Background. Prostate biopsy remains an important surgical procedure in the diagnostic pathway for prostate cancer, but access to prostate biopsy service is poorly studied in the Nigerian population. While there has been a well-documented delay in patient presentation with prostate cancer in Nigeria, little is however known about how long patients wait to have a histological diagnosis of prostate cancer and start treatment after presenting at Nigerian hospitals. Method. This was a descriptive retrospective study to document the specific duration of the various timelines in getting a diagnosis of prostate cancer at the Lagos State University Teaching Hospital, Ikeja, Nigeria. Results. There were 270 patients. The mean age was (range 45-90). The mean PSA at presentation was (range 2.05-15400), and the median PSA was 49.3 ng/ml. The median waiting times were (i) 10 days from referral to presentation; (ii) 30 days from presentation to biopsy; (iii) 24 days from biopsy to review of histology; (iv) 1 day from histology review to discussion/planning of treatment. The median overall waiting time from referral to treatment was 103 days. The mean time from presentation to biopsy was significantly shorter for patients with PSA of ≥50 ng/ml compared to those with . . Overall, the median time from biopsy to histology was significantly shorter for patients whose specimens were processed in private laboratories (17 days) compared to those whose specimens were processed at the teaching hospital laboratory (30 days), . Conclusion. There is a significant delay within the health care system in getting a prostate cancer diagnosis in the Nigerian population studied. The major points of the identified delay were the waiting time from patient presentation to having a biopsy done and the histology report waiting time.
Radiotherapy calibration for precise dose delivery traditionally relies on water phantom systems, but this approach poses challenges of heterogeneous corrections or the use of anthropomorphic phantoms which most underdeveloped nations find expensive. In this study, the suitability of some tissue simulating materials were investigated within the Co-60 photons energy range. This study explores the identification of locally sourced materials to simulate human tissue behavior in Co-60 energy beams. By considering effective atomic numbers and physical densities, we evaluate materials for simulating soft tissue, lung, and bone. Water, aluminum metal, and polystyrene (Styrofoam) were selected for simulating soft tissue, bone, and lung, respectively, as they have values 7.96 and 1.00 g/cm3; 13.00 and 2.6989 g/cm3 ; and 6.01 and 0.016 g/cm3 respectively for their effective atomic numbers and densites. This research provides valuable insights for resource-constrained regions aiming to improve radiotherapy calibration methods.