Haohua Zhang

Haohua Zhang

Auto-generated profile, based on publicly available information

Haohua Zhang

Guangxi Key Laboratory of Information Materials, Guilin University of Electronic Technology, Guilin 541004, PR China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2024 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
JWJiaao Wu
Jiaao Wu
ZLZhihao Liu
Zhihao Liu
HZHaohua Zhang
Haohua Zhang
YZYongjin Zou
Yongjin Zou
BLBin Li
Bin Li
TYTing Yu
Ting Yu

6 August 2023 in Orthopaedic Surgery
Verified
Journal Article
Open access
HZHaohua Zhang
Haohua Zhang
YSYang Song
Yang Song
CLCheng Li
Cheng Li
YDYong Dou
Yong Dou
DWDacheng Wang
Dacheng Wang
DLDi Liu
Di Liu
Objective: Remote assessment and diagnosis of functional impairment caused by osteoarthritis (OA) of the knee can achieve early intervention of patients’ functional impairment, prevent the deterioration of OA of the knee, and provide functional remote screening for patients with knee OA. This study introduced an inertial measurement unit (IMU) sensor‐based system to assess lower extremity function and perform gait analysis. Then, we compared its accuracy to gold‐standard motion capture and gait measurement systems.Methods: Nine adults were selected to participate in a comparative study of gait assessment outcomes using an IMU sensor‐based wearable system, a gold‐standard motion capture system, and a pressure‐based gait analysis system. The subject walked on a path that incorporated all three systems. Data analysis was performed on spatiotemporal gait parameters, including velocity, cycle time, cadence, and stride length. This was followed by gait phases, including stance, swing, double stance, and single limb support phases. Data were processed using the data processing software of each system. An independent sample t‐test was conducted for inter‐group comparison to analyze the data.Results: The spatiotemporal gait parameters of the systems demonstrated excellent consistency, and the gait phases showed high consistency. Compared to the gold‐standard pressure‐based gait analysis system (the GATERite system), the mean gait cycle time results were 1.124 s vs. 1.127 s (p = 0.404); cadence was 93.333 steps/min vs. 94.189 steps/min (p = 0.482); stance phase was 60.89% vs. 63.26% (p < 0.001); swing phase was 39.11% vs. 36.74% (p < 0.001); stride length was 1.404 m vs. 1.420 m (p = 0.743); speed was 1.093 m/s vs. 1.110 m/s (p = 0.725). Compared to the gold‐standard video‐based motion capture system, the root mean square error was 2.7° for the hip angle and 2.6° for the knee angle.Conclusions: This IMU‐based wearable system delivered precise measuring results to evaluate patients with knee OA. This technology can also be used to guide rehabilitation exercises for patients with knee OA.