Federico Paratore

Federico Paratore

Auto-generated profile, based on publicly available information

Federico Paratore

IBM Research Europe, Rüschlikon, Switzerland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
DPDaniel Probst
Daniel Probst
MMMatteo Manica
Matteo Manica
YTYves Gaetan Nana Teukam
Yves Gaetan Nana Teukam
ACAlessandro Castrogiovanni
Alessandro Castrogiovanni
FPFederico Paratore
Federico Paratore
TLTeodoro Laino
Teodoro Laino
Enzyme catalysts are an integral part of green chemistry strategies towards a more sustainable and resource-efficient chemical synthesis. However, the use of biocatalysed reactions in retrosynthetic planning clashes with the difficulties in predicting the enzymatic activity on unreported substrates and enzyme-specific stereo- and regioselectivity. As of now, only rule-based systems support retrosynthetic planning using biocatalysis, while initial data-driven approaches are limited to forward predictions. Here, we extend the data-driven forward reaction as well as retrosynthetic pathway prediction models based on the Molecular Transformer architecture to biocatalysis. The enzymatic knowledge is learned from an extensive data set of publicly available biochemical reactions with the aid of a new class token scheme based on the enzyme commission classification number, which captures catalysis patterns among different enzymes belonging to the same hierarchy. The forward reaction prediction model (top-1 accuracy of 49.6%), the retrosynthetic pathway (top-1 single-step round-trip accuracy of 39.6%) and the curated data set are made publicly available to facilitate the adoption of enzymatic catalysis in the design of greener chemistry processes.

13 December 2021 in Nature Reviews Chemistry
Verified
Journal Article
Closed access
PDF file
FPFederico Paratore
Federico Paratore
VBVesna Bacheva
Vesna Bacheva
MBMoran Bercovici
Moran Bercovici
GKGovind Kaigala
Govind Kaigala

6 May 2021 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
EBEvgeniy Boyko
Evgeniy Boyko
VBVesna Bacheva
Vesna Bacheva
MEMichael Eigenbrod
Michael Eigenbrod
FPFederico Paratore
Federico Paratore
AGAmir D. Gat
Amir D. Gat
MBMoran Bercovici
Moran Bercovici
We demonstrate theoretically and experimentally that injection of momentum in a region surrounding an object in microscale flow can yield both “cloaking” conditions, where the flow field outside the cloaking region is unaffected by the object, and “shielding” conditions, where the hydrodynamic forces on the object are eliminated. Using field-effect electro-osmosis as a mechanism for injection of momentum, we present a theoretical framework and analytical solutions for a range of geometrical shapes, validate these both numerically and experimentally, and demonstrate the ability to dynamically switch between the different states.

27 November 2017 in ACS Sensors
Verified
Journal Article
Open access
SASofia Arshavsky-Graham
Sofia Arshavsky-Graham
NMNaama Massad-Ivanir
Naama Massad-Ivanir
FPFederico Paratore
Federico Paratore
TSThomas Scheper
Thomas Scheper
MBMoran Bercovici
Moran Bercovici
Ester SegalEster Segal
Ester Segal
Porous silicon (PSi) nanomaterials have been widely studied as label-free optical biosensors for protein detection. However, these biosensors’ performance, specifically in terms of their sensitivity (which is typically in the micromolar range), is insufficient for many applications. Herein, we present a proof-of-concept application of the electrokinetic isotachophoresis (ITP) technique for real-time preconcentration of a target protein on a PSi biosensor. With ITP, a highly concentrated target zone is delivered to the sensing area, where the protein target is captured by immobilized aptamers. The detection of the binding events is conducted in a label-free manner by reflective interferometric Fourier transformation spectroscopy (RIFTS). Up to 1000-fold enhancement in local concentration of the protein target and the biosensor’s sensitivity are achieved, with a measured limit of detection of 7.5 nM. Furthermore, the assay is successfully performed in complex media, such as bacteria lysate samples, while the selectivity of the biosensor is retained. The presented assay could be further utilized for other protein targets, and to promote the development of clinically useful PSi biosensors.

26 May 2017 in Analytical Chemistry
Verified
Journal Article
Open access
FPFederico Paratore
Federico Paratore
TKTal Zeidman Kalman
Tal Zeidman Kalman
TRTally Rosenfeld
Tally Rosenfeld
GKGovind Kaigala
Govind Kaigala
MBMoran Bercovici
Moran Bercovici
In the absence of amplification methods for proteins, the immune-detection of low-abundance proteins using antibodies is fundamentally limited by binding kinetic rates. Here, we present a new class of surface-based immunoassays in which protein–antibody reaction is accelerated by isotachophoresis (ITP). We demonstrate the use of ITP to preconcentrate and deliver target proteins to a surface decorated with specific antibodies, where effective utilization of the focused sample is achieved by modulating the driving electric field (stop-and-diffuse ITP mode) or applying a counter flow that opposes the ITP motion (counterflow ITP mode). Using enhanced green fluorescent protein (EGFP) as a model protein, we carry out an experimental optimization of the ITP-based immunoassay and demonstrate a 1300-fold improvement in limit of detection compared to a standard immunoassay, in a 6 min protein–antibody reaction. We discuss the design of buffer chemistries for other protein systems and, in concert with experiments, provide full analytical solutions for the two operation modes, elucidating the interplay between reaction, diffusion, and accumulation time scales and enabling the prediction and design of future immunoassays.

6 May 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
FPFederico Paratore
Federico Paratore
VBVesna Bacheva
Vesna Bacheva
GKGovind Kaigala
Govind Kaigala
MBMoran Bercovici
Moran Bercovici
Significance: Traditional microfluidic devices make use of physical channels and mechanical actuators, in which geometries and functionalities are intimately related to one another, i.e., changing the flow field requires change at the mechanical level. In this work, we introduce a concept in which a microfluidic chamber with no preset structures or active mechanical components can be dynamically configured to produce desired flow fields.