Bing Liu

Bing Liu

Auto-generated profile, based on publicly available information

Bing Liu

College of Chemistry and Chemical Engineering, Shaanxi Key Laboratory of Chemical Additives for Industry, Shaanxi University of Science and Technology, Xi’an 710021, Shaanxi Province, P. R. China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
MSMei-Lin Shen
Mei-Lin Shen
BLBing Liu
Bing Liu
LXLing Xu
Ling Xu
HJHuan Jiao
Huan Jiao
2,6-Dipicolinic acid (DPA) is an anthrax biomarker, whose detection is in great need. This work presented nine MOFs of three series containing three ligands of 2,6-naphthalene-dicarboxylic acid (H2NDC), 4,4′-biphenyldicarboxylic acid (H2BPDC), and 1,4-benzenedicarboxylate acid (H2BDC): six single Ln-MOFs (Ln = Eu3+ (1, 4 and 7) and Tb3+ (2, 5 and 8)) and three hetero Eu/Tb-MOFs (3, 6, and 9). This work aimed at ligand regulation of the fluorescence properties and DPA detection. The solid-state emissions of 3, 6, and 9 can be assigned to the characteristic transitions of Eu3+ (5D0 → 7FJ (J = 1–4)) and/or Tb3+ (5D4 → 7FJ (J = 6–3)). The hetero MOFs were applied as fluorescence sensors in DPA detection. The fluorescence and DPA detection performances of 3, 6 and 9 are related to the energy differences between the ligands/DPA and Ln3+, showing the effect of ligand energy regulation and the competition between the three ligands and DPA. The detection performances of 3, 6 and 9 show linear responses of ITb/IEuvs. DPA concentration with the limit of detections of 0.248 μM (3), 0.874 μM (6), and 2.277 μM (9). Seven interferents did not affect the DPA detection using 3, 6 and 9. Time-dependent fluorescence measurement suggested that 3, 6 and 9 responded very fast to DPA. High recoveries in the DPA detection of 3, 6 and 9 in human serum (93.96 to 108.84%) indicated their high reliabilities. The paper-based MOF sensors of 3, 6 and 9 could display emission color changes depending on CDPA, which offers a fast field detection method for DPA.

26 August 2022 in Inorganic Chemistry
Verified
Journal Article
Closed access
WMWei-Ni Miao
Wei-Ni Miao
BLBing Liu
Bing Liu
HLHong Li
Hong Li
SZShu-Jin Zheng
Shu-Jin Zheng
HJHuan Jiao
Huan Jiao
LXLing Xu
Ling Xu

4 November 2020 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
XCXuan-Bo Chen
Xuan-Bo Chen
CQCui-Xing Qi
Cui-Xing Qi
YXYu-Bin Xu
Yu-Bin Xu
HLHong Li
Hong Li
LXLing Xu
Ling Xu
BLBing Liu
Bing Liu
Tb 0.875 Eu 0.125 -Hddb and its paper-based sensor are ratiometric fluorescent sensors for DPA with high sensitivity, selectivity, rapid response and durability.

18 November 2020 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
HLHong Li
Hong Li
BLBing Liu
Bing Liu
LXLing Xu
Ling Xu
HJHuan Jiao
Huan Jiao
A ratiometric fluorescent sensor [Eu0.05Tb0.95(OBA)(H2O)Cl] detects pH and water, whose paper-based sensor can be applied in on-site pH detection.

12 October 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
ZMZhen-Zhen Ma
Zhen-Zhen Ma
YWYue-Shu Wang
Yue-Shu Wang
BLBing Liu
Bing Liu
HJHuan Jiao
Huan Jiao
LXLing Xu
Ling Xu
A 3D cobalt metal–organic framework (Co–MOF), [Co3(BDC)3(DMU)2], was utilized to prepare Cu@Co–MOF composite in a deposition–reduction process. Cu@Co–MOF/GCE (GCE = glassy carbon electrode) electrode was prepared by “drop–coating” method. Cu@Co–MOF/GCE shows excellent electrocatalytic activity for Glu detection. The chronoamperometric response of Cu@Co–MOF/GCE to Glu concentration (CGlu) displays linear relationships in two CGlu sections with calculated sensitivities of 282.89 μA mM−1 cm−2 within 0.005–0.4 mM Glu and 113.15 μA mM−1 cm−2 within 0.4–1.8 mM Glu. The detection limit is calculated as 1.6 μM at S/N = 3. Cu@Co–MOF/GCE also exhibits a rapid current response, high anti–interference, stability, and repeatability to Glu detection. Cu@Co–MOF/GCE was applied to detect Glu in human serum and orange juice. All found CGlu are very close to those added CGlu with low RSDs and high recoveries. Cu@Co–MOF/GCE as a non–enzymatic electrochemical sensor of Glu has high sensitivity, selectivity, accuracy, and reliability.

1 March 2022 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
ZCZong-Ju Chen
Zong-Ju Chen
YZYi Zhang
Yi Zhang
LZLiang Zheng
Liang Zheng
HZHua Zhang
Hua Zhang
HSHui-Hong Shi
Hui-Hong Shi
BLBing Liu
Bing Liu