17 February 2009 in British Journal of Surgery
MSM. H. F. Schreinemacher
Background: In laparoscopic ventral hernia repair a mesh is placed in direct contact with the viscera, often leading to substantial adhesions. In this experimental study the ability of different coated and uncoated meshes to attenuate adhesion formation was examined. Methods: Six commercially available meshes were placed intraperitoneally against a closed peritoneum in rats: Prolene® (polypropylene), Timesh® and Ultrapro® (polypropylene composites with titanium and polyglecaprone respectively), Proceed® and Parietex Composite® (polypropylene and polyester meshes coated with a layer of cellulose and collagen respectively) and C‐Qur® (polypropylene mesh coated with a layer of omega‐3 fatty acids). Adhesions and incorporation were evaluated macroscopically and microscopically after 7 and 30 days. Results: Parietex Composite® and C‐Qur® significantly reduced adhesion formation at 7 days' follow‐up compared with all other meshes. By 30 days, this effect had diminished as a significant increase in adhesions together with phagocytosis of the coating was seen for all meshes with layered coatings (Proceed®, Parietex Composite® and C‐Qur®). Incorporation was insufficient for all meshes. Conclusion: The absorbable layers of Parietex Composite® and C‐Qur® reduce adhesion formation to intraperitoneal mesh in the short term, but the effect diminishes and phagocytosis of absorbable coatings may contribute to adhesion formation. Copyright © 2009 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
30 December 2016 in Surgical Endoscopy
Background Single-incision laparoscopic cholecystectomy (SILC) might maximize the advantages of laparoscopic cholecystectomy (LC) by reducing postoperative pain and improving cosmesis. However, the safety and feasibility of SILC has not yet been established. This study assesses safety, patient reported outcome measures and feasibility of SILC versus conventional LC. Methods Literature search for RCT’s comparing SILC with conventional LC in gallstone-related disease was performed in PubMed and Embase. The conventional LC was defined as two 10-mm and two 5-mm ports. Study selection was done according to predefined criteria. Two reviewers assessed the risk of bias. Pooled outcomes were calculated for adverse events, pain, cosmesis, quality of life and feasibility using fixed-effect and random-effects models. Results Nine RCT’s were included with total of 860 patients. No mortality was observed. More mild adverse events (RR 1.55; 95% CI 0.99–2.42) and significantly more serious adverse events (RR 3.00; 95% CI 1.05–8.58) occurred in the SILC group. Postoperative pain (MD -0.46; 95% CI -0.74 to -0.18) and cosmesis (SMD 2.38; 95% CI 1.50–3.26) showed significantly better results for the SILC group, but no differences were observed in quality of life. Operating time (MD 23.12; 95% CI 11.59–34.65) and the need for additional ports (RR 11.43; 95% CI 3.48–37.50) were significantly higher in the SILC group. No difference was observed in conversion to open cholecystectomy or hospital stay longer than 24 h. Conclusions SILC does not provide any clear advantages over conventional LC except for less postoperative pain and improved cosmesis. It is questionable whether these advantages outweigh the higher occurrence of adverse events and shortcomings in feasibility. Considering considerable heterogeneity and low methodological quality of the studies it is advisable to perform well-designed RCT’s in the future to address the safety and clinical benefits of SILC.
