Guillermo Catuogno

Guillermo Catuogno

Auto-generated profile, based on publicly available information

Guillermo Catuogno

Grupo de Electrónica Aplicada (GEA), UNRC, Río Cuarto, Córdoba, Argentina

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AKAleksej Kiselev
Aleksej Kiselev
GCGuillermo R. Catuogno
Guillermo R. Catuogno
AKAlexander Kuznietsov
Alexander Kuznietsov
RLRoberto Leidhold
Roberto Leidhold
A fault-tolerant permanent magnet synchronous motor drive is proposed in this paper. The strategy is based on finite control-set model predictive control (FCS-MPC) that is easy to implement and replaces the conventional PI controllers and PWM modulators. A three-phase four-wire converter topology is used, which connects the neutral of the motor to the middle of the DC-link in a capacitive divider. The main contribution of the proposed strategy relies on the fact that no reconfigurations or modifications of the converter topology and controller strategy are required from normal operation to post-fault operation. As result, the transition from healthy to faulty state is smooth and not noticeable in the torque waveform. In addition, a simple fault detection method is derived by using the predicted variables. Experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy and shows a pulsation-free torque on fault operation.

1 June 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GCGuillermo R. Catuogno
Guillermo R. Catuogno
GGGuillermo O. Garcia
Guillermo O. Garcia
RLRoberto Leidhold
Roberto Leidhold
A strategy for fault detection and tolerance on the inverter that controls power flow in variable-speed permanent-magnet generators is proposed in this paper. The performance of the proposed strategy is analyzed in two different four-wire topologies. In the first topology, the neutral point of the generator is connected to the middle point of the dc-link capacitor bank, whereas in the second topology, it is connected to a fourth leg of the inverter. The main contribution of this paper resides in the control scheme, which allows a steady operation through a fault occurrence without the need of reconfiguring neither the inverter topology nor the control algorithm. In this way, transients and the use of extra hardware components are avoided. In addition, a control loop that allows limiting the generator losses at any operation point is presented in order to protect the machine. Finally, experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy.

9 April 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GCGuillermo R. Catuogno
Guillermo R. Catuogno
DFDaniel G. Forchetti
Daniel G. Forchetti
RLRoberto Leidhold
Roberto Leidhold
GGGuillermo O. Garcia
Guillermo O. Garcia
The main hypothesis proposed in this paper is that by controlling the harmonic and zero-sequence components of the current in nonsinusoidal permanent-magnet synchronous generators (PMGs), additional energy can be obtained, thereby increasing the machine power density without increasing the Joule effect losses. Two different strategies are proposed for three- and four-wire topologies; therefore, four different cases are analyzed. The strategies consist in controlling the PMG stator currents, following a function that depends on the waveform of the back electromotive force (EMF). The current function is obtained from the instantaneous reactive power theory. An experimental system was built to validate the proposal. Experimental results prove that it is possible to increase power in a tested PMG by 7% using the four-wire topology in comparison with the conventional block commutation and same losses. Higher power gain can be obtained for machines with almost rectangular-shaped EMF waveforms.

1 March 2012
Verified
Conference Paper
Closed access
GCGuillermo Catuogno
Guillermo Catuogno
DFDaniel Forchetti
Daniel Forchetti
GGGuillermo Garcia
Guillermo Garcia
CRCristian Ruschetti
Cristian Ruschetti
RLRoberto Leidhold
Roberto Leidhold
A control method is proposed with the objective of maximizing the energy transference in permanent magnet synchronous generators (PMSG). Such control is based on the evaluation of instantaneous power components as well as of the optimization strategies to obtain the generator reference currents. Two possibilities are studied in the present work: with connection and without connection to neutral, for generators with three different EMF waveforms. In addition, two possibilities for each connection type are also presented in this effort. The first strategy has the main objective of generating at constant power and with minimum losses. On the other hand, the main objective of the second strategy is to get the maximum power while preserving the generator thermal limits. Simulation results are presented and analyzed to validate the proposed strategies. From these results, it can be concluded that when neutral is connected, it is possible to take advantage of the homopolar components of the generator EMF by imposing and adequate current with the objective of maximizing the generator power.

1 October 2012
Verified
Conference Paper
Closed access
GCG. Catuogno
G. Catuogno
DFD. Forchetti
D. Forchetti
GGG. Garcia
G. Garcia
RLR. Leidhold
R. Leidhold
This paper proposes a loss minimization control including fault tolerance for variable-speed permanent magnet synchronous generators, for which it is required that power flows stays constant and the generated energy processed through a AC/DC/AC power converter. It propose and compare two different 4-wires topologies. In the first topology, the neutral point of the generator is connected to a fourth leg of the inverter, and in second topology, it is connected to the midpoint of the DC bus capacitor bank. The main advantage of both options is that once fault occurs, is not necessary to reconfigure the inverter topology which means no need for additional switches. In addition, there is no need for modifying the control algorithm during fault. Another characteristic of the proposed control algorithm is that it allows limiting the generator losses to its maximum admissible value during operation, even under fault conditions. Simulation results are also presented to validate the proposed control strategies.

1 December 2020
Verified
Conference Paper
Closed access
LBLucas D. Bosco
Lucas D. Bosco
GCGuillermo R. Catuogno
Guillermo R. Catuogno
HFHector D. Flores
Hector D. Flores
In this descriptive work, secondary information from the sub-secretariat of Control and Execution of Public Works of the Municipality of Villa Mercedes is analyzed in the period 2017 to 2019, the use of new technologies is proposed to mitigate the consumption of public lighting (AP). The data collection technique was documentary since the documentary review and analysis of the reports presented was carried out. As results, the actions and improvements related to the PA carried out during the 2018-2019 period are presented. The first results of the replacement by LED luminaires show that a reduction of more than 35% was achieved in a main avenue of the city. An economic analysis is proposed to improve in the period 2020-2025.