5 November 2018 in Semiconductor Science and Technology
Process-induced basal plane dislocations (BPDs) formed by annealing after aluminum ion implantation were investigated, and their effect on the bipolar degradation of body diodes in 3.3 kV SiC MOSFETs was evaluated. Contact resistance in the p+ region decreases with ion dose but increases with implantation temperature due to the formation of the recrystallized layer at SiC surface and difference of acceptor activation rates in high and low temperature implantation. In the case of high ion dose implantation at room temperature, contact resistance was of 1.3 × 10 −3 Ωcm 2 . However, process-induced BPDs formed with high ion dose implantation at room temperature, and could be suppressed with low ion dose or high implantation temperature. They were formed after activation annealing, and expanded to form stacking faults (SFs) under both continuous irradiation from a Hg lamp and current stress. Bipolar degradation occurred in the case of MOSFETs fabricated using high ion dose implantation at room temperature, but was not observed in the case of either low ion dose or high implantation temperature. The activation energy for SF expansion velocity in the 〈1–100〉 direction was estimated to be 0.20 eV at a forward current density of 125 A cm −2 . Moreover, the results of a long duration current stress test with high current density and high junction temperature indicate that low ion dose or high implantation temperature can suppress the formation of process-induced BPDs. MOSFETs fabricated using optimized ion implantation conditions show high reliability under bipolar operation.
21 October 2021 in Journal of Synchrotron Radiation
The SAGA Light Source provides X-ray imaging resources based on high-intensity synchrotron radiation (SR) emitted from the superconducting wiggler at beamline 07 (BL07). By combining quasi-monochromatic SR obtained by the newly installed water-cooled metal filter and monochromatic SR selected by a Ge double-crystal monochromator (DCM) with high-resolution lens-coupled X-ray imagers, fast and low-dose micro-computed tomography (CT), fast phase-contrast CT using grating-based X-ray interferometry, and 2D micro-X-ray absorption fine structure analysis can be performed. In addition, by combining monochromatic SR obtained by a Si DCM with large-area fiber-coupled X-ray imagers, high-sensitivity phase-contrast CT using crystal-based X-ray interferometry can be performed. Low-temperature CT can be performed using the newly installed cryogenic system, and time-resolved analysis of the crystallinity of semiconductor devices in operation can be performed using a time-resolved topography system. The details of each instrument and imaging method, together with exemplary measurements, are presented.
1 March 2022 in AIP Advances
We investigated the nucleation sites of expanded single Shockley-type stacking faults (1SSFs) in a silicon carbide (SiC) metal–oxide–semiconductor field effect transistor (MOSFET) and demonstrated epitaxial layers designed for bipolar-degradation-free SiC MOSFETs. Since the sufficient hole density just below the basal plane dislocation (BPD)-threading edge dislocation (TED) conversion points induces 1SSF expansion, we derived the dependence of the nucleation depth on the applied current condition from the BPD-TED conversion points of 1SSFs. We first simulated and determined the three-step current conditions applied to a body diode in a SiC MOSFET so that a sufficient amount of holes would be supplied to the drift layer, to the buffer layer, and inside the substrate in the SiC MOSFET. An in operando x-ray topography analysis was conducted with the determined conditions for dynamically visualizing 1SSF expansion motions, and 1SSFs expanded at different forward current densities were successfully extracted. The depths of the BPD-TED conversion points of the extracted 1SSFs were analyzed, and it was experimentally clarified that these depths, i.e., the nucleation sites of expanded 1SSFs, became deeper with forward current densities. The bipolar degradation characteristics of SiC MOSFETs were evaluated as a function of the forward current density, and the validity of the simulation model was verified by experimental results. We also confirmed that bipolar degradation can be suppressed to some extent by using a substrate with a low BPD density, and SiC MOSFETs with a high-nitrogen-concentration epitaxial layer showed high reliability under bipolar operation. Depending on the application of SiC MOSFETs, the epitaxial layers should be designed to prevent the hole density inside the substrate from exceeding the threshold for 1SSF expansion.
11 January 2019 in Journal of Electronic Materials
14 October 2021 in Journal of Applied Physics
We developed an in-operando x-ray topography method for dynamically visualizing single Shockley-type stacking fault (1SSF) expansion motions in silicon carbide (SiC) metal–oxide–semiconductor field-effect transistors (MOSFETs) during their operations and investigated the effect of the operating condition applied to the body diodes in SiC MOSFETs on dislocation glide velocity. In-operando x-ray topography observations were carried out in reflection geometry, and a high-resolution x-ray camera was used as a detector to record topographies dynamically. The sequence of 1SSF expansion motions in the SiC MOSFETs was observed at a high resolution of 1 s in x-ray topographies, which is sufficient to analyze the dislocation glide velocity of a 1SSF expansion. The observation results of changing the forward current density applied to the body diodes in SiC MOSFETs revealed that each triangular and bar-shaped 1SSF expands at different forward current densities. The 1SSF expansion timings also differed, even in the same chip under the same current density. The dislocation glide velocity of each expanded 1SSF in SiC MOSFETs was extracted, and it increased with the forward current density. Our method enables the dynamic visualization of bipolar degradation in SiC MOSFETs during their operations, and we can accurately obtain the information of when, where, and which 1SSF expands in a SiC MOSFET.
15 November 2017 in Japanese Journal of Applied Physics
We investigated 4H-SiC trench junction barrier Schottky (JBS) diodes from the viewpoints of the tradeoff between the electric field at the Schottky contact interface ( E s ) and the forward voltage drop, the effect on reduction of reverse leakage current, and the device yield. By calculating E s , we found that the trench JBS structure can make E s one order of magnitude smaller than that of the planar JBS structure, when the bevel angle (θ) is set between 80 and 90°. Moreover, 600 V/50 A trench JBS diodes were fabricated, and their reverse leakage current at 600 V was made 10 2 times smaller than that of the planar JBS diode by effectively reducing E s . We also found that this reduction in reverse leakage current decreases the number of low breakdown voltage samples below 600 V and improves the yield.