Andrew L. Goertzen

Andrew L. Goertzen

Auto-generated profile, based on publicly available information

Andrew L. Goertzen

Department of Radiology, University of Manitoba, Winnipeg, Manitoba, Canada

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
DHDidier Hans
Didier Hans
AGAndrew L Goertzen
Andrew L Goertzen
MKMarc-Antoine Krieg
Marc-Antoine Krieg
WLWilliam D Leslie
William D Leslie
The measurement of BMD by dual‐energy X‐ray absorptiometry (DXA) is the “gold standard” for diagnosing osteoporosis but does not directly reflect deterioration in bone microarchitecture. The trabecular bone score (TBS), a novel gray‐level texture measurement that can be extracted from DXA images, correlates with 3D parameters of bone microarchitecture. Our aim was to evaluate the ability of lumbar spine TBS to predict future clinical osteoporotic fractures. A total of 29,407 women 50 years of age or older at the time of baseline hip and spine DXA were identified from a database containing all clinical results for the Province of Manitoba, Canada. Health service records were assessed for the incidence of nontraumatic osteoporotic fracture codes subsequent to BMD testing (mean follow‐up 4.7 years). Lumbar spine TBS was derived for each spine DXA examination blinded to clinical parameters and outcomes. Osteoporotic fractures were identified in 1668 (5.7%) women, including 439 (1.5%) spine and 293 (1.0%) hip fractures. Significantly lower spine TBS and BMD were identified in women with major osteoporotic, spine, and hip fractures (all p < 0.0001). Spine TBS and BMD predicted fractures equally well, and the combination was superior to either measurement alone (p < 0.001). Spine TBS predicts osteoporotic fractures and provides information that is independent of spine and hip BMD. Combining the TBS trabecular texture index with BMD incrementally improves fracture prediction in postmenopausal women. © 2011 American Society for Bone and Mineral Research

15 July 2000 in Physical Review B
Verified
Journal Article
Closed access
PDF file
ZLZhengyou Liu
Zhengyou Liu
Che Ting ChanChe Ting Chan
Che Ting Chan
Ping ShengPing Sheng
Ping Sheng
AGA. L. Goertzen
A. L. Goertzen
JPJ. H. Page
J. H. Page
We extend the multiple-scattering theory for elastic waves by taking into account the full vector character. The formalism for both the band structure calculation and the reflection and transmission calculations for finite slabs is presented. The latter is based on a double-layer scheme which obtains the reflection and transmission matrix elements for the multilayer slab from those of a single layer. As a demonstration of applications of the formalism, we calculate the band structures of elastic waves propagating in a three-dimensional periodic arrangement of spherical particles and voids, as well as the transmission coefficients through finite slabs. In contrast with the plane-wave method, the multiple-scattering approach exhibits advantages in handling specialized geometries (spherical geometry in the present case). We also present a comparison between theory and ultrasound experiment for a hexagonal-close-packed array of steel balls immersed in water. Excellent agreement is obtained.

14 June 2012 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
AGAndrew L. Goertzen
Andrew L. Goertzen
QBQinan Bao
Qinan Bao
MBMélanie Bergeron
Mélanie Bergeron
EBEric Blankemeyer
Eric Blankemeyer
SBStephan Blinder
Stephan Blinder
RLRichard Laforest
Richard Laforest
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods: We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results: The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion: Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.

