Background: Hearing impairment is the most frequent sensory deficit in humans, affecting more than 360 million people worldwide. In fact, hearing impairment is not merely a health problem, but it also has a great impact on the educational performance, economic income, and quality of life. Hearing impairment is therefore an important social concern. Objective: We aimed to evaluate and compare the accuracy of self-perception, Hearing Handicap Inventory for the Elderly-Screening (HHIE-S) questionnaire, free-field voice test, and smartphone-based audiometry as tests for screening moderate hearing impairment in older adults in China. Methods: In this study, 41 patients were recruited through a single otology practice. All patients were older than 65 years. Patients with otorrhea and cognitive impairment were excluded. Moderate hearing impairment was defined as mean hearing thresholds at 500, 1000, 2000, and 4000 Hz >40 dB hearing loss (pure-tone average > 40 dB hearing loss). All patients completed 5 hearing tests, namely, the self-perception test, HHIE-S questionnaire test, free-field voice test, smartphone-based audiometry test, and standard pure-tone audiometry by the same audiologist. We compared the results of these tests to the standard audiogram in the better-hearing ear. Results: The sensitivity and the specificity of the self-perception test were 0.58 (95% CI 0.29-0.84) and 0.34 (95% CI 0.19-0.54), respectively. The sensitivity and the specificity of the HHIE-S questionnaire test were 0.67 (95% CI 0.35-0.89) and 0.31 (95% CI 0.316-0.51), respectively. The sensitivity and the specificity of the free-field voice test were 0.83 (95% CI 0.51-0.97) and 0.41 (95% CI 0.24-0.61), respectively. The sensitivity and the specificity of the smartphone-based audiometry test were 0.92 (95% CI 0.60-0.99) and 0.76 (95% CI 0.56-0.89), respectively. Smartphone-based audiometry correctly diagnosed the presence of hearing loss with high sensitivity and high specificity. Conclusions: Smartphone-based audiometry may be a dependable screening test to rule out moderate hearing impairment in the older population.
The anatomy of the nasal cavity lateral wall is quite complex; this is where most anatomical anomalies occur. The secondary middle turbinate, a bony projection that arises from the lateral nasal wall, is a rare variation, differing from the accessory middle turbinate by its distinct developmental origin. We report on an unusual case involving a combination of these two turbinate variations. We believe that detailed knowledge of anatomical anomalies in the sinonasal tract is critical for successful clinical management and important in allowing the surgeon to perform safe functional endoscopic sinus surgery.
Sinonasal organized hematoma (SNOH) is rarely encountered in clinical practice. The disease demonstrates a high tendency for occurrence in East Asian individuals, and in the majority of cases, is located in the maxillary sinus. The current report presents the case of an 81-year-old female who developed a space-occupying lesion, which masqueraded as a skull base malignancy, following surgery for the treatment of isolated sphenoid sinus aspergilloma. Subsequent endoscopic endonasal surgery confirmed the diagnosis of an OH of the sphenoid sinus. The patient recovered from all neurological deficits within two months, with the exception of the loss of visual perception. Although SNOH presents a diagnostic challenge, when physicians possess knowledge of its typical imaging features, this facilitates the achievement of a correct diagnosis and the prescription of optimal treatment.
1 January 2008 in Otolaryngology–Head and Neck Surgery
BACKGROUND Hearing impairment is the most frequent sensory deficit in humans, affecting more than 360 million people worldwide. In fact, hearing impairment is not merely a health problem, but it also has a great impact on the educational performance, economic income, and quality of life. Hearing impairment is therefore an important social concern. OBJECTIVE We aimed to evaluate and compare the accuracy of self-perception, Hearing Handicap Inventory for the Elderly-Screening (HHIE-S) questionnaire, free-field voice test, and smartphone-based audiometry as tests for screening moderate hearing impairment in older adults in China. METHODS In this study, 41 patients were recruited through a single otology practice. All patients were older than 65 years. Patients with otorrhea and cognitive impairment were excluded. Moderate hearing impairment was defined as mean hearing thresholds at 500, 1000, 2000, and 4000 Hz >40 dB hearing loss (pure-tone average > 40 dB hearing loss). All patients completed 5 hearing tests, namely, the self-perception test, HHIE-S questionnaire test, free-field voice test, smartphone-based audiometry test, and standard pure-tone audiometry by the same audiologist. We compared the results of these tests to the standard audiogram in the better-hearing ear. RESULTS The sensitivity and the specificity of the self-perception test were 0.58 (95% CI 0.29-0.84) and 0.34 (95% CI 0.19-0.54), respectively. The sensitivity and the specificity of the HHIE-S questionnaire test were 0.67 (95% CI 0.35-0.89) and 0.31 (95% CI 0.316-0.51), respectively. The sensitivity and the specificity of the free-field voice test were 0.83 (95% CI 0.51-0.97) and 0.41 (95% CI 0.24-0.61), respectively. The sensitivity and the specificity of the smartphone-based audiometry test were 0.92 (95% CI 0.60-0.99) and 0.76 (95% CI 0.56-0.89), respectively. Smartphone-based audiometry correctly diagnosed the presence of hearing loss with high sensitivity and high specificity. CONCLUSIONS Smartphone-based audiometry may be a dependable screening test to rule out moderate hearing impairment in the older population.