Wenyan Qian

Wenyan Qian

Auto-generated profile, based on publicly available information

Wenyan Qian

School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210023, China

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SYShuqin Yang
Shuqin Yang
LXLi Xing
Li Xing
WLWenhui Liu
Wenhui Liu
Weixing QianWeixing Qian
Weixing Qian
WQWenyan Qian
Wenyan Qian
YZYiqing Zhu
Yiqing Zhu
When the wearer of Wearable Human-Machine Interaction System (WHMIS) is talking a strenuous walk, the Inertial Measurement Units (IMUs) installed on the extremities are likely to be beyond the range of design specification of the IMU sensors. This overrange leads to poor navigation performances of the system. To overcome the problem, this paper proposes a deep learning-based method to realize robust autonomous navigation. Specifically, the Faster Region-Convolutional Neural Network (R-CNN) is built to recognize the gait types of the wearer. For each gait type, the inertial data of the wearer's thigh and the foot are collected at the same frequency as the training samples, and then used to construct a correspondent Gated Recurrent Unit-Support Vector Regression (GRU-SVR) deep hybrid neural network model for virtual IMU simulation. Then, the virtual foot-mounted IMU will be constructed in real-time by the physical thigh-mounted IMU based on the neural network models mentioned above. Once the over-range of the physical foot-mounted IMU is detected, the virtual foot inertial information will be used to reconstruct the WHMIS navigation system. Experimental results show that the proposed navigation method has the ability of fault tolerance in complex gaits, and the 3D positioning performance of the reconstructed navigation system is approximately equivalent to that of the fault-free WHMIS navigation system.

13 August 1995 in Proceedings, annual meeting, Electron Microscopy Society of America
Verified
Journal Article
Closed access
XZX. Zhang
X. Zhang
JSJohn Spence
John Spence
WQW. Qian
W. Qian
DTD. Taylor
D. Taylor
KTK. Taylor
K. Taylor
Experimental point-projection shadow microscope (PPM) images of uncoated, unstained purple membrane (PM, bacteriorhodopsin, a membrane protein from Halobacterium holobium) were obtained recently using 100 volt electrons. The membrane thickness is about 5 nm and the hexagonal unit cell dimension 6 nm. The images show contrast around the edges of small holes, as shown in figure 1. The interior of the film is opaque. Since the inelastic mean free path for 100V electrons in carbon (about 6 Å) is much less than the sample thickness, the question arises that how much, if any, transmission of elastically scattered electrons occurs. A large inelastic contribution is also expected, attenuated by the reduced detection efficiency of the channel plate at low energies. Quantitative experiments using an energy-loss spectrometer are planned. Recently Shedd has shown that at about 100V contrast in PPM images of thin gold films can be explained as Fresnel interference effects between different pinholes in the film, separated by less than the coherence width.