8 April 2013 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
AGAndrew L. Goertzen
Andrew L. Goertzen
XZXuezhu Zhang
Xuezhu Zhang
MMMegan M. McClarty
Megan M. McClarty
EBEric J. Berg
Eric J. Berg
CLChen-Yi Liu
Chen-Yi Liu
CTChristopher J. Thompson
Christopher J. Thompson
A silicon photomultiplier (SiPM)-based positron emission tomography (PET) detector was developed using a resistor network charge division multiplexing circuit for detector readout. The detector consists of a lutetium-yttrium oxy-orthosilicate (LYSO) scintillation crystal array, an SiPM array detector (SPMArray 4, SensL Inc., Cork, Ireland) and the resistor multiplexing network implemented in a through-hole package to facilitate changing of resistor values. For purposes of optimizing the readout circuit, the LYSO array used was a 4 4 crystal array with crystal size mm on a pitch of 3.37 mm, matched to the SiPM pixel size. Flood image, energy resolution, photopeak amplitude, timing resolution, and signal time-pickoff measurements were performed using standard NIM electronics. The resistor network values were optimized through an iterative process. The performance of the detector was evaluated over a range of temperatures from 23°C to 60°C by heating the detector. The ability of the detector to resolve crystals smaller than the SiPM pixel pitch was evaluated using a dual-layer LYSO array with crystals of 1.67-mm pitch. The optimal resistor network values were found to be 100 Ω along the rows connecting the SiPM pixels and 56 Ω for the columns. For these resistor value settings, the average energy resolution for the central four crystals in the array at 23.5°C was 13.3% ± 0.3% and degraded to 16.3% ± 0.3% at 60°C. The photopeak amplitude decreased by 2%/°C, and the timing resolution degraded from 3.43 ± 0.22 ns to 4.64 ± 0.25 ns for a 350-750-keV energy window over this temperature range. The signal time-pick-off point shifted earlier by 2.7 ns as the temperature increased, an effect likely due to changes in the signal shape with temperature. The detector was able to resolve all 113 crystals in the dual-layer LYSO array. These results demonstrate that the resistor multiplexing readout circuit functions well for reading out SiPM array based detectors, which use scintillator crystal arrays much smaller than the SiPM pixel pitch. The reduced number of output signals achieved through this signal multiplexing greatly reduces the number of signal cables required. In addition, the ability of this detector to function over a wide range of temperatures offers significant flexibility in defining the system operating temperature set point.

3 December 2002 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AGAndrew L Goertzen
Andrew L Goertzen
AMA Ken Meadors
A Ken Meadors
RSRobert W Silverman
Robert W Silverman
SCSimon R Cherry
Simon R Cherry
Non-invasive imaging technologies are opening up new windows into mouse biology. We have developed a mouse imaging system that integrates positron emission tomography (PET) with x-ray computed tomography (CT), allowing simultaneous anatomic and molecular imaging in vivo with the potential for precise registration of the two image volumes. The x-ray system consists of a compact mini-focal x-ray tube and an amorphous selenium flat panel x-ray detector with a low-noise CMOS readout. The PET system uses planar arrays of lutetium oxyorthosilicate scintillator coupled to position-sensitive photomultiplier tubes. We describe the design of this dual-modality imaging system and show, for the first time, simultaneously acquired PET and CT images in a phantom and in mice.

5 September 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAudrey Katako
Audrey Katako
PSPaul Shelton
Paul Shelton
AGAndrew L. Goertzen
Andrew L. Goertzen
DLDaniel Levin
Daniel Levin
BBBohdan Bybel
Bohdan Bybel
JKJi Hyun Ko
Ji Hyun Ko
Utilizing the publicly available neuroimaging database enabled by Alzheimer’s disease Neuroimaging Initiative (ADNI; http://adni.loni.usc.edu/), we have compared the performance of automated classification algorithms that differentiate AD vs. normal subjects using Positron Emission Tomography (PET) with fluorodeoxyglucose (FDG). General linear model, scaled subprofile modeling and support vector machines were examined. Among the tested classification methods, support vector machine with Iterative Single Data Algorithm produced the best performance, i.e., sensitivity (0.84) × specificity (0.95), by 10-fold cross-validation. We have applied the same classification algorithm to four different datasets from ADNI, Health Science Centre (Winnipeg, Canada), Dong-A University Hospital (Busan, S. Korea) and Asan Medical Centre (Seoul, S. Korea). Our data analyses confirmed that the support vector machine with Iterative Single Data Algorithm showed the best performance in prediction of future development of AD from the prodromal stage (mild cognitive impairment), and that it was also sensitive to other types of dementia such as Parkinson’s Disease Dementia and Dementia with Lewy Bodies, and that perfusion imaging using single photon emission computed tomography may achieve a similar accuracy to that of FDG-PET.