupta
Shubham Gupta
LWLynn Woo
Lynn Woo

18 September 2024 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
IIIlaha Isali
Ilaha Isali
PMPhillip McClellan
Phillip McClellan
TWThomas R. Wong
Thomas R. Wong
SHSara Hijaz
Sara Hijaz
DFDavid R. Fletcher
David R. Fletcher
OAOzan Akkus
Ozan Akkus
Macrophages are involved in several critical activities associated with tissue repair and regeneration. Current approaches in regenerative medicine are focusing on leveraging the innate immune response to accelerate tissue regeneration and improve long‐term healing outcomes. Of particular interest in this regard are the currently known, four main M2 macrophage subtypes: M2interleukin (IL)‐4,IL‐13, M2IC, M2IL‐10, M2non‐selective adenosine receptor agonists (NECA) (M2IL‐4,IL‐13 → M2NECA). In this study, rat bone marrow‐derived macrophages (M0) were polarized to each of the four subtypes M2IL‐4,IL‐13 → M2NECA and cultured for 72 h in vitro. Luminex assay results highlighted increased production of tissue inhibitor of metalloproteinases‐1 (TIMP‐1) for M2IL‐4,IL‐13, higher amounts of transforming growth factor‐beta 1 (TGF‐β1) for M2IL‐10, and elevated vascular endothelial growth factor A (VEGF‐A) from M2NECA. Co‐culture experiments performed with M2IL‐10 macrophages and L929 fibroblasts highlighted the increased production of soluble collagen within the media as well as higher amounts of collagen in the extracellular matrix. Human umbilical vein endothelial cells (HUVECs) were co‐cultured with M2NECA macrophages, which demonstrated an increase in intercellular adhesion molecule (ICAM) and platelet endothelial cell adhesion molecule (PECAM), as well as increased formation of endothelial tubes. The findings of this study emphasize a critical demand for further characterization and analyses of distinct M2 subtypes and careful selection of specific macrophage populations for regeneration of specific tissue types. The current, broad classification of “M2” may be sufficient in many general tissue engineering applications, but, as conditions are constantly in flux within the microenvironment in vivo, a higher degree of specificity and control over the initial M2 subtype could result in more consistent long‐term outcomes where macrophages are utilized as part of an overall regenerative strategy.

10 January 2024 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
JMJacob Morand
Jacob Morand
PMPhillip McClellan
Phillip McClellan
IIILAHA ISALI
ILAHA ISALI
YDYusuf Dikici
Yusuf Dikici
DFDi Fan
Di Fan
MWMark Weidenbecher
Mark Weidenbecher

25 February 2022 in Urologia Internationalis
Verified
Journal Article
Closed access
PDF file
IIILAHA ISALI
ILAHA ISALI
AKAhmad O. Khalifa
Ahmad O. Khalifa
SSSubba Shankar
Subba Shankar
SDStanley Dannemiller
Stanley Dannemiller
WHWalter Horne
Walter Horne
AHAdonis Hijaz
Adonis Hijaz
Introduction: The sheep was evaluated as a potential model for preclinical evaluation of urethral slings in vivo based on: (1) anatomical measurements of the sheep vagina and (2) histological tissue integration and host response to polypropylene (PP) slings. Methods: Eight female, multiparous sheep were utilized. Three of 8 animals underwent surgery mimicking human tension-free vaginal tape protocols for midurethral slings and were euthanized at 6 months. The following measurements were obtained: vaginal length, maximum vaginal width with retraction, symphysis pubis length, and distance from the pubic bone to incision. Explanted sling samples from sheep and human were stained with hematoxylin and eosin for host reaction assessment. Results: Geometric measurements were similar between humans and sheep. Sheep vaginal anatomy allowed sling placement similar to procedures in human surgeries, and all sheep recovered without problems. Comparative histology between the sheep and human indicated similar host reaction and collagen deposition around implants, confirming suitability of the sheep model for biomaterial response assessment. Conclusion: Sheep vaginal length is comparable to humans. Tissue integration and host response to PP slings showed chronic inflammation with rich collagen deposition around the material in both sheep and human specimens, highlighting the sheep as a potential animal model for preclinical testing of midurethral slings.

15 January 2022 in Urologic Oncology: Seminars and Original Investigations
Verified
Journal Article
Closed access
IIIlaha Isali
Ilaha Isali
PMPhillip McClellan
Phillip McClellan
ACAdam Calaway
Adam Calaway
MPMegan Prunty
Megan Prunty
PAPhillip Abbosh
Phillip Abbosh
LBLaura Bukavina
Laura Bukavina