17 August 2022 in International Journal of Control, Automation, and Systems
23 May 2024 in Virtual Reality
Robotic surgery is preferred over open or laparoscopic surgeries due to its intuitiveness and convenience. However, prolonged use of surgical robots can cause neck pain and joint fatigue in wrist and fingers. Also, input systems are bulky and difficult to maintain. To resolve these issues, we propose a novel input module based on real-time 3D hand tracking driven by RGB images and MediaPipe framework to control surgical robots such as patient side manipulator (PSM) and endoscopic camera manipulator (ECM) of da Vinci research kit. In this paper, we explore the mathematical basis of the proposed 3D hand tracking module and provide a proof-of-concept through user experience (UX) studies conducted in a virtual environment. End-to-end latencies for controlling PSM and ECM were 170 ± 10 ms and 270 ± 10 ms, respectively. Of fifteen novice participants recruited for the UX study, thirteen managed to reach a qualifiable level of proficiency after 50 min of practice and fatigue of hand and wrist were imperceivable. Therefore, we concluded that we have successfully developed a robust 3D hand tracking module for surgical robot control and in the future, it would hopefully reduce hardware cost and volume as well as resolve ergonomic problems. Furthermore, RGB image driven 3D hand tracking module developed in our study can be widely applicable to diverse fields such as extended reality (XR) development and remote robot control. In addition, we provide a new standard for evaluating novel input modalities of XR environments from a UX perspective.
12 October 2024 in Biomedical Engineering Letters
With the advent of robot-assisted surgery, user-friendly technologies have been applied to the da Vinci surgical system (dVSS), and their efficacy has been validated in worldwide surgical fields. However, further improvements are required to the traditional manipulation methods, which cannot control an endoscope and surgical instruments simultaneously. This study proposes a speech recognition control interface (SRCI) for controlling the endoscope via speech commands while manipulating surgical instruments to replace the traditional method. The usability-focused comparisons of the newly proposed SRCI-based and the traditional manipulation method were conducted based on ISO 9241-11. 20 surgeons and 18 novices evaluated both manipulation methods through the line tracking task (LTT) and sea spike pod task (SSPT). After the tasks, they responded to the globally reliable questionnaires: after-scenario questionnaire (ASQ), system usability scale (SUS), and NASA task load index (TLX). The completion times in the LTT and SSPT using the proposed method were 44.72% and 26.59% respectively less than the traditional method, which shows statistically significant differences (p < 0.001). The overall results of ASQ, SUS, and NASA TLX were positive for the proposed method, especially substantial reductions in the workloads such as physical demands and efforts (p < 0.05). The proposed speech-mediated method can be a candidate suitable for the simultaneous manipulation of an endoscope and surgical instruments in dVSS-used robotic surgery. Therefore, it can replace the traditional method when controlling the endoscope while manipulating the surgical instruments, which contributes to enabling the continuous surgical flow in operations consequentially.
29 August 2026 in Journal of Computational Design and Engineering
The COVID-19 pandemic overwhelmed hospital capacities, prompting the use of patient isolation units (PIUs) to flexibly expand containment in emergency rooms (ERs). However, existing studies primarily rely on static analyses and rarely quantify the direct infection risk to healthcare workers (HCWs). To address these, we propose an integrated framework to simultaneously minimize the aerosol dispersion index (ADI) and infection risk index (IRI) under dynamic conditions. A multistage methodology integrating computational fluid dynamics, surrogate modeling, and the non-dominated sorting genetic algorithm II was developed to analyze 120 dynamic scenarios. Optimal solutions were derived to quantify the improvements in ADI and IRI relative to general operation. Furthermore, the technique for order preference by similarity to ideal solution algorithm was employed to determine the optimal distributions of the PIU operational parameters and HCW behavioral factors based on weighted priorities. The optimized strategy demonstrated enhanced improvements in both ADI and IRI compared to the general operation. Optimal control minimized instances where IRI exceeded levels observed without a PIU, while simultaneously enhancing ADI. Variable analysis revealed that the optimal fan filter unit operation depends heavily on the specific dynamic conditions. Furthermore, maintaining physical distance emerged as a consistently dominant factor in reducing IRI, whereas respiratory avoidance efficacy was largely negated by turbulence. This study highlights the necessity and effectiveness of adaptive optimization in PIUs. Implementing intelligent strategies and adaptive control algorithms that respond to real-world environmental changes is essential for comprehensive infection control in high-risk environments.