Lingrao Wang

Lingrao Wang

Auto-generated profile, based on publicly available information

Lingrao Wang

North China Branch of State Grid Corporation of China, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Wei YaoWei Yao
Wei Yao
LWLingrao Wang
Lingrao Wang
HZHong-yu Zhou
Hong-yu Zhou
YXYongxin Xiong
Yongxin Xiong
JWJinyu Wen
Jinyu Wen
Harmonics interaction is an important factor in causing concurrent commutation failures (CCF) of multiple converter stations in multi-infeed HVDC (MI-HVDC) systems, but it was not studied sufficiently in existing literature. In this paper, the mechanism analysis and quantitative calculation of harmonic interaction are investigated. Firstly, the generation and interaction process of harmonic during AC fault events in the MI-HVDC systems with single-terminal connection and hierarchical connection on receiving-end are illustrated, respectively. Then, the common characteristics of harmonic interaction in generalized MI-HVDC systems are concluded. Moreover, to evaluate the impact of harmonic interaction on commutation process quantitatively, an equivalent circuit model of harmonic transfer in MI-HVDC system is established. Based on this equivalent model, the harmonic voltage transfer coefficient is deduced, and the extinction angle of inverters considering harmonic interaction in MI-HVDC systems can be calculated. Finally, the calculation accuracy based on equivalent model is verified via the electromagnetic transient simulation of MI-HVDC system. Simulation results show that harmonic interaction will eventually cause the formation of harmonic source in each converter station of MI-HVDC systems. These harmonic components will change the extinction angle of remote inverters to increase the risk of CCFs.

27 February 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
Wei YaoWei Yao
Wei Yao
LWLingrao Wang
Lingrao Wang
YXYongxin Xiong
Yongxin Xiong
YTYangchen Tan
Yangchen Tan
DLDahu Li
Dahu Li
JWJinyu Wen
Jinyu Wen
Commutation failure (CF) is an inherent drawback of line-commutated converter high-voltage DC (LCC-HVDC) system. And CF prevention (CFPREV) control is widely applied in UHVDC lines to mitigate the subsequent CF. However, the formation of a multi-infeed UHVDC system induces power exchange and voltage interaction between AC buses during the transient process, making the behaviors and mitigation of CFs more complex. Consequently, exploring the impact of CFPREV control on adjacent stations and optimizing the CFPREV control to adapt to the interaction characteristics in a multi-infeed system is necessary. Considering the interaction characteristics, the impact of CFPREV control on the commutation process of inverters in a multi-infeed system is analyzed through formula derivation and simulation verification. It is found that although CFPREV control can effectively mitigate the CFs of the inverter near the fault, it will further increase the risk of concurrent CF (CCF) of remote inverters due to the interaction on the AC side. To solve this problem, a coordinated control scheme of CFPREV controls in a multi-infeed UHVDC system is proposed. The output of the CFPREV control of the inverter near the fault can be adjusted adaptively according to the commutation margins of remote inverters. And the probability of CCF caused by CFPREV control is consequently decreased. Case studies are conducted based on Henan provincial multi-infeed UHVDC system in China to verify the analysis result and the effectiveness of the coordinated control scheme of CFPREV controls.