Viktoriya V. Kirsanova

Viktoriya V. Kirsanova

Auto-generated profile, based on publicly available information

Viktoriya V. Kirsanova

Professor V.F. Voino-Yasenetsky Krasnoyarsk State Medical University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2023 in Clinical Dentistry (Russia)
Verified
Journal Article
Open access
PDF file
ВКВ.в. Кирсанова
В.в. Кирсанова
TFTaras Vladimirovich Furtsev
Taras Vladimirovich Furtsev
РЛР.с. Лукин
Р.с. Лукин
Важная клиническая роль в убыли костной ткани отводится микрозазору между установленным имплантатом и абатментом. В зависимости от размера микрозазора, его локализации и стабильности при жевательной нагрузке можно судить о прогнозе выживаемости имплантата в условиях постоянной микробной контаминации. Однако на сегодняшний день, помимо оригинальной, на стоматологическом рынке представлена и неоригинальная супраструктура с соответствующими сертификатами качества. Перспектива ее использования требует углубленного изучения. Цель — сравнить величины микрозазора в коническом соединении имплантатов различных систем с оригинальным и неоригинальным абатментом под действием жевательной нагрузки. Для исследования были выбраны имплантаты и стандартные абатменты трех имплантационных систем: Straumann BL (Швейцария), BioHorizons Tapered Internal (США), Nobel Biocare CC (Швейцария), а также неоригинальные абатменты системы ADM Dental (Россия). В ходе эксперимента с помощью метода конечных элементов моделировалась жевательная нагрузка силой 150, 300 и 450 Н, измерялась величина микрозазора и горизонтального отклонения абатмента от исходной оси. Для анализа степени различий показателей оригинальных и неоригинальных абатментов использовался пакет DTW (Dynamic Time Warping) языка программирования Python. Наибольшие значения горизонтального отклонения абатмента наблюдаются у образцов системы Nobel; абатменты BioHorizons имеют наименьшее среднее отклонение при нагрузке в 150 Н; супраструктура Straumann показала наименьшее отклонение при нагрузках в 300 и 450 Н. Наибольшие значения остаточного отклонения абатмента наблюдаются у образцов системы Nobel, наименьшие — у BioHorizons. Наибольшие значения микрозазора при латеральной нагрузке выявлены в системе BioHorizons, наименьшие — в Straumann. Максимальный остаточный микрозазор после разгрузки наблюдается в системе Nobel, нулевые значения остаточных микрозазоров показала система Straumann. Только у Straumann в 100% случаев соединение имплантата с оригинальным абатментом демонстрирует меньшие значения микрозазора и горизонтального отклонения по сравнению с неоригинальным абатментом. В остальных случаях наблюдается тенденция меньших значений при использовании неоригинальной супраструктуры. Применение оригинальной или неоригинальной супраструктуры коррелирует с величиной микрозазора в коническом соединении, а полученные данные говорят о возможности применения неоригинальных абатментов в клинической практике. При этом большее влияние на полученные величины оказывает не выбор в пользу оригинального или неоригинального абатмента, а особенности самой нагружаемой имплантационной системы. Micro-gap between the placed implant and the abutment plays an important clinical part in the bone loss. Depending on the micro-gap width, its localization and stability under oblique load, we can predict the prognosis of the implant survival under conditions of constant microbial contamination. However, a non-original abutment with relevant quality certificates is also presented at the dental market in addition to the original one. The prospect of its using requires in-depth study. The aim of this study is to compare the micro-gap values at the conical connection of implants from different systems with the original and non-original abutment under oblique load. . Implants and standard abutments of three implant systems were selected for the study: Straumann BL (Switzerland), BioHorizons Tapered Internal (USA), Nobel Biocare CC (Switzerland), as well as non-original abutments of the ADM Dental system (Russia). During the experiment, an oblique loading of 150, 300 and 450 N was applied by the finite element method, and the micro-gap width and the horizontal abutment deflection from the initial axis were measured. The DTW (Dynamic Time Warping) package of the Python programming language was used to analyze the...

