2 April 2025 in IEEE Robotics and Automation Letters
The tendon-sheath mechanism (TSM) has significantly advanced both robotic systems and minimally invasive surgery (MIS) by enabling flexible and precise movement through narrow and tortuous paths. However, the inherent flexibility of TSM introduces nonlinear behaviors which depend on its geometrical shape and applied forces, making accurate control challenging. Furthermore, the shape dependency becomes critical in endoscopic robots, where the geometrical shape varies and is not directly visible, limiting the applicability of existing distal sensorless compensation methods. To address the geometry identification problem of TSM, this paper proposes an approach that utilizes real-time visual input from an endoscopic camera for on-line calibration of the TSM's physical model. By introducing the concept of the ‘Equivalent Circle,’ complex shapes of TSMs are simplified, enabling the estimation of their equivalent geometry without direct observation or measurement. Simulation results validate the equivalent circle model, demonstrating minimal deadband percentage errors despite larger discrepancies in equivalent radii across varied configurations. On-line calibration experiments achieved a percent error of 1.38% (±2.92%) for accumulated curve angles and 2.32% (±3.08%) for equivalent radii, demonstrating the method's reliability in shape estimation across varying conditions. In prediction and feedforward experiments, leveraging the equivalent circle to compensate for deadband in arbitrarily shaped TSMs resulted in a maximum trajectory error of 0.25 mm and an RMSE of 0.09 mm. This approach advances distal sensorless control, improving the operational accuracy and feasibility of endoscopic surgical robots under varying geometrical and force conditions.
23 May 2025 in IEEE Robotics and Automation Letters
Nonlinear backlash-like hysteresis in tendon-sheath mechanism based endoscopic surgical robots introduces significant motion errors, limiting precision in surgical tasks. Existing methods struggle to compensate for these errors in real time, particularly without relying on distal-end sensors. To address this challenge, we introduce novel hybrid control strategy integrating adaptive feedforward and feedback control, enabling real-time deadband compensation and disturbance rejection. Unlike conventional approaches, our method does not require distal sensors and incorporates a vision-based tracking technique inspired by medical dye techniques. Two blue markers, attached to the robot arm, are tracked in HSV color space, allowing accurate angle estimation via polynomial regression, eliminating the need for high-clarity imaging as required in conventional laparoscopic tracking methods. Not only does our method guarantee ultimate boundedness from a control-theoretic perspective, but experimental validation under simulated surgical conditions also demonstrates a 98.6% reduction in RMSE, achieving 0.025 mm tracking error, compared to no control (1.815 mm), P-control (0.374 mm), and adaptive feedforward control (0.152 mm). The system adapts rapidly to abrupt tension changes, ensuring stable and precise control. By improving control accuracy and eliminating the need for distal sensors, our method enhances the reliability of endoscopic robotic systems, contributing to safer and more precise minimally invasive surgical procedures.
25 July 2025 in The International Journal of Medical Robotics and Computer Assisted Surgery
Background: Endoscopic Retrograde Cholangiopancreatography (ERCP) and Percutaneous Coronary Intervention (PCI) are minimally invasive procedures that treat diseases with minimal scarring and rapid recovery. However, catheterisation under fluoroscopy exposes medical staff to radiation, and navigating flexible guidewires through complex anatomical pathways requires precise control.Methods: To address these challenges, we propose a novel insertion robot based on a Chebyshev lambda mechanism that makes a linear grasp path and an arc‐shaped quick return path using a single motor. An integrated roll module enables continuous insertion and rotation, yielding a robot with two degrees of freedom.Results: Experiments show robots can make sufficient insertion force for real procedures, with robot's maximum mean translational and rotational errors of 0.11 mm and 1.47°, respectively. Phantom model tests show its applicability to human anatomy.Conclusions: The proposed robotic system demonstrated sufficient precision and force for real surgical applications, indicating its potential for clinical use in minimally invasive procedures.
1 September 2026 in IEEE Robotics and Automation Letters