11 October 2023 in IEEE Transactions on Power Electronics
Artificial neural network (ANN) has recently been considered in weighting factors (WFs) optimization for finite control-set model predictive control (FCS-MPC). However, the training of the traditional ANN is complicated and the predictive accuracy is limited by gradient vanishing. For this motivation, this paper proposes a WFs optimization method based on an aggregated residual network (ResNet) which combines the advantages of residual connection and aggregated transformation. Specifically, the residual connection avoids the gradient vanishing of ANN while the aggregated transformation simplifies the training procedure. Furthermore, the input layer of the designed network incorporates the parameters and working conditions of permanent magnet synchronous motor (PMSM). Consequently, the proposed method is capable of precisely predicting the optimal WFs to enhance the performance of FCS-MPC under various operating conditions. Comparative studies are conducted to highlight the training and generalization ability of the aggregated ResNet. Finally, the feasibility and the dynamic adjustment of the predicted WFs are experimentally validated through a platform of PMSM drives fed by three-level neutral-point-clamped inverter.
9 January 2024 in IEEE Transactions on Power Electronics
Conventional neural network (CNN) has been extensively applied in the field of fault diagnosis for multilevel inverter. However, most CNN based diagnostic strategies are typically implemented offline. To accomplish precise and online diagnosis for the open-circuit (OC) fault of three-level active neutral-point-clamped (3L-ANPC) inverter, the trained CNN is deployed into an edge computation board. Furthermore, this letter utilizes TensorRT to facilitate the lightweight design of the trained CNN, thereby accelerating the diagnosis speed. In order to simplify the offline training, a specific optimization framework is employed to achieve the automatic adjustment of hyperparameters. Comparative evaluations are performed to highlight the training performance and the generalization ability of the proposed CNN. Finally, the proposed online diagnosis is experimentally validated through a 3L-ANPC inverter fed permanent magnet synchronous motor (PMSM) drives.
31 August 2023 in IEEE Transactions on Industry Applications
This paper proposes a novel open-circuit (OC) fault diagnosis method for three-level active neutral-point-clamped (3L-ANPC) inverter. This fault diagnosis method is integrated in the receding optimization of the model predictive control (MPC), where the predictive current model is built to estimate the current vector under the normal and switch OC fault-assumed conditions. The predictive current vector residual between the measured current and predictive current is utilized to distinguish the faulty switch module. Owning to the iterative optimization of the MPC, the predictive current vector residual can be calculated within each control interval, thus achieving fast online diagnosis. Besides, a count function is defined for preventing the misdiagnosis, enhancing the algorithm robustness. Simulations are conducted under different OC faults to evaluate the effectiveness of the defined diagnosis thresholds. Finally, the feasibility of the proposed method is validated experimentally on a 3L-ANPC inverter fed permanent magnet synchronous motor (PMSM) drives.
5 September 2024 in IEEE Transactions on Power Electronics
Hybrid active neutral-point-clamped (HANPC) inverters have been recently considered as an attractive solution for high-power applications, while their control with multiple objectives remains quite complicated. The model predictive control (MPC) is an optimal control technique for multilevel inverters due to its powerful ability to handle the multiobjective optimization and nonlinear constrains. However, the tuning of weighting factors (WFs) in MPC is quite challenging and requires additional computational resources. For this motivation, this article proposes a deep residual network optimization approach for the dynamical WFs tuning of the finite control set (FCS) MPC in the HANPC inverters. The proposed method utilizes the residual connection to avoid the problem of gradient vanishing, so as to improve the predictive accuracy. To realize the dynamic adjustment of WFs, a look-up table is formulated with the predicted WFs, then this look-up table is integrated into the FCS-MPC. Consequently, the proposed method occupies less logic resources in the MPC algorithm, providing the desired behavior with fast dynamic response. Comparative studies are presented to evaluate the training and prediction performance of the networks. Finally, the experimental validations are conducted on a platform of HANPC-inverter-fed permanent magnet synchronous motor drive.
20 November 2023 in IEEE Transactions on Power Electronics
Model predictive control (MPC) has recently been considered for many permanent magnet synchronous motor (PMSM) drive applications. However, the conventional MPC presents insufficient overmodulation capability and, thus, cannot reach the six-step operation, which limits its application in the traction drive areas. This article proposes a novel MPC-based six-step operation scheme for the PMSM drive in traction applications. The prediction horizon is extended to the whole commutation period of the six-step operation, and a new average current-based objective function is introduced to determine the optimal commutation instants. To enhance the method's precision, a trapezoidal discretization method has been adopted in the long-horizon prediction. The effectiveness of the proposed method has been validated by detailed studies. The proposed method is demonstrated to have excellent current-tracking accuracy and fast dynamic response in the six-step operation, which is an advantage over the existing methods.
14 April 2025 in IEEE Transactions on Industrial Electronics
Multiple open-circuit (OC) faults have severely deteriorated the reliable operation of active neutral-point-clamped (ANPC) inverters. To achieve fast and accurate detection for multiple OC faults of three-level ANPC (3L-ANPC) inverter, this article deploys a lightweight convolutional neural network (CNN) into an edge computation board. Specifically, the proposed online diagnosis includes offline training and online deployment. During the offline training, a multisource information fusion is devised to promote the effective feature extraction, thereby enhancing the predictive accuracy of the designed CNN. Furthermore, a specific optimization framework is utilized to simplify the offline training process. For online deployment, the lightweight design of the trained CNN is realized by employing the TensorRT to reduce the computation cost and accelerate the diagnostic speed. Comparative studies are conducted to verify the advantages and the generalization ability of the designed CNN. Finally, the feasibility of the proposed edge-based diagnosis strategy is experimentally verified through the platform of the permanent magnet synchronous motor drives fed by 3L-ANPC inverter.