15 October 2024 in Russian Journal of Dentistry
Verified
Journal Article
Closed access
PDF file
VKViktoriya V. Kirsanova
Viktoriya V. Kirsanova
TFTaras Vladimirovich Furtsev
Taras Vladimirovich Furtsev
RLRoman S. Lukin
Roman S. Lukin
Background: For implant-supported restorations, clinicians use both original and non-original abutments, which are widely available in today’s dental market. The finite element analysis previously conducted by the authors revealed that the microgap size in a taper connection depends on the selected abutment and affects the state of the marginal bone surrounding the implant. Aim: To determine the distinguishing factor between original and non-original abutments that has the greatest impact on the microgap size in a taper connection during masticatory force modeling. Materials and methods: The study used Straumann Bone Level (BL), BioHorizons Tapered Internal, and NobelParallel Conical Connection (CC) implants and standard abutments, as well as non-original ADM Dental abutments. Before conducting a serial computational experiment, the geometric parameters of the samples were manually measured. In the first stage of the study, four main factors were identified: screw material, abutment material, screw geometry, and abutment geometry. The calculations were based on the authors’ earlier research findings and were performed using finite element modelling with the Mechanical module of the ANSYS Workbench software. The NeoScan N80 microtomography system was used in the second stage of the study. Moreover, the microgap size and length of cone generatrixes between the components were measured to better understand the geometry of the samples. The results were processed using the DataViewer and CTVox (Bruker Micro-CT) software. Results: The abutment geometry had the greatest impact on the microgap size of a taper connection in both the Straumann BL and BioHorizons Tapered Internal systems. In the NobelParallel CC system, the abutment screw geometry had a greater impact on the microgap size. The microtomography findings revealed a difference in the length of implant-abutment cone generatrixes for the Straumann BL (0.1 mm) and BioHorizons Tapered Internal (0.07 mm) systems, with no difference between the original and non-original abutment for NobelParallel CC implants. The cone generatrix of the screw is smaller with the original NobelParallel CC abutment compared to the non-original one. This is the only negative difference value (–0.34 mm), with the modulus significantly exceeding that of the difference between Straumann BL (0.2 mm) and BioHorizons Tapered Internal (0.2 mm). Conclusion: The study revealed that selecting an original versus non-original abutment has a greater impact on the microgap size of a taper connection due to differences in abutment geometry, particularly the geometry of its fixing screw.

29 August 2025 in Russian Journal of Dentistry
Verified
Journal Article
Closed access
PDF file
VKViktoriya V. Kirsanova
Viktoriya V. Kirsanova
TFTaras Vladimirovich Furtsev
Taras Vladimirovich Furtsev
BACKGROUND: Dental implantation is one of the most advanced techniques for restoring masticatory function in modern dentistry. However, the use of non-original abutments manufactured by third-party companies remains controversial, particularly regarding their effect on long-term prosthetic outcomes. This study assesses the influence of abutment type—original vs non-original—on peri-implant bone stability. AIM: This study aimed to evaluate the association between the type of dental prosthetic components—original or non-original—and long-term outcomes of implant-supported prostheses, based on clinical case analysis. METHODS: A retrospective analysis of panoramic radiographs was performed in patients who received Straumann Bone Level (BL) (Straumann, Switzerland), Nobel Biocare Conical Connection (CC) (Nobel Biocare, USA), or BioHorizons Tapered Internal (BioHorizons, USA) dental implants, with a follow-up period of up to 11 years. Radiographic evaluation included assessment of peri-implant bone levels and the incidence of peri-implantitis. RESULTS: The χ2 test revealed no statistically significant differences (p 0.05) between the groups using original and non-original abutments. The analyzed clinical cases confirmed no direct correlation between abutment type and long-term prosthetic success. CONCLUSION: The abutment type does not significantly influence the success of implant-supported prosthetic treatment. However, it may represent one of multiple factors that collectively contribute to long-term outcomes.