Traditional methods used to repair prestressed concrete (PC) girders subjected to impact damage due to overheight vehicles include strand splicing and external posttensioning. These methods have proven to be partially satisfactory in restoring the damaged girder’s ultimate strength. The use of composite materials in the strengthening, rehabilitation, and repair industry has been gaining popularity due to their excellent material behavior and ease of application. Composites such as fiber-reinforced polymer (FRP) and fabric-reinforced cementitious matrix (FRCM) systems are presently available alternatives for restoring the integrity of a damaged girder that eliminate the need for girder replacement. The use of externally bonded carbon FRP (CFRP) materials for the repair of damaged bridge components has been successfully deployed and has been shown to reduce repair costs and traffic closure time. FRCM composites represent an alternative material to FRP for structural retrofit/rehabilitation. However,...
During detailed visual inspections, inspectors on the Varina-Enon Bridge noticed a significant flexural crack opening, visually estimated at 1.5 mm under traffic, on the last span of the approach structure among other significant cracks on June 29, 2012. To investigate the causes of the observed cracking, live-load testing, long-term monitoring, and structural analysis were used including 77 total strain, crack displacement, deflection, and temperature sensors. The live-load test produced a crack opening of approximately 0.5 mm when under a less-severe thermal gradient. The collected data indicated the crack opening was greatly influenced by interaction of vehicular loads and thermal gradient magnitude. There were 389 crack openings larger than 0.0625 mm over the 17 months of the long-term monitoring, with a maximum measured crack opening of approximately 0.76 mm. Maximum measured thermal gradients were found to be in excess of the as-built design thermal gradient but similar to the current design thermal gradient. This may indicate potential underestimation of the maximum design thermal gradient, but would require a more robust study.
C7Charles D. Newhouse, P.E., M.ASCE1; Carin L. Roberts-Wollmann, P.E., M.ASCE2; Thomas E. Cousins, P.E., M.ASCE3; and Rodney T. Davis, P.E., M.ASCE41Assistant Professor, Dept. of Civil and Environmental Engineering, Texas Tech Univ., Lubbock, TX 79409.2Asso
Charles D. Newhouse, P.E., M.ASCE1; Carin L. Roberts-Wollmann, P.E., M.ASCE2; Thomas E. Cousins, P.E., M.ASCE3; and Rodney T. Davis, P.E., M.ASCE41Assistant Professor, Dept. of Civil and Environmental Engineering, Texas Tech Univ., Lubbock, TX 79409.2Asso
M.M.Asce
M.Asce
An increasing number of bridges are being designed with continuous spans instead of simple spans. By reducing the number of joints in a bridge, the traveling public receives a better riding surface and corrosion caused by leaking joints can be reduced. Also, redundancy is created when the system is made continuous, producing a tougher structure. However, a continuous system is more complicated to design and secondary restraint moments due to creep, shrinkage, and thermal effects can develop at the connection. This paper presents results from an experimental study done to monitor the early age restraint moments that develop in a two-span continuous system made of full-depth precast concrete bulb tee girders. The restraint moments observed were compared to the predicted restraint moments using the RMCalc program . The observed restraint moments were significantly lower than predicted by the program. Expansion of the deck during curing, which is generally not considered in the predictions, significantly influenced the early age restraint moments. A simplified model to predict the restraint moments considering thermal effects is proposed.
This paper presents an experimental investigation of a 64-year-old, full-scale, simply supported, prestressed bridge girder retrofitted with external posttensioning. The specific retrofit can be used to increase the flexural strength of corrosion-damaged prestressed beams. The test specimen, taken from a bridge located in Virginia, was subjected to monotonically increasing loads until the occurrence of a diagonal compression failure in the vicinity of one of the external tendon anchor blocks. The experimental test was accompanied by finite-element analyses, aimed to elucidate the failure mode and quantify the impact of the repair on the capacity of damaged beams. Simplified calculations based on strut-and-tie models and design code guidelines are found to give satisfactory estimates of the failure load, while also describing the principal aspects of the force transfer between the external tendons and the beam and the stress state in the immediate vicinity of the anchor blocks.
1 December 2016 in Journal of Performance of Constructed Facilities
Short- to medium-span composite bridges constructed with adjacent precast inverted T-beams and cast-in-place topping are intended to provide a higher degree of resistance against reflective cracking and time-dependent effects compared with voided slab and adjacent box beam systems. This paper presents the results of an analytical and experimental study performed on the first inverted T-beam bridge in Virginia. The purpose of the investigation was to quantify live-load distribution factors for shear and moment for the composite precast inverted T-beam bridge. A finite-element model of Phase I of the bridge was created and the live-load distribution factors were analytically determined. Additionally, live-load tests using a stationary truck were performed with the purpose of quantifying live-load distribution factors for moment and validating the results from the finite-element analyses. The live-load tests featured four transverse truck positions on the bridge. It is concluded that it is appropriat...