Angelika Niemz

Angelika Niemz

Auto-generated profile, based on publicly available information

Angelika Niemz

Keck Graduate Institute of Applied Life Sciences, Claremont, CA

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in Trends in Biotechnology
Verified
Journal Article
Closed access
ANAngelika Niemz
Angelika Niemz
TFTanya M. Ferguson
Tanya M. Ferguson
DBDavid S. Boyle
David S. Boyle

13 November 1998 in Accounts of Chemical Research
Verified
Journal Article
Closed access
ANAngelika Niemz
Angelika Niemz
VRVincent M. Rotello
Vincent M. Rotello

26 August 2008 in Biochemistry
Verified
Journal Article
Closed access
ETEric Tan
Eric Tan
BEBarbara Erwin
Barbara Erwin
SDShale Dames
Shale Dames
TFTanya Ferguson
Tanya Ferguson
MBMegan Buechel
Megan Buechel
ANAngelika Niemz
Angelika Niemz

1 May 1995 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
EBEric Breinlinger
Eric Breinlinger
ANAngelika Niemz
Angelika Niemz
VRVincent M. Rotello
Vincent M. Rotello

1 February 1997 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
ANAngelika Niemz
Angelika Niemz
JIJason Imbriglio
Jason Imbriglio
VRVincent M. Rotello
Vincent M. Rotello

1 July 2011 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
PVPeter E. Vandeventer
Peter E. Vandeventer
KWKris M. Weigel
Kris M. Weigel
JSJose Salazar
Jose Salazar
BEBarbara Erwin
Barbara Erwin
BIBruce Irvine
Bruce Irvine
ANAngelika Niemz
Angelika Niemz
Molecular detection of microorganisms requires microbial cell disruption to release nucleic acids. Sensitive detection of thick-walled microorganisms such as Bacillus spores and Mycobacterium cells typically necessitates mechanical disruption through bead beating or sonication, using benchtop instruments that require line power. Miniaturized, low-power, battery-operated devices are needed to facilitate mechanical pathogen disruption for nucleic acid testing at the point of care and in field settings. We assessed the lysis efficiency of a very small disposable bead blender called OmniLyse relative to the industry standard benchtop Biospec Mini-BeadBeater. The OmniLyse weighs approximately 3 g, at a size of approximately 1.1 cm 3 without the battery pack. Both instruments were used to mechanically lyse Bacillus subtilis spores and Mycobacterium bovis BCG cells. The relative lysis efficiency was assessed through real-time PCR. Cycle threshold ( C T ) values obtained at all microbial cell concentrations were similar between the two devices, indicating that the lysis efficiencies of the OmniLyse and the BioSpec Mini-BeadBeater were comparable. As an internal control, genomic DNA from a different organism was spiked at a constant concentration into each sample upstream of lysis. The C T values for PCR amplification of lysed samples using primers specific to this internal control were comparable between the two devices, indicating negligible PCR inhibition or other secondary effects. Overall, the OmniLyse device was found to effectively lyse tough-walled organisms in a very small, disposable, battery-operated format, which is expected to facilitate sensitive point-of-care nucleic acid testing.