15 September 2011 in IEEE Transactions on Industrial Electronics
This paper presents a current controller based on a stationary reference frame implementation of an integrator in the synchronous reference frame [called here reduced order generalized integrator (ROGI)], suitable for three-phase distributed generation systems. The proposed controller is compared with the traditional second-order generalized integrator (SOGI)-based current controller. It is confirmed that, in normal operation conditions, both controllers have similar performance, requiring the ROGI-based controller much less computational burden than the SOGI counterpart. The proposed controller injects sinusoidal currents synchronized with the grid voltage, without requiring any dedicated synchronization algorithm. Three different current injection strategies are realizable with the same controller structure: balanced current injection, constant instantaneous active power injection, and maximum instantaneous active power injection. A state-variable-based control methodology in the discrete-time domain is presented. It ensures the stability and performance of the closed-loop system, even for high-order controllers and large digital signal processor processing delay. Moreover, it is confirmed that the proposed controller works satisfactorily even on faulty grid conditions.
20 April 2015 in IEEE Transactions on Industrial Electronics
This paper presents a method for the active damping of a grid-tie $LCL$ inverter. This method is based solely on the feedback of the injected current into the grid and is applicable to any linear current controller. It requires a low additional computational load over that required to control a grid-tie $L$ inverter and the same measurements. A general design methodology for the current controller, which allows positioning all of the closed-loop poles of the system at arbitrary locations (even unstable modes of the $LCL$ filter), is proposed. Stability and robustness of the resulting system are analyzed. Simulation and experimental results that validate the proposal are presented.
15 January 2015 in IEEE Transactions on Power Electronics
In this paper, a nonlinear control strategy for controlling a dc/dc buck converter feeding a constant power load is proposed. The main objective of the proposed controller is to improve the transient performance when in presence of unknown power disturbances. A feedback controller is combined with a feedforward strategy. A nonlinear reduced order observer is used for estimating the value of the power load and its time derivative. These estimated values are fed forward to the nonlinear feedback controller whose design is based on feedback linearization method. The proposed controller is tested via simulation and experimental results.
19 July 2012 in IEEE Transactions on Industrial Electronics
This paper analyzes the behavior of a non-frequency-adaptive reduced-order-generalized-integrator-based current controller when the grid frequency is subject to variations and proposes a simple method for making it frequency adaptive. The proposed frequency adaptation scheme allows to keep the good performance of the current controller even in the presence of frequency variations. The resulting frequency-adaptive controller has very low computational burden, and it is therefore suitable for low-cost digital-signal-processor implementation.
23 January 2012 in IEEE Transactions on Power Electronics
This paper presents a frequency adaptive discrete-time-domain nonlinear filter for three-phase grid synchronization. Due to the discrete time nature of the proposal, all the analysis performed here is valid for a DSP implementation, and this implementation is straightforward. The proposed algorithm has very low computational burden, as in its basic form it only requires three states.
8 September 2017 in IEEE Transactions on Industrial Electronics
This paper highlights the limitations of the dynamic response of a grid-tied inverter connected through an inductor L when it is controlled using a proportional+resonant controller. Then, a new resonant current controller structure is proposed. This structure can be used to control the current injected by a grid-tied inverter through an L filter. When compared to the classic design, the proposed controller has better transient response, both to current reference and grid voltage changes. This is verified through simulation and experimental results.