Víctor H. Elvira

Víctor H. Elvira

Auto-generated profile, based on publicly available information

Víctor H. Elvira

Université Paris‐Saclay, CEA, LIST, Laboratoire National Henri Becquerel (LNE‐LNHB) Palaiseau France

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
MSMario Santoro
Mario Santoro
MAM.J. Anagnostakis
M.J. Anagnostakis
TBT. Boshkova
T. Boshkova
Antonio CamachoAntonio Camacho
Antonio Camacho
MIM.C. Fornaciari Iljadica
M.C. Fornaciari Iljadica
BZBenjamin Zorko
Benjamin Zorko
The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

30 November 2022 in X-Ray Spectrometry
Verified
Journal Article
Open access
VEVíctor H. Elvira
Víctor H. Elvira
MLMarie‐Christine Lépy
Marie‐Christine Lépy
YMYves Ménesguen
Yves Ménesguen
The electrical‐substitution cryogenic detector BOLometer for Use in the range of X‐rays (BOLUX) , which was developed some years ago at CEA/DAM, has been set up and restarted now at LNHB. It has been used for the primary measurement of the intensity (total energy per unit time) of monochromatic synchrotron beams in the energy range from 3 to 30 keV. These well‐determined photon beams have been employed for the efficiency calibration of two photodiodes in terms of current induced per unit optical power at different photon energies. In a final step, we explored the possibility to use these primary‐calibrated photodiodes to determine the efficiency curve of an energy‐dispersive spectrometer based on a semiconductor detector (Silicon Drift Detector) using less intense monochromatic photon fluxes. The characteristics of the radiometer BOLUX and its principle of operation are described, and the measurements carried out at the synchrotron beamline are presented, including the determination of the beams' intensities, the direct calibration of photodiodes with respect to BOLUX and the use of one of those photodiodes as a standard transfer for the calibration of the SDD.

1 June 2020 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
VEV.H. Elvira
V.H. Elvira
VPV. Peyrés
V. Peyrés
MRM. Roteta
M. Roteta
AFAlba María Fernández-Sotillo
Alba María Fernández-Sotillo
EGE. García-Toraño
E. García-Toraño

1 October 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
VEV. H. Elvira
V. H. Elvira
MRM. Roteta
M. Roteta
AFAlba María Fernández-Sotillo
Alba María Fernández-Sotillo
EGE. García-Toraño
E. García-Toraño
We recently presented the construction of a proportional counter for the absolute measurement of low-energy x-ray emission rates. Its main features were presented in a previous study, along with the testing of its performance as an absolute technique. Full details on its design, construction, and characterization processes are given in this paper. First, the analytical calculations and Monte Carlo simulations that led to the choice of optimal dimensions will be presented, followed by the study of the charge creation and the modeling of the electric field that confirmed that the criteria for a reproducible charge multiplication are met. Afterward, details on the electronics and gas control system will be provided. The dimensional measurements for the accurate determination of the solid angle will be described in detail. Special emphasis will be placed on the production of the detector window, which was made of reduced graphene oxide instead of beryllium. Some tests on the operation of the counter will be presented, namely, the measurement of spectra of several radionuclides that emit x-rays between 3 keV and 9 keV, as well as the fluorescence spectrum of chlorine, at 2.6 keV. A brief explanation of the determination of emission rates will be given, including the approach adopted for the treatment of the escape-peak area. The emission rate measured with the proportional counter was converted into activity concentration using the emission probabilities from the bibliography, in order to compare the results with those obtained by liquid scintillation counting, and both results were found to be in good agreement.