23 January 2023 in Nature Photonics
2 August 2021 in Light: Science & Applications
Focusing light into scattering media, although challenging, is highly desirable in many realms. With the invention of time-reversed ultrasonically encoded (TRUE) optical focusing, acousto-optic modulation was demonstrated as a promising guidestar mechanism for achieving noninvasive and addressable optical focusing into scattering media. Here, we report a new ultrasound-assisted technique, ultrasound-induced field perturbation optical focusing, abbreviated as UFP. Unlike in conventional TRUE optical focusing, where only the weak frequency-shifted first-order diffracted photons due to acousto-optic modulation are useful, here UFP leverages the brighter zeroth-order photons diffracted by an ultrasonic guidestar as information carriers to guide optical focusing. We find that the zeroth-order diffracted photons, although not frequency-shifted, do have a field perturbation caused by the existence of the ultrasonic guidestar. By detecting and time-reversing the differential field of the frequency-unshifted photons when the ultrasound is alternately ON and OFF, we can focus light to the position where the field perturbation occurs inside the scattering medium. We demonstrate here that UFP optical focusing has superior performance to conventional TRUE optical focusing, which benefits from the more intense zeroth-order photons. We further show that UFP optical focusing can be easily and flexibly developed into double-shot realization or even single-shot realization, which is desirable for high-speed wavefront shaping. This new method upsets conventional thinking on the utility of an ultrasonic guidestar and broadens the horizon of light control in scattering media. We hope that it provides a more efficient and flexible mechanism for implementing ultrasound-guided wavefront shaping.
18 June 2018 in Optics Letters
A fast and accurate wavefront reconstruction method for two-frame phase-shifting interferometry is proposed. The unknown phase step between the two interferograms is estimated directly by solving a quartic polynomial equation, and then the phase map is readily reconstructed after obtaining the phase step. The whole phase reconstruction process is nearly analytical and thus very fast and easy to realize. Good performance of the proposed method is demonstrated by reconstructing the phase maps from simulated and real fringes along with comparisons to several existing well-established algorithms.
16 September 2019 in Applied Physics Letters
Random two-frame phase-shifting interferometry (PSI) is an advanced technique to retrieve the phase information from as few as two interferograms with unknown phase steps. Because of the advantages of no requirement for accurate phase shifters and much less time for data acquisition and processing, random two-frame PSI is attracting more and more interest in fast and high-precision optical metrology. However, reconstructing the phase from only two interferograms is challenging because it is an ill-posed problem in essence, especially when the phase step is unknown. Although some solutions have been proposed for this problem to date, most of them require complicated preprocessing or special usage preconditions for interferograms to be demodulated. In this letter, we developed an elegant phase reconstruction method for random two-frame PSI, which is much different from frameworks of existing methods. In the proposed approach, the phase of random two-frame PSI can be accurately reconstructed using the phase step value which minimizes the coefficient of variation (CV) of the modulation term of interferograms. Sufficient numerical simulations and experimental data demonstrate the high accuracy and high efficiency of this CV minimization (CVM) method. Moreover, its performance is not limited by the number of fringes in interferograms, in contrast to existing state-of-the-art approaches. We anticipate extensive applications of the CVM method in random two-frame PSI in the future.
10 January 2020 in Optics Letters
Wavefront shaping (WFS) based on digital optical phase conjugation (DOPC) has gained major interest in focusing light through or inside scattering media. However, the quality of DOPC is greatly limited by imperfections of the system in a complicated and coupled way. In this Letter, we incorporate the concept of global optimization to solve this problem comprehensively for the first time, to the best of our knowledge. An automatic and intelligent optimization framework for DOPC techniques is proposed, leveraging the global optimization ability of particle swarm optimization (PSO). We demonstrate the general and powerful ability of the proposed approach in a series of DOPC-related experiments for focusing through and inside scattering media. This novel work can improve the OPC quality greatly and simplify the development of a high-performance DOPC system, which may open up a new avenue for the general scientific community to benefit from DOPC-based WFS in their potential applications.
29 July 2019 in Optics Letters
Self-calibrating phase-shifting interferometry (PSI) reconstructs the phase map from three-frame or more phase-shifting interferograms without the need for knowing accurate phase steps. The existing phase reconstruction methods for self-calibrating PSI still have many constraints in terms of the required number of interferograms, special usage preconditions, etc. In this Letter, a universal, accurate, and efficient phase reconstruction method for self-calibrating PSI is proposed. In this approach, we search the solution space of phase shifts to obtain the modulation amplitude of interferograms with the minimum coefficient of variation (CV). Then the phase is reconstructed through the searched phase shifts. Numerical and experimental studies demonstrate that this method can realize highly accurate phase reconstruction consistently, compared to the currently popular methods in their own usable ranges. We anticipate that this Letter may provide a universal and powerful solution for the phase reconstruction of self-calibrating PSI. (c) 2019 Optical Society of America