2 December 2020 in Surgical Endoscopy
Background: Infection with SARS-CoV-2 causes corona virus disease (COVID-19). The most standard diagnostic method is reverse transcription-polymerase chain reaction (RT-PCR) on a nasopharyngeal and/or an oropharyngeal swab. The high occurrence of false-negative results due to the non-presence of SARS-CoV-2 in the oropharyngeal environment renders this sampling method not ideal. Therefore, a new sampling device is desirable. This proof-of-principle study investigated the possibility to train machine-learning classifiers with an electronic nose (Aeonose) to differentiate between COVID-19-positive and negative persons based on volatile organic compounds (VOCs) analysis. Methods: Between April and June 2020, participants were invited for breath analysis when a swab for RT-PCR was collected. If the RT-PCR resulted negative, the presence of SARS-CoV-2-specific antibodies was checked to confirm the negative result. All participants breathed through the Aeonose for five minutes. This device contains metal-oxide sensors that change in conductivity upon reaction with VOCs in exhaled breath. These conductivity changes are input data for machine learning and used for pattern recognition. The result is a value between − 1 and + 1, indicating the infection probability. Results: 219 participants were included, 57 of which COVID-19 positive. A sensitivity of 0.86 and a negative predictive value (NPV) of 0.92 were found. Adding clinical variables to machine-learning classifier via multivariate logistic regression analysis, the NPV improved to 0.96. Conclusions: The Aeonose can distinguish COVID-19 positive from negative participants based on VOC patterns in exhaled breath with a high NPV. The Aeonose might be a promising, non-invasive, and low-cost triage tool for excluding SARS-CoV-2 infection in patients elected for surgery.
21 December 2015 in BMC Gastroenterology
Anastomotic leakage (AL) remains the most dreaded complication after colorectal surgery and causes high morbidity and mortality. The pathophysiology of AL remains unclear, despite numerous studies that have been conducted on animals and humans, probably due to the undetermined healing process of colorectal anastomoses. Increasing basic knowledge on this healing process may shed more light on causal factors of AL, and additionally reduce the quantity and accelerate the quality of experimental studies. In this debate article, our aim was to provide different perspectives on what is known about the colorectal healing process in relation to wound healing and AL. Since knowledge on anastomotic healing is lacking, it remains difficult to conclude which factors are essential in preventing AL. This is essential information in the framework of humane animal research, where the focus should lie on Replacement, Reduction and Refinement (3Rs). While many researchers compare anastomotic healing with wound healing in the skin, there are substantial recognized differences, e.g. other collagen subtypes and different components involved. Based on our findings in literature as well as discussions with experts, we advocate stop considering anastomotic healing in the gastrointestinal tract and cutaneous healing as a similar process. Furthermore, intervention studies should at least address the anastomotic healing process in terms of histology and certain surrogate markers. Finally, the anastomotic healing process ought to be further elucidated – with modern techniques to achieve 3Rs in animal research - to provide starting points for potential interventions that can prevent AL.
3 September 2010 in World Journal of Surgery
MSMarc H. F. Schreinemacher
Marc H. F. Schreinemacher
Background: Postoperative adhesions are the most frequent complication of abdominal surgery, leading to high morbidity, mortality, and costs. However, the problem seems to be neglected by surgeons for largely unknown reasons.Methods: A survey assessing knowledge and personal opinion about the extent and impact of adhesions was sent to all Dutch surgeons and surgical trainees. The informed‐consent process and application of antiadhesive agents were questioned in addition.Results: The response rate was 34.4%. Two thirds of all respondents (67.7%) agreed that adhesions exert a clinically relevant, negative effect. A negative perception of adhesions correlated with a positive attitude regarding adhesion prevention (ρ = 0.182, p < 0.001). However, underestimation of the extent and impact of adhesions resulted in low knowledge scores (mean test score 37.6%). Lower scores correlated with more uncertainty about indications for antiadhesive agents which, in turn, correlated with never having used any of these agents (ρ = 0.140, p = 0.002; ρ = 0.095, p = 0.035; respectively). Four in 10 respondents (40.9%) indicated that they never inform patients on adhesions and only 9.8% informed patients routinely. A majority of surgeons (55.9%) used antiadhesive agents in the past, but only a minority (13.4%) did in the previous year. Of trainees, 82.1% foresaw an increase in the use of antiadhesive agents compared to 64.5% of surgeons (p < 0.001).Conclusions: The magnitude of the problem of postoperative adhesions is underestimated and informed consent is provided inadequately by Dutch surgeons. Exerting adhesion prevention is related to the perception of and knowledge about adhesions.
8 June 2013 in Surgical Endoscopy