Hulya Yavuz Ersan

Hulya Yavuz Ersan

Auto-generated profile, based on publicly available information

Hulya Yavuz Ersan

Hacettepe University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2019 in Environmental Research and Technology
Verified
Journal Article
Open access
PDF file
EAEmine Altun
Emine Altun
EÇEda Çelik
Eda Çelik
HEHülya Yavuz Ersan
Hülya Yavuz Ersan
Chitosan has applications in different industries, due to the superior properties, causing an increase in the production of chitosan containing waste. Although composting is the most suitable method for biodegradable wastes like chitosan, less is known about the degradation of chitosan within the composting environment. In this study, biodegradation behavior of bare chitosan films and neutralized chitosan films were investigated under controlled composting environment according to international standards. CO2 emission data showed higher degradation rate of bare chitosan films compared with neutralized chitosan films, which was also supported by SEM images and digital photographs in addition to the TGA and FTIR results. It can be concluded that the biodegradation rate of chitosan films under the composting environment is highly related to the amount of glycerol present in the films and the extraction rate of glycerol from film structure.

28 September 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MEMehmet Fazil Enkavi
Mehmet Fazil Enkavi
HUHasan Uysal
Hasan Uysal
KOKaan Oysul
Kaan Oysul
SSSait Sirin
Sait Sirin
HEHulya Yavuz Ersan
Hulya Yavuz Ersan
Objective. To develop a high-spatial-resolution Cherenkov-excited fluorescence dosimetry system (CEFD) with rapid optical readout using quinine sulfate solution and evaluate its feasibility for small-field dosimetry and verification of patient-derived stereotactic radiosurgery (SRS) dose distributions. Approach. A 3D-printed optical phantom containing 1 g l −1 quinine sulfate solution was imaged with a complementary metal-oxide-semiconductor camera through a 45° mirror. Sensitive-volume thicknesses of 2.5, 5, 10 and 15 mm were compared using calibration response, signal-to-noise ratio, output factors, dose-rate dependence, and small-field beam profiles benchmarked against a PTW 60023 microSilicon detector. The selected CEFD configuration was further evaluated for thermal response, repeatability, signal drift, low-MU response, and small-field gamma performance, and then used for fixed-gantry verification of 31 patient-derived SRS dose distributions. GafChromic EBT3 film was used as the high-spatial-resolution comparator. Main results. The CEFD achieved 0.065 mm pixel −1 spatial sampling. CEFD-10 showed the most balanced overall performance across sensitivity, dose-rate response, output-factor agreement, and small-field profile measurements. Dose-rate deviations remained within 1.7% at 300–1400 MU min −1 . Passive heat sinking reduced the coefficient of variation from 0.26%–0.13% and limited signal drift from 4.3%–0.97% over 30 consecutive measurements. For the 0.5 × 0.5 cm 2 field, the CEFD-10 central-axis dose ratio relative to the treatment planning system-projected dose remained within ±2% from 10 MU onward. For 0.5 × 0.5–3 × 3 cm 2 static fields, CEFD-10 achieved 99.56%–100.0% global 2%/1 mm gamma passing rates with a 10% low-dose threshold. For patient-derived SRS verification, CEFD-10 achieved mean global gamma passing rates of 99.47 ± 1.58% and 97.53 ± 3.58% for 2%/2 mm and 2%/1 mm criteria, respectively, with mean differences from EBT3 film of −0.32% and −0.21%, respectively. Significance. This study demonstrates compact, high-spatial-resolution, rapid-readout optical dosimetry for small-field and patient-derived SRS dose patterns. Agreement with EBT3 film supports CEFD-10 as a controlled-geometry SRS dose verification.