Majeed M. Hayat

Majeed M. Hayat

Auto-generated profile, based on publicly available information

Majeed M. Hayat

Department of Electrical and Computer Engineering, Marquette University, Milwaukee, WI, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZWZhuoyao Wang
Zhuoyao Wang
MRMahshid Rahnamay-Naeini
Mahshid Rahnamay-Naeini
JAJoana M. Abreu
Joana M. Abreu
RSRezoan A. Shuvro
Rezoan A. Shuvro
PDPankaz Das
Pankaz Das
MHMajeed M. Hayat
Majeed M. Hayat
Human operators play a key role in the reliable operation of critical infrastructures. However, human operators may take actions that are far from optimum. This can be due to various factors affecting the operators' performance in time-sensitive and critical situations such as reacting to contingencies with significant monetary and social impacts. In this paper, an analytic framework is proposed based on Markov chains for modeling the dynamics of cascading failures in power grids. The model captures the effects of operators' behavior quantified by the probability of human error under various circumstances. In particular, the observations from historical data and information obtained from interviews with power-system operators are utilized to develop the model as well as identify its parameters. In light of the proposed model, the noncritical regions of power-system's operating characteristics with human-factor considerations are characterized under which the probability of large cascading failures is minimized.

1 October 2019
Verified
Conference Paper
Closed access
RSRezoan A. Shuvro
Rezoan A. Shuvro
PDPankaz Das
Pankaz Das
MHMajeed M. Hayat
Majeed M. Hayat
MTMitun Talukder
Mitun Talukder
Although there has been notable progress in modeling cascading failures in power grids, few works included using machine learning algorithms. In this paper, cascading failures that lead to massive blackouts in power grids are predicted and classified into no, small, and large cascades using machine learning algorithms. Cascading-failure data is generated using a cascading failure simulator framework developed earlier. The data set includes the power grid operating parameters such as loading level, level of load shedding, the capacity of the failed lines, and the topological parameters such as edge betweenness centrality and the average shortest distance for numerous combinations of two transmission line failures as features. Then several machine learning algorithms are used to classify cascading failures. Further, linear regression is used to predict the number of failed transmission lines and the amount of load shedding during a cascade based on initial feature values. This data-driven technique can be used to generate cascading failure data set for any real-world power grids and hence, power-grid engineers can use this approach for cascade data generation and hence predicting vulnerabilities and enhancing robustness of the grid.

6 June 2022 in IEEE Systems Journal
Verified
Journal Article
Closed access
PDPankaz Das
Pankaz Das
RSRezoan A. Shuvro
Rezoan A. Shuvro
KPKassie Povinelli
Kassie Povinelli
FSFrancesco Sorrentino
Francesco Sorrentino
MHMajeed M. Hayat
Majeed M. Hayat
Despite the reliability of modern power systems, large blackouts due to cascading failures (CFs) do occur in power grids with enormous economic and societal costs. In this article, CFs in power grids are theoretically modeled proposing a Markov decision process (MDP) framework with the aim of developing optimal load-shedding (LS) policies to mitigate CFs. The embedded Markov chain of the MDP, established earlier to capture the dynamics of CFs, features a reduced state-space and state-dependent transition probabilities. We introduce appropriate actions affecting the dynamics of CFs and associated costs. Optimal LS policies are computed that minimize the expected cumulative cost associated with CFs. Numerical simulations on the IEEE 118 and IEEE 300 bus systems show that the actions derived by the MDP result in minimum total cost of CFs, compared to fixed and random policies. Moreover, the optimality of derived policies is validated by a CF simulation based on dc power flow for the IEEE 118 bus system. Therefore, such actions developed by the proposed theoretical MDP framework can serve as a baseline for devising optimal LS strategies to mitigate CFs in power grids.

5 April 2022 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
RSRezoan Ahmed Shuvro
Rezoan Ahmed Shuvro
PDPankaz Das
Pankaz Das
JJJamir Shariar Jyoti
Jamir Shariar Jyoti
JAJoana M. Abreu
Joana M. Abreu
MHMajeed M. Hayat
Majeed M. Hayat
The reliable operation of power grids during cascading failures is heavily dependent on the interdependencies between the power grid components and the supporting communications and control networks. Moreover, the system operators’ expertise in dealing with cascading failures can play a pivotal role during contingencies. In this paper, a dynamical probabilistic model is developed based on Markov-chains, which captures the dynamics of cascading failures in the power grid. Specifically, a previously developed Markov-chain based model is extended to capture the trade-off between the benefits of having a robust communication infrastructure and its vulnerability from data integrity (e.g., cyber-attacks). State-space reduction of the complex interactions between power grids, communication networks and system operators is achieved by judiciously specifying the state variables of the Markov chain. The impact of system operators’ probability of error during a cascade-mitigation action is incorporated into the model as a function of the state variables of the Markov chain. A point of diminishing returns is observed beyond which the effect of information infidelity outweighs the benefits of having more information. For a given level of cyber threat, an optimal size of a communication network is observed that minimizes the expected number of transmission-line failures before the cascade stops.

1 October 2006 in Applied Optics
Verified
Journal Article
Open access
PDF file
Unal SakogluUnal Sakoglu
Unal Sakoglu
MHMajeed M. Hayat
Majeed M. Hayat
JTJ. Scott Tyo
J. Scott Tyo
PDPhilip Dowd
Philip Dowd
SASenthil Annamalai
Senthil Annamalai
SKSanjay Krishna
Sanjay Krishna
It has recently been reported that by using a spectral-tuning algorithm, the photocurrents of multiple detectors with spectrally overlapping responsivities can be optimally combined to synthesize, within certain limits, the response of a detector with an arbitrary responsivity. However, it is known that the presence of noise in the photocurrent can degrade the performance of this algorithm significantly, depending on the choice of the responsivity spectrum to be synthesized. We generalize this algorithm to accommodate noise. The results are applied to quantum-dot mid-infrared detectors with bias-dependent spectral responses. Simulation and experiment are used to show the ability of the algorithm to reduce the adverse effect of noise on its spectral-tuning capability.

19 July 2021 in IEEE Transactions on Network Science and Engineering
Verified
Journal Article
Closed access
KBKshitij Bhatta
Kshitij Bhatta
MHMajeed M. Hayat
Majeed M. Hayat
FSFrancesco Sorrentino
Francesco Sorrentino
Symmetries are widespread in physical, technological, biological, and social systems and networks, including power grids. The swing equation is a classic model for the dynamics of powergrid networks. The main goal of this paper is to explain how network symmetries affect the swing equation transient and steady state dynamics. We introduce a modal decomposition that allows us to study transient effects, such as the presence of overshoots in the system response. This modal decomposition provides insight into the peak flows within the network lines and allows a rigorous characterization of the effects of symmetries in the network topology on the dynamics. Our work applies to both cases of homogeneous and heterogeneous parameters. Further, the model is used to show how small perturbations propagate in networks with symmetries. Finally, we present an application of our approach to a large power grid network that displays symmetries.