1 January 2016 in The International Journal of Oral and Maxillofacial Implants
Berkay Tolga Suer, DDS, PhD/Zekai Yaman, DDS, PhD/Bora Buyuksarac, MSc: Purpose: Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs and the insertion torque and resonance frequency values of mandibular implants. Materials and Methods: Thirty patients who received a total of 55 implants of the same brand, diameter, and length in the mandibular premolar and molar regions were included in the study. The same surgical procedures were applied to each patient, and the insertion torque and resonance frequency values were recorded for each implant at the time of placement. The radiographic fractal dimensions of the alveolar bone in the implant recipient area were calculated from preoperative panoramic radiographs using a box-counting algorithm. The insertion torque and resonance frequency values were compared with the fractal dimension values using the Spearman test. Results: All implants were successful, and none were lost during the follow-up period. Linear correlations were observed between the fractal dimension and resonance frequency, between the fractal dimension and insertion torque, and between resonance frequency and insertion torque. Conclusion: These results suggest that the noninvasive measurement of the fractal dimension from panoramic radiographs might help to predict the bone quality, and thus the primary stability of dental implants, before implant surgery.
1 January 2014 in Medical Dosimetry
19 April 2007 in Medical Physics
11 January 2025 in Medical & Biological Engineering & Computing
This study aims to understand the impact of backpack carriage, a regular activity for many, on back muscles and joint mobility during walking so that clinicians can develop strategies or products to ensure individuals’ safety and well-being. Surface electromyography (EMG) and XSENS Awinda motion capture systems were used to analyze the effects of carrying a backpack (12% of body weight) on erector spinae and multifidus muscles, as well as spinal, hip, knee, and ankle joints. Subjects walked at 4 km/h on flat and inclined surfaces. Paired t-tests compared backpack loads to baseline measurements. Carrying a backpack reduced activation levels in erector spinae and multifidus muscles and restricted spinal joint range of motion (axial and lateral bending, $$\varvec{p<0.05}$$ ). Hip joint rotation increased ( $$\varvec{p<0.05}$$ ). Moderate to strong correlations were observed between muscle activity and spinal joint ROM, notably with left erector spinae and L5-S1 lateral bending ( $$\varvec{r=0.723}, \varvec{p<0.001}$$ ). Backpack carriage decreases back muscle activation and alters the joint range of motion. Asymmetric correlations show that the subjects adapt muscle activity and gait patterns asymmetrically to manage external loads. Graphical
25 July 2017 in Magnetic Resonance Materials in Physics, Biology and Medicine
30 August 2025 in Frontiers in Life Sciences and Related Technologies
This study utilizes cold water consumption as a method of vagus nerve stimulation, investigating how body mass index (BMI) and repeated stimulation affect heart rate variability (HRV) in both time and frequency domains. HRV was measured in 18 subjects (mean age 21.3 ± 1.6 years) over 90 minutes, divided into three equal phases: resting (baseline), first stimulation (FSP), and second stimulation (SSP). Fourier and Short-Time Fourier Transform (STFT) analyses were used to extract the static and time-varying frequency components of HRV. For the normal body mass index (BMI) group, stimulation resulted in statistically significant changes in frequency band power densities compared to their baseline measurements (p