1 February 2019 in Annals of Nuclear Energy
1 February 2017 in Nuclear Engineering and Technology
When an integral pressurized water reactor is operated under low power conditions, once-through steam generator group operation strategy is applied. However, group operation strategy will cause nonuniform coolant flow distribution at the core inlet and lower plenum. To help coolant flow mix more uniformly, a flow mixing chamber (FMC) has been designed. In this paper, computational fluid dynamics methods have been used to investigate the coolant distribution by the effect of FMC. Velocity and temperature characteristics under different low power conditions and optimized FMC configuration have been analyzed. The results illustrate that the FMC can help improve the nonuniform coolant temperature distribution at the core inlet effectively; at the same time, the FMC will induce more resistance in the downcomer and lower plenum
9 February 2021 in Frontiers in Energy Research
In nuclear reactor system research, the multiscale coupled thermal-hydraulic (T-H) system code and CFD code is one of the most prevalent research areas, and it could help improve simulation fidelity and optimize nuclear reactor design. Additionally, a new idea known as the function fitting method (FFM) for coupling parameter distribution has been newly proposed for exchanging data on the coupling interface, which uses math equations to present the velocity distribution characteristics at the coupling interface. This method could improve the simulation error and numerical instability. To verify and validate the abovementioned FFM, a comparison between the velocity function shape by FFM and real velocity distribution was completed. Besides, the Edwards pipe blowdown test results were used to verify the coupled code. The results showed good agreement with experiment results, and a better simulation accuracy compared to previous work. The current work will establish the ability to explore multiscale coupled thermal-hydraulic operation characteristics which permit precise local parameter distribution.
27 December 2020 in Science and Technology of Nuclear Installations
Qinshan nuclear power plant is the first large Chinese-designed nuclear power station based on pressurized water reactor, and the second generation main stream active safety injection system is adopted for Qinshan nuclear power plant. In this paper, a novel passive safety injection system (PSIS) has been proposed for ocean-based Qinshan Phase One nuclear power plant to replace the original active one. The PSIS contains high-pressure, medium-pressure, and lower-pressure safety injection systems, and a two-stage automatic depressurization system. To evaluate the system performance, small-break LOCA has been investigated using RELAP5. Various break sizes and locations including 2-inch, 10-inch cold leg break, and double-ended direct vessel injection line break were analyzed. Key safety parameters such as safe injection mass flow rates, coolant level of the core, system pressure, and fuel cladding temperature were monitored during the accident process. The results illustrate that the performance of the safety injection system can guarantee the effective core cooling and submerged under different LOCA even with only half of the safety injection system, which can fulfill the single failure criteria. The thermal-hydraulic analysis for the Qinshan passive safety injection system is significant to master the related technologies for Chinese engineer and develop the Chinese-designed third-generation nuclear power plants, and the PSIS can guarantee the reactor submerged under LOCA even plus the station block out accident.
7 February 2019 in Annals of Nuclear Energy
16 July 2021 in Frontiers in Energy Research
In this work, a brand new passive safety injection system has been designed for the ocean-based Qinshan Phase I nuclear power plant to update and replace the traditional active ones. The passive safety injection system is made up of high pressure, medium pressure, lower pressure safety injection system, and a two-stage automatic depressurization system. To evaluate the safety injection system performance, double-ended cold leg large break LOCA has been analyzed by best-estimated safety analysis RELAP5 code. The main operation and safety parameters such as primary system pressure, safe injection mass flow rates, core water level, and peak cladding temperature have been presented. The results conclude that the safety injection system can act as similar to that of the AP1000, which can assure sufficient core cooling and keep the reactor covered by the cold water under the most severe LBLOCA condition.