15 October 2019 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
JSJoakim da Silva
Joakim da Silva
FGFredrik Grönberg
Fredrik Grönberg
BCBjörn Cederström
Björn Cederström
MPMats Persson
Mats Persson
MSMartin Sjölin
Martin Sjölin
MDMats Danielsson
Mats Danielsson
<!-- *** Custom HTML *** --> Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype 19 lp / cm are detectable with the same clarity as 14 lp / cm on the reference scanner at equal dose and reconstruction grid, with more line pairs visible with increasing dose and decreasing image pixel size. The high spatial resolution remains evident in the anatomy of the skull phantom and is comparable to that of other photon-counting CT prototypes present in the literature. We conclude that the deep silicon-based detector used in our study could provide improved spatial resolution in patient imaging without increasing the x-ray dose.

1 March 2013 in Acta Radiologica
Verified
Journal Article
Closed access
SKSamuel Kuttner
Samuel Kuttner
RBRobert Bujila
Robert Bujila
MKMika Kortesniemi
Mika Kortesniemi
HAHenrik Andersson
Henrik Andersson
LKLove Kull
Love Kull
ITIvanka Sojat Tarp
Ivanka Sojat Tarp
Background Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. Purpose To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Material and Methods Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. Results The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Conclusion Based on international references and medical physicists’ practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.

14 June 2018 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
RBRobert Bujila
Robert Bujila
LKLove Kull
Love Kull
MDMats Danielsson
Mats Danielsson
JAJonas Andersson
Jonas Andersson
Purpose: The weighted CT dose index (CTDIw) has been extended for a nominal total collimation width (nT) greater than 40 mm and relies on measurements of . The purpose of this work was to compare three methods of measuring and subsequent calculations of CTDIw to investigate their clinical appropriateness.Methods: The , for multiple nTs up to 160 mm, was calculated from (1) high‐resolution air kerma profiles from a step‐and‐shoot translation of a liquid ionization chamber (LIC) (considered to be a dosimetric reference), (2) pencil ionization chamber (PIC) measurements at multiple contiguous positions, and (3) air kerma profiles obtained through the continuous translation of a solid‐state detector. The resulting was used to calculate the CTDIw, per the extended formalism, and compared.Results: The LIC indicated that a 40 mm nT should not be excluded from the extension of the CTDIw formalism. The solid‐state detector differed by as much as 8% compared to the LIC. The PIC was the most straightforward method and gave equivalent results to the LIC.Conclusions: The CTDIw calculated with the latest CTDI formalism will differ most for 160 mm nTs (e.g., whole‐organ perfusion or coronary CT angiography) compared to the previous CTDI formalism. Inaccuracies in the measurement of will subsequently manifest themselves as erroneous calculations of the CTDIw, for nTs greater than 40 mm, with the latest CTDI formalism. The PIC was found to be the most clinically feasible method and was validated against the LIC.