Omar A. Mownah

Omar A. Mownah

Auto-generated profile, based on publicly available information

Omar A. Mownah

Department of HPB Surgery, Royal London Hospital, London, UK

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Journal of Surgical Research
Verified
Journal Article
Closed access
OMOmar A. Mownah
Omar A. Mownah
MKMuhammad A. Khurram
Muhammad A. Khurram
CRChristopher Ray
Christopher Ray
AKAditya Kanwar
Aditya Kanwar
SSSusan Stamp
Susan Stamp
DTDavid Talbot
David Talbot

16 December 2011 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Closed access
PDF file
BSB. Stenberg
B. Stenberg
DTD. Talbot
D. Talbot
MKM. Khurram
M. Khurram
AKA. Kanwar
A. Kanwar
CRC. Ray
C. Ray
SES. Elliott
S. Elliott
Ziel: Diese Pilotstudie hat das Ziel, die Durchführbarkeit des kontrastverstärkten Ultraschalls (CEUS) in Nierentransplantaten zu bewerten, die sich vor Transplantation an hypothermen Perfusionsmaschinen befinden. Wir beurteilen die renale Durchblutung der Maschinen-perfundierten porcinen Nieren mit CEUS (Mastricht-Kategorie II). Material und Methoden: 5 Nieren wurden bis zu 24 h nach Ankunft an die hypotherme Maschinenperfusion angeschlossen. Die Nieren wurden dann mit einer Niedrig-MI-kontrastspezifischen Voreinstellung gescannt und ein Bolus von 0,5 ml Sonovue-Kontrastmittel wurde verabreicht. Die kontrastspezifischen Ultraschallbilder wurden in 2-D und 3-D aufgenommen. Ergebnisse: An der Perfusionsmaschine zeigten die 5 Nieren variable Flussraten (10 – 37 ml/min bei 30 mmHg). Die CEUS-Technik stellte in 4 Nieren gute Perfusion und Strömungsprofile dar, die den in vivo gesehenen entsprachen. Eine Niere hatte bis zur interlobären Region durchgängige Arterien, aber keine Kontrastfüllung in Rinde oder Mark. Kleine Perfusionsdefekte wurden in 2 der perfundierten Nieren gesehen. Schlussfolgerung: CEUS scheint eine brauchbare Methode zur Bestimmung der globalen Perfusion und kleiner Defekte in Nieren vor Transplantation zu sein. Die Flussmuster in vitro scheinen denen in vivo zu entsprechen und es ist noch weitere Arbeit erforderlich, um die Relevanz der gemessenen Durchflussdynamiken zu bewerten. Purpose: This pilot study aims to assess the viability of using contrast-enhanced ultrasound (CEUS) in renal grafts while they are on hypothermic perfusion machines prior to transplantation. We assessed the vascularity and renal perfusion of machine-perfused porcine kidneys (Maastricht category II) using CEUS. Materials and Methods: Five kidneys were placed on hypothermic machine perfusion for up to 24 hours after retrieval. The kidneys were then scanned with a low MI contrast-specific preset and a bolus of 0.5ml of Sonovue contrast agent was administered. Contrast-specific ultrasound images of the kidney were acquired in 2D and 3D. Results: The five kidneys demonstrated variable flow rates on the perfusion machine (10 – 37 ml/min at 30 mmHg). The CEUS technique demonstrated good perfusion and flow patterns, similar to those seen in vivo, in four kidneys. One kidney had patent arteries up to the interlobar region but no contrast filling in the cortex or medulla. Small perfusion defects were seen in two of the perfused kidneys. Conclusion: CEUS appears to be a viable technique for assessing global perfusion and small defects within kidneys prior to transplantation. The flow patterns seen in vitro appear to correspond to those seen in vivo. Further work is required to evaluate the relevance of the flow dynamics measured.

25 September 2025 in Annals of Surgery
Verified
Journal Article
Closed access
PLPeter Lawrence Zaki Labib
Peter Lawrence Zaki Labib
SMSiobhan C. McKay
Siobhan C. McKay
SPStéphanie F. Perrodin
Stéphanie F. Perrodin
LBLouisa Bolm
Louisa Bolm
OMOmar A. Mownah
Omar A. Mownah
KRKeith J Roberts
Keith J Roberts
Objective: Assess anticoagulation practice and portal vein thrombosis (PVT) risk following pancreaticoduodenectomy (PD) or total pancreatectomy (TP) with venous resection (VR). Background: Retrospective studies suggest an increased risk of PVT following PD/TP with VR. However, anticoagulation practice is variable and its efficacy at preventing PVT is unknown. Methods: This multicentre cohort study (Europe, USA, Mexico, Turkey, Australia, New Zealand) included consecutive patients undergoing PD/TP with VR between 2018-2022. A 1:1 age and sex matched cohort undergoing PD/TP without VR was also collected to assess PVT risk without VR. Results: Among 972 patients who underwent PD/TP with VR, 259 (26.6%) received inpatient therapeutic anticoagulation and 242 (25.0%) were discharged on therapeutic anticoagulation. Thirty-day, 90-day and one-year PVT risk following VR was 5.1%, 7.3%, and 11.6%, versus 1.0%, 1.3% and 2.6% in patients without VR (P<0.001). Predictors of 90-day PVT included prior history of venous thromboembolism (odds ratio [OR] 2.67), VR type (OR 2.29, 6.28, 6.90 and 23.75 for type 1-4 VR, P<0.001) and graft material (OR 0.78, 0.94, 5.28, 4.90 and 5.99 for peritoneal, autologous vein, cadaveric vein, bovine and synthetic grafts, P<0.001). Postoperative therapeutic anticoagulation reduced 30-day PVT risk (OR 0.06, P90-day PVT risk (OR 1.23, P=0.466). The strongest predictor of >90-day PVT was cancer recurrence (OR 3.96, P<0.001). Conclusions: VR increases PVT risk following PD/TP, with technical factors influencing 90-day PVT. The benefits of early postoperative anticoagulation in preventing PVT post-VR remain unclear.

1 July 2013 in The Annals of The Royal College of Surgeons of England
Verified
Journal Article
Open access
OMOa Mownah
Oa Mownah
TDT Dosani
T Dosani
CWC Wilson
C Wilson
HWH Wyrley-Birch
H Wyrley-Birch
DTD Talbot
D Talbot
Affiliated to the Association of Surgeons in Training and the British Transplantation Society, the Carrel Club is the transplant trainee surgical society. The Carrel Club held a joint meeting with the Chapter of Transplant Surgeons, a subsidiary organisation of the British Transplantation Society, at the Manchester Hilton Hotel on 31 January and 1 February 2013. As part of the meeting, ten abstracts were presented. A selection is printed below. The winner of the Best Presentation award was Mr Mownah.

1 January 2010 in World Journal of Gastrointestinal Surgery
Verified
Journal Article
Open access
OMOmar A Mownah
Omar A Mownah
We report on a case of an 85-year old man with an unusual presentation of small bowel obstruction. A palpable mass on digital rectal examination was subsequently visualised endoscopically with the appearance of a haematoma. The presence of a rectal mass as a presenting sign for small bowel obstruction is highly unusual and unreported in the literature.