Thomas Gerber

Thomas Gerber

Auto-generated profile, based on publicly available information

Thomas Gerber

Paul Scherrer Institute, 5232 Villigen, Switzerland

Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2009 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MJMelanie Johnson
Melanie Johnson
ABAndras Bodi
Andras Bodi
LSLothar Schulz
Lothar Schulz
TGThomas Gerber
Thomas Gerber

1 March 2009 in Review of Scientific Instruments
Verified
Journal Article
Closed access
ABAndras Bodi
Andras Bodi
MJMelanie Johnson
Melanie Johnson
TGThomas Gerber
Thomas Gerber
ZGZsolt Gengeliczki
Zsolt Gengeliczki
BSBálint Sztáray
Bálint Sztáray
TBTomas Baer
Tomas Baer
An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal for the ion time-of-flight analysis. The ions are accelerated in a relatively low, 40–80 V cm−1 field, which enables the direct measurement of rate constants in the 103–107 s−1 range. All electron and ion events are recorded in a triggerless multiple-start/multiple-stop setup, which makes it possible to carry out coincidence experiments at >100 kHz event frequencies. As examples, the threshold photoelectron spectrum of the argon dimer and the breakdown diagrams for hydrogen atom loss in room temperature methane and the chlorine atom loss in cold chlorobenzene are shown and discussed.

29 June 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
PHPatrick Hemberger
Patrick Hemberger
VCVictoria B. F. Custodis
Victoria B. F. Custodis
ABAndras Bodi
Andras Bodi
TGThomas Gerber
Thomas Gerber
JBJeroen A. van Bokhoven
Jeroen A. van Bokhoven
Catalytic fast pyrolysis is a promising way to convert lignin into fine chemicals and fuels, but current approaches lack selectivity and yield unsatisfactory conversion. Understanding the pyrolysis reaction mechanism at the molecular level may help to make this sustainable process more economic. Reactive intermediates are responsible for product branching and hold the key to unveiling these mechanisms, but are notoriously difficult to detect isomer-selectively. Here, we investigate the catalytic pyrolysis of guaiacol, a lignin model compound, using photoelectron photoion coincidence spectroscopy with synchrotron radiation, which allows for isomer-selective detection of reactive intermediates. In combination with ambient pressure pyrolysis, we identify fulvenone as the central reactive intermediate, generated by catalytic demethylation to catechol and subsequent dehydration. The fulvenone ketene is responsible for the phenol formation. This technique may open unique opportunities for isomer-resolved probing in catalysis, and holds the potential for achieving a mechanistic understanding of complex, real-life catalytic processes.

1 August 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ABAndras Bodi
Andras Bodi
PHPatrick Hemberger
Patrick Hemberger
TGThomas Gerber
Thomas Gerber
BSBálint Sztáray
Bálint Sztáray
The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i2PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 105 s−1. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF4 indicates a dissociation mechanism change in the Franck–Condon allowed energy range of the first ion state.

1 August 2007 in Review of Scientific Instruments
Verified
Journal Article
Closed access
ABAndras Bodi
Andras Bodi
BSBálint Sztáray
Bálint Sztáray
TBTomas Baer
Tomas Baer
MJMelanie Johnson
Melanie Johnson
TGThomas Gerber
Thomas Gerber
Three data acquisition schemes for two-particle coincidence experiments with a continuous source are discussed. The single-start/single-stop technique, implemented with a time-to-pulse-height converter, results in a complicated spectrum and breaks down severely at high count rates. The single-start/multiple-stop setup, based on a time-to-digital converter and the first choice in today’s similar coincidence experiments, performs significantly better at high count rates, but its performance is still hampered if the time-of-flight range is large, and the false coincidence background is variable if the event frequency and the collection efficiency of the starts are both high. A straightforward, multistart/multistop setup is proposed for coincidence experiments. By collecting all detector data, it ensures the highest signal-to-noise ratio, constant background, and fast data acquisition and can now be easily constructed with commercially available time-to-digital converters. Analytical and numerically evaluated formulas are derived to characterize the performance of each setup in a variety of environments. Computer simulated spectra are presented to illustrate the analytically predicted features of the various raw time-of-flight distributions obtained with each technique.

8 June 2017 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
BSBálint Sztáray
Bálint Sztáray
KVKrisztina Voronova
Krisztina Voronova
KTKrisztián G. Torma
Krisztián G. Torma
KCKyle J. Covert
Kyle J. Covert
ABAndras Bodi
Andras Bodi
DODavid L. Osborn
David L. Osborn
Photoelectron photoion coincidence (PEPICO) spectroscopy could become a powerful tool for the time-resolved study of multi-channel gas phase chemical reactions. Toward this goal, we have designed and tested electron and ion optics that form the core of a new PEPICO spectrometer, utilizing simultaneous velocity map imaging for both cations and electrons, while also achieving good cation mass resolution through space focusing. These optics are combined with a side-sampled, slow-flow chemical reactor for photolytic initiation of gas-phase chemical reactions. Together with a recent advance that dramatically increases the dynamic range in PEPICO spectroscopy [D. L. Osborn et al., J. Chem. Phys. 145, 164202 (2016)], the design described here demonstrates a complete prototype spectrometer and reactor interface to carry out time-resolved experiments. Combining dual velocity map imaging with cation space focusing yields tightly focused photoion images for translationally cold neutrals, while offering good mass resolution for thermal samples as well. The flexible optics design incorporates linear electric fields in the ionization region, surrounded by dual curved electric fields for velocity map imaging of ions and electrons. Furthermore, the design allows for a long extraction stage, which makes this the first PEPICO experiment to combine ion imaging with the unimolecular dissociation rate constant measurements of cations to detect and account for kinetic shifts. Four examples are shown to illustrate some capabilities of this new design. We recorded the threshold photoelectron spectrum of the propargyl and the iodomethyl radicals. While the former agrees well with a literature threshold photoelectron spectrum, we have succeeded in resolving the previously unobserved vibrational structure in the latter. We have also measured the bimolecular rate constant of the CH2I + O2 reaction and observed its product, the smallest Criegee intermediate, CH2OO. Finally, the second dissociative photoionization step of iodocyclohexane ions, the loss of ethylene from the cyclohexyl cation, is slow at threshold, as illustrated by the asymmetric threshold photoionization time-of-flight distributions.