Preksha Gupta

Preksha Gupta

Auto-generated profile, based on publicly available information

Preksha Gupta

Discovery Innovation Accelerator, Centre for Cellular and Molecular Platforms, Bengaluru, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Genes & Development
Verified
Journal Article
Open access
PDF file
TLThais Lavagnolli
Thais Lavagnolli
PGPreksha Gupta
Preksha Gupta
EHEva Hörmanseder
Eva Hörmanseder
HMHegias Mira-Bontenbal
Hegias Mira-Bontenbal
GDGopuraja Dharmalingam
Gopuraja Dharmalingam
MMMatthias Merkenschlager
Matthias Merkenschlager
Cohesin is implicated in establishing and maintaining pluripotency. Whether this is because of essential cohesin functions in the cell cycle or in gene regulation is unknown. Here we tested cohesin’s contribution to reprogramming in systems that reactivate the expression of pluripotency genes in the absence of proliferation (embryonic stem [ES] cell heterokaryons) or DNA replication (nuclear transfer). Contrary to expectations, cohesin depletion enhanced the ability of ES cells to initiate somatic cell reprogramming in heterokaryons. This was explained by increased c-Myc (Myc) expression in cohesin-depleted ES cells, which promoted DNA replication-dependent reprogramming of somatic fusion partners. In contrast, cohesin-depleted somatic cells were poorly reprogrammed in heterokaryons, due in part to defective DNA replication. Pluripotency gene induction was rescued by Myc, which restored DNA replication, and by nuclear transfer, where reprogramming does not require DNA replication. These results redefine cohesin’s role in pluripotency and reveal a novel function for Myc in promoting the replication-dependent reprogramming of somatic nuclei.

1 September 2020 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
AMA. Mohan
A. Mohan
PGP. Gupta
P. Gupta
ANA. P. Nair
A. P. Nair
APAnil Prabhakar
Anil Prabhakar
TST. Saiyed
T. Saiyed
Rapid optical interrogation of flowing cells or particles is a powerful tool in the field of biomedical diagnostics. Determination of size and composition of fast-flowing cells, with diameters in the range of 2– 15 μ m , often require complex open-space optics and expensive high-speed cameras. In this work, a method to overcome these challenges by using a hydrodynamic flow-based microfluidic platform coupled with on-chip integrated fiber optics is reported. The lab-scale portable device developed uses a combination of on-chip lensed and non-lensed optical fibers for precision illumination. The narrow light beam produced by the lensed fiber ( f = 150 μ m ) enables precise optical analysis with high sensitivity. A planar arrangement of optical fibers at various angles facilitates multi-parametric analysis from a single point of interrogation. As proof of concept, the laboratory-scale portable bench-top prototype is used to measure fluorescence signals from CD4 immunostained cells and human blood samples. The performance of microfluidic flow analyzer is also compared to the conventional Guava® easyCyte 8HT flow cytometer.

12 March 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
PGPreksha Gupta
Preksha Gupta
AMAmbili Mohan
Ambili Mohan
AMApurv Mishra
Apurv Mishra
ANAtindra Nair
Atindra Nair
NCNeeladri Chowdhury
Neeladri Chowdhury
TSTaslimarif Saiyed
Taslimarif Saiyed
Droplet microfluidics has emerged as a critical component of several high-throughput single-cell analysis techniques in biomedical research and diagnostics. Despite significant progress in the development of individual assays, multiparametric optical sensing of droplets and their encapsulated contents has been challenging. The current approaches, most commonly involving microscopy-based high-speed imaging of droplets, are technically complex and require expensive instrumentation, limiting their widespread adoption. To address these limitations, we developed the OptiDrop platform; this platform is a novel optofluidic setup that leverages the principles of flow cytometry. Our platform enables on-chip detection of the scatter and multiple fluorescence signals from the microfluidic droplets and their contents using optical fibers. The highly customizable on-chip optical fiber-based signal detection system enables simplified, miniaturized, low-cost, multiparametric sensing of optical signals with high sensitivity and single-cell resolution within each droplet. To demonstrate the ability of the OptiDrop platform, we conducted a differential expression analysis of the major histocompatibility complex (MHC) protein in response to IFNγ stimulation. Our results showed the platform’s ability to sensitively detect cell surface biomarkers using fluorescently labeled antibodies. Thus, the OptiDrop platform combines the versatility of flow cytometry with the power of droplet microfluidics to provide wide-ranging, scalable optical sensing solutions for research and diagnostics.

29 October 2016
Verified
Book Chapter
Closed access
PDF file
PGPreksha Gupta
Preksha Gupta
TLThais Lavagnolli
Thais Lavagnolli
HMHegias Mira-Bontenbal
Hegias Mira-Bontenbal
MMMatthias Merkenschlager
Matthias Merkenschlager

4 May 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
PGPreksha Gupta
Preksha Gupta
AMAmbili Mohan
Ambili Mohan
AMApurv Mishra
Apurv Mishra
ANAtindra Nair
Atindra Nair
NCNeeladri Chowdhury
Neeladri Chowdhury
TSTaslimarif Saiyed
Taslimarif Saiyed
Droplet microfluidics has emerged as a critical component of several high-throughput single cell analysis techniques in biomedical research and diagnostics. However, while there has been significant progress in the individual assays being developed, multi-parametric optical sensing of droplets and their encapsulated contents remains challenging. The current common approach of microscopy based high-speed imaging of droplets is technically complex and requires expensive instrumentation limiting their large-scale adoption. Here we have adapted the principles of the widely established technique of flow cytometry to a novel optofluidic setup – the OptiDrop platform, with on-chip detection of scatter and multiple fluorescence signals from microfluidic droplets and their contents using optical fibers. The highly customizable on-chip optical fiber-based signal detection system enables simplified, miniaturized, low-cost, multi-parametric sensing of optical signals with high sensitivity and single cell resolution within each droplet. Our work on differential expression analysis of the Major Histocompatibility Complex (MHC) protein in response to IFNγ stimulation further demonstrates the OptiDrop platforms capabilities in sensitively detecting cell surface biomarkers using fluorescently labeled antibodies. The OptiDrop platform thus combines the versatility of flow cytometry with the power of droplet microfluidics to provide wide-ranging optical sensing solutions for research and diagnostics.