1 November 2020 in IET Science, Measurement & Technology
GMGorla Durga Pawan Mahidhar
Gorla Durga Pawan Mahidhar
AKAmizhtan Somasundaram Karthikeyan
Amizhtan Somasundaram Karthikeyan
The dielectric properties of 20% synthetic ester oil mixed with mineral oil were studied for its potential applications as an insulator in transformers. The corona inception voltage of mixed oil under AC and DC voltages was measured by the ultra-high frequency (UHF) technique. A statistical study of the breakdown voltage of mixed oil under AC, DC and standard lightning impulse voltages was carried out to obtain a database which would be useful for designing transformer insulation. Further, the mixture was subjected to continuous breakdown studies under AC voltage with lightning impulse voltages, at regular intervals and characterised through measurement of interfacial tension, flash point, ionic mobility as well as UV–vis spectroscopy and frequency-domain spectroscopy studies to understand the liquid's chemical stability. The results of the study have shown that the mixture was stable even after several breakdowns. The ionic mobility and polarisation current have increased, indicating higher losses in the oil. UHF signal energy analysis and phase-resolved partial discharge analysis have revealed a reduction in discharge activity with mixed oils.
9 May 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
This work reports an experimental and theoretical analysis of the rheological properties of mineral oil-based SiO 2 nanofluid for their potential applications in transformer insulation. The flow electrification mechanism on the nanofluids with different surfactants such as cetyl trimethyl ammonium bromide (CTAB), oleic acid, and Span 80 is studied using a spinning disk technique. The results show a higher streaming current for the nanofluids with CTAB as a surfactant compared to oleic acid and Span 80. The rheological behavior of nanofluids is explored with the double gap concentric cylinder geometry. The variation of shear stress with shear rate follows a power law relationship along with a yield stress observed for all the nanofluids. A transition is seen from storage modulus to dominant loss modulus for the nanofluids during the frequency sweep analysis, whereas no transition is observed in the case of mineral oil. In addition, regression analysis using artificial neural network (ANN) algorithms are performed on the experimentally measured viscosity of the nanofluids in order to estimate theoretical parameters and provide insights into the streaming current formation. The desirable rheological characteristics of nanofluids are identified for achieving enhanced insulation performance in transformers.
1 October 2016 in Journal of Electrostatics
2 May 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
This paper reports an experimental investigation of the impact of magnetic field on corona discharge activity in mineral oil, using both ultra-high frequency (UHF) and fluorescence techniques under AC voltage. The results show that corona inception voltage (CIV) increased under AC voltage with varying harmonic frequencies without considering any phase shift and reduced marginally under magnetic field. In addition, the impact of the magnetic field shifted the dominating frequency of the UHF signal (0.9 GHz) obtained under AC voltage towards lower frequencies (0.3 GHz and 0.6 GHz). Under high magnetic fields, the parameters such as rise time, fall time and pulse width of the fluorescence signal increased in its magnitude compared to its effect without magnetic field. Also, using both the UHF sensor and the fluorescence sensor, there was no clear difference in the phase resolved partial discharge (PRPD) pattern caused by corona discharge (with and without magnetic field). Further, the number of discharges is observed to be high under the impact of harmonic AC voltages with third and seventh order containing total harmonic distortions (THD) of 4% and 40%.
20 December 2020 in IET Science, Measurement & Technology
AKAmizhtan Somasundaram Karthikeyan
Amizhtan Somasundaram Karthikeyan
GMGorla Durga Pawan Mahidhar
Gorla Durga Pawan Mahidhar
The proposed study compares the electrical, thermal and mechanical performances of thermally aged cellulose pressboard material impregnated in mineral oil, synthetic ester fluid and mixed oil. The electrical insulation characteristics of oil-impregnated pressboard (OIP) are studied by means of surface discharge inception voltage (SDIV) using an ultra-high frequency technique and surface potential measurement analysis. It indicates that OIP aged in mineral oil has higher surface potential due to higher charge trap density compared to that of the mixed oil and synthetic ester fluid. Mechanical and thermal characteristics of the aged OIP are studied by means of tensile strength measurement and thermo-gravimetric analysis, respectively. The change in the chemical composition of OIP is studied by means of laser-induced breakdown spectroscopy, which indicates lower plasma temperature with mineral oil-based OIP indicating higher degradation state. To further understand the microscopic structure of the thermally aged OIP in different oils, scanning electron microscopy and X-ray diffraction studies have been performed. The pressboard thermally aged in synthetic ester fluid and the mixed oil has better electrical, thermal and mechanical properties as compared with the pressboard aged in mineral oil.
11 August 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
This work deals with the effect of oil reclamation on the conduction mechanism and dielectric aspects of accelerated thermally aged transformer mineral oil. The reclamation is a treatment with fuller’s earth adsorbent to remove corrosive sulphur compounds and other contaminants formed during the thermal ageing. Properties of the oil are compared between different stages of the treatment. Corona (partial discharge) inception is identified by the optical fluorescent fiber technique. The results show an increased corona inception voltage after treatment. Dielectric response spectroscopy (DRS) showed lower loss factor and electrical conductivity after treatment. Conduction mechanism is measured under uniform and non-uniform electric field with variation in applied voltage magnitude. Conduction mechanism at a uniform electric field (low E ) is studied using the polarity reversal technique to estimate the respective ionic motilities in the fluid. The apparent mobility of ions, conductivity, ionic radius and concentration from the oil are found to reduce on reclamation. In addition, the conduction mechanism for a higher electric field is simulated by the current-voltage characteristic in non-uniform conditions and the slope determines the ionic mobility of the fluid.