18 February 2008 in Metrologia
1 March 1988 in Journal of Research of the National Bureau of Standards
We report a new determination of the Universal Gas Constant R: (8.314 471 ±0.000 014) J·mol−1K−1. The uncertainty in the new value is 1.7 ppm (standard error), a factor of 5 smaller than the uncertainty in the best previous value. The gas constant was determined from measurements of the speed of sound in argon as a function of pressure at the temperature of the triple point of water. The speed of sound was measured with a spherical resonator whose volume was determined by weighing the mercury required to fill it at the temperature of the triple point. The molar mass of the argon was determined by comparing the speed of sound in it to the speed of sound in a standard sample of argon of accurately known chemical and isotoptic composition.
22 February 2019 in Metrologia
25 January 1988 in Physical Review Letters
We report a new value for the universal gas constant J . The standard error of has been reduced by a factor of 5, to 1.7 ppm. was determined from the speed of sound in argon contained within a thick, spherical shell at the temperature of the triple point of water . The volume of the shell was measured by our weighing the mercury required to fill it at . The molar mass of the argon was determined relative to that of a standard with accurately known chemical and isotopic composition by use of speed-of-sound data.
27 November 2003 in Metrologia
21 October 2004 in Metrologia