30 January 2015 in Journal of Applied Crystallography
The quality of diffraction data obtained using silver and molybdenum microsources has been compared for six model compounds with a wide range of absorption factors. The experiments were performed on two 30 W air-cooled Incoatec IµS microfocus sources with multilayer optics mounted on a Bruker D8 goniometer with a SMART APEX II CCD detector. All data were analysed, processed and refined using standard Bruker software. The results show that Ag Kα radiation can be beneficial when heavy elements are involved. A numerical absorption correction based on the positions and indices of the crystal faces is shown to be of limited use for the highly focused microsource beams, presumably because the assumption that the crystal is completely bathed in a (top-hat profile) beam of uniform intensity is no longer valid. Fortunately the empirical corrections implemented inSADABS, although originally intended as a correction for absorption, also correct rather well for the variations in the effective volume of the crystal irradiated. In three of the cases studied (two Ag and one Mo) the finalSHELXL R1 against all data after application of empirical corrections implemented inSADABSwas below 1%. Since such corrections are designed to optimize the agreement of the intensities of equivalent reflections with different paths through the crystal but the same Bragg 2θ angles, a further correction is required for the 2θ dependence of the absorption. For this,SADABSuses the transmission factor of a spherical crystal with a user-defined value of μr(where μ is the linear absorption coefficient andris the effective radius of the crystal); the best results are obtained whenris biased towards the smallest crystal dimension. The results presented here suggest that the IUCr publication requirement that a numerical absorption correction must be applied for strongly absorbing crystals is in need of revision.
1 August 1993 in Journal of Applied Crystallography
15 July 2009 in Angewandte Chemie International Edition
1 January 1998 in Chemical Society Reviews
Ever since Wilhelm Conrad Röntgen discovered X-rays a century ago and von Laue, Friedrich, Knipping, Braggs and Braggs developed an analytical method almost nine decades ago, single crystal structure analysis has become the most powerful analytical tool used to elucidate unequivocally the three dimensional structure of solid matter. New X-ray detectors like image plates or CCD-detectors permit the collection of two datasets a day. However, this recent development should not only result in a higher ‘turn-over’ of crystal structure determinations, but should also be utilized in new research approaches. One can think of monitoring chemical reactions in terms of Echtzeit crystallography. The challenge is to synthesize, crystallize and analyze reaction intermediates by cryo crystal structure determination. Alkali organometallic compounds are omnipresent in any chemical laboratory where they are used as highly reactive starting materials in a vast number of reactions. It would be of great use to be able to freeze out intermediates along a reaction pathway in order to deduce new synthetic routes and concepts from the structural knowledge obtained by single crystal structure determinations.
19 October 2004 in The Journal of Organic Chemistry
31 December 2009 in Journal of the American Chemical Society