Muhammet Atasoy

Muhammet Atasoy

Auto-generated profile, based on publicly available information

Muhammet Atasoy

Muğla Sıtkı Koçman University Muğla Vocational School Chemistry and Chemical Treatment Technologies Department Chemistry Technology Program 48000 Muğla Turkey

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2023 in ACS Omega
Verified
Journal Article
Open access
Muradiye ŞahinMuradiye Şahin
Muradiye Şahin
MAMuhammet Atasoy
Muhammet Atasoy
YAYasin Arslan
Yasin Arslan
DYDilek Yildiz
Dilek Yildiz
The intake of heavy metals into the body, even at very low concentrations, may cause a decrease in central nervous system functions; deterioration of blood composition; and liver, kidney, and lung damage. Therefore, heavy metal ions must be removed from water. In this study, silver, magnetic iron/copper, and iron oxide nanoparticles were synthesized using Lathyrus brachypterus extract and then Fe/Cu-AT, Fe3O4-AT, Fe/Cu-CS, and Fe3O4-CS magnetic nanocomposite beads were synthesized using alginate and chitosan. The removal of Cd(II), Pb(II), Ni(II), and Cu(II) ions from aqueous phases using synthesized nanoadsorbents was investigated by single and competitive (double and quaternary) adsorption techniques. The kinetic usability of the magnetic iron oxide chitosan (Fe3O4-CS) nanocomposite beads with the highest removal efficiency was evaluated. Based on experimental results, the order of removal was found to be 98.39, 75.52, 51.54, and 45.34%, and it was listed as Pb(II) > Cu(II) > Cd(II) > Ni(II), respectively. The Dubinin-Radushkevich, Freundlich, Langmuir, and Temkin isotherm models were used, and experimental results revealed that the experimental data fit the Langmuir model better. The maximum adsorption capacities (qm) obtained from the Langmuir isotherm model of Fe3O4-CS were found to be 8.71, 23.75, 18.57, and 12.38 mg/g for Ni(II), Pb(II), Cu(II), and Cd(II) ions, respectively. When the kinetic data were applied to the Lagergren, Ho-McKay, and Elovich models, it was observed that the adsorption kinetics mostly conformed to the Ho-McKay second-order rate equation. The binary and quaternary competitive adsorption data showed that Fe3O4-CS were selective toward Cu(II) and Pb(II). The reusability of the Fe3O4-CS nanoadsorbent was performed as three cycles with the same concentration. The adsorption capacities were found to be 95.81, 70.65, 50.50, and 42.75%, in turn for Pb(II), Cu(II), Cd(II), and Ni(II) ions after three cycles, which revealed that the Fe3O4-CS nanoadsorbent can be used after three cycles without losing its efficiency.

8 September 2022 in Food Chemistry
Verified
Journal Article
Closed access
MAMuhammet Atasoy
Muhammet Atasoy
DYDilek Yildiz
Dilek Yildiz
IKİbRahim Kula
İbRahim Kula
AVAli İmran Vaizoğullar
Ali İmran Vaizoğullar


9 June 2023 in ACS Omega
Verified
Journal Article
Open access
MAMuhammet Atasoy
Muhammet Atasoy
A novel very sensitive and rapid analytical method was improved where gaseous lead formed was transported to and trapped on an externally heated platinum-coated tungsten-coil atom trap for in situ preconcentration. The analytical performance of the developed method with the graphite furnace atomic absorption spectrometry (GFAAS) method was compared. All critical parameters affecting the performance of both methods were optimized. The limit of quantitation (LOQ) was found as 11.0 ng L–1 and the precision was 2.3% in terms of percent relative standard deviation (RSD%). Characteristic concentration (Co) of the developed trap method was indicating a 32.5-fold enhancement in sensitivity compared to the GFAAS method. In order to investigate the surface morphology of the W-coil, scanning electron microscope–energy-dispersive X-ray (SEM-EDS) analyzes were performed. The accuracy of the trap method was tested by certified reference materials: NIST SRM 1640a (the elements in natural water) and DOLT:5 (dogfish liver). Interferences from other hydride-forming elements were investigated. Application of the trap method was demonstrated by the analysis of some drinking water and fish tissue samples. The t test was applied to drinking water samples, and the results indicated that there was no statistically significant error.

13 February 2023 in ACS Omega
Verified
Journal Article
Open access
HKHüseyin Karababa
Hüseyin Karababa
MAMuhammet Atasoy
Muhammet Atasoy
DYDilek Yildiz
Dilek Yildiz
IKİbrahim Kula
İbrahim Kula
MTMustafa Tuzen
Mustafa Tuzen
A sensitive and robust trap method was developed for the determination of cadmium (Cd) by using a slotted quartz tube. Using this method at a sample suction rate of 7.4 mL/min for 4.0 min collection, a 1467-fold increase in sensitivity was obtained compared to the flame atomic absorption spectrometry method. Under the optimized conditions, a limit of detection of 0.075 ng mL-1 was obtained for the trap method. The interference effects of hydride-forming elements, transition metals, and some anions on the Cd signal were investigated. The developed method was evaluated by analyzing "Sewage Sludge-industrial origin (BCR no: 146R)", "NIST SRM 1640a Trace elements in natural water", and "DOLT: 5 Dogfish Liver". There was a good agreement between the certified and found values at the 95% confidence level. This method was applied successfully for the determination of Cd in drinking water and some fish tissue samples (liver, muscle, and gill) obtained from Muğla province.

3 May 2022 in Analytical Letters
Verified
Journal Article
Closed access
DYDilek Yildiz
Dilek Yildiz
MAMuhammet Atasoy
Muhammet Atasoy
ADAhmet Demirak
Ahmet Demirak
A simple, rapid, and sensitive method for the determination of ultra-trace arsenic (III) is reported based on in situ trapping and revolatilization on a platinum (Pt) coated tungsten (W) coil atom trap. First, the analyte species in vapor form were transported by a mixture of Ar and H2 and trapped on the Pt-coated W-coil heated at 60 °C. Next, in the releasing step, the trap was resistively heated to 950 °C; the analyte species are revolatilized and transported to the quartz tube atomizer. The NaBH4 concentration, NaOH concentration, HCl concentration, trapping and releasing temperature, trapping time, and hydrogen and argon gas flow rates were optimized. Using these conditions, a limit of detection of 16 ng L−1 was obtained. The precision was evaluated by relative standard deviation corresponding to 4.8% at 1.0 μg L−1 (n = 11). The surface of the W-coil trap was coated with Pt using electrolytic deposition. Scanning electron microscopy-energy dispersive X- ray (SEM-EDX) analyses were performed to control the surface morphology of the trap. The same trap may be used for at least 350 atomization cycles without losing sensitivity. The accuracy of the proposed method was evaluated by analyzing NIST CRM 1640a (Trace Elements in Natural Water), EnviroMAT (Drinking water), and CRM-023 (Sandy Loam 7) certified reference materials. The measurements of the certified reference materials were in good agreement with the certified values at the 95% confidence level. The developed method was applied to the determination of As in drinking water samples from Muğla province.