1 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
4 September 2025 in Proceedings of the National Academy of Sciences
Self-assembled thin films respond to external loads via surface instabilities that are critical to their functionality in both biology and technology. Lipid monolayers at the air–liquid interface are one such system. Tunability between out-of-plane buckling (e.g., folding) and in-plane relaxation (e.g., reorganization of lipid domains) in highly compressed lipid monolayers suggests underlying mechanistic generality. Yet, how in-plane relaxation occurs and how it is distinguished from folding remains elusive. Here, we use continuum mechanics, finite element (FE) simulations, and Langmuir trough fluorescence microscopy (FM) data to elucidate the underlying mechanisms of these elastic instability modes. Uniaxial loading of the Langmuir trough is evaluated in FE simulations, where the lipid monolayer is modeled as a thin sheet with a hyperelastic energy function developed to exhibit a relaxation mechanism. Results show that this material relaxation mechanism triggers tunable in-plane shear localization (shear banding). Furthermore, the simulation results of a heterogeneous model, built from fluorescence micrographs of lipid domains distributed in a continuous matrix, are rigorously compared with experimental data by domain organizational analyses. These analyses suggest shear bands are sufficient in inducing domain symmetry breaking that is characteristic of in-plane relaxation and, without such shear bands, domain organization remains in powder structure, characteristic of folding lipid monolayers. Our findings develop a hyperelastic model validated against experimental FM images that can connect the observed lipid monolayer instabilities of folding and in-plane relaxation, establishing a generalized framework with the potential to unify all other monolayer instability modes and characterize other thin film systems.
1 February 2020 in Biophysical Journal
24 October 2026 in medRxiv
Vascular pathology often manifests in complex shape evolution visualized by longitudinal computed tomography (CT) imaging. Growth and remodeling (G&R) frameworks have been integrated into finite element (FE) modeling to probe the mechanics underlying this progression, extending into patient-specific approaches. Their scalability and translatability, however, are limited by the computational burden associated with heterogeneous, anisotropic growth fields and through-thickness meshing. While existing shell growth formulations can mitigate this burden, they require nontrivial FE implementation especially in commercial softwares (e.g., Abaqus) and their efficacy in patient-specific geometries under complex loading is unclear. In this work, we present a general computational framework to implement shell morphoelastic growth computed directly from registered patient-specific CT images. This shell implementation is validated against solid 3D formulations, allows thickness tunability, and increases compatibility with CT surfaces. We demonstrate the robustness of this formulation through modeling post-operative growth in a patient-specific aortic dissection under stent-based loading. Results first show that complex stent-based loading can deform the shell dissection flap to reproduce post-operative geometry. The outer aortic wall is then given a growth field calculated from registration of 1-month and 5-year post-operative CT images, which is implemented along with stent-based loading and pressurization. Results from this model capture the trends in total and lumen morphological evolution observed at intermediate timepoints. These findings establish a general framework, validated with a patient-specific case study of aortic dissection, with the potential to expand to other complex systems, scale to larger patient populations, and apply G&R to clinical translation.
1 February 2019 in Biophysical Journal