Paula Andrea Ruiz Henao

Paula Andrea Ruiz Henao

Auto-generated profile, based on publicly available information

Paula Andrea Ruiz Henao

Unit of Periodontology, Department of Surgery and Medical‐Surgical Specialties, Faculty of Medicine and Dentistry University of Santiago de Compostela Santiago de Compostela Spain

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
PHPaula Andrea Ruiz Henao
Paula Andrea Ruiz Henao
LQLeticia Caneiro Queija
Leticia Caneiro Queija
SMSantiago Mareque
Santiago Mareque
APAlmudena Tasende Pereira
Almudena Tasende Pereira
ALAntonio Liñares
Antonio Liñares
JCJuan Blanco Carrión
Juan Blanco Carrión

28 June 2024 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PHPaula Andrea Ruiz Henao
Paula Andrea Ruiz Henao
GMGabriel Leonardo Magrin
Gabriel Leonardo Magrin
LCLeticia Caneiro‐Queija
Leticia Caneiro‐Queija
Cesar Augusto BenfattiCesar Augusto Benfatti
Cesar Augusto Benfatti
YLYago Leira
Yago Leira
JBJuan Blanco
Juan Blanco
Objectives: The aim of this study was to evaluate esthetic parameters in the anterior maxillary region by comparing single‐piece zirconia versus titanium narrow‐diameter implants. Additionally, clinical, radiological and patient‐reported outcome measures (PROMs) were analyzed.Materials and Methods: Thirty implants (tissue level implant) were placed in 30 patients in the maxillary esthetic sector. Depending on randomization, a zirconia (test) or titanium implant (control) was placed. Esthetic, clinical, and radiological parameters, including the implant crown esthetic index (ICAI), pink esthetic score (PES), probing pocket depth, bleeding on probing, plaque index, and marginal bone levels, were evaluated at 12, 36 and 60 months after loading.Results: Sixty months after crown placement, no significant differences were found between groups. The ICAI values were 5.25 ± 4.21 and 4.50 ± 2.98 for the test and control groups, respectively. The corresponding PES values were 7.44 ± 1.93 and 7.43 ± 1.74 for the test and control groups, respectively. There were no significant intergroup differences for the rest of the parameters evaluated.Conclusion: It can be suggested that monotype zirconia implants may serve as a potential alternative to titanium implants in selected clinical scenarios. While the results demonstrated comparable esthetic, clinical, and radiological aspects for zirconia implants as compared to titanium implants after a 5‐year follow‐up period, further research with larger sample sizes and longer‐term follow‐up is recommended.