Edward R. Damiano

Edward R. Damiano

Auto-generated profile, based on publicly available information

Edward R. Damiano

Department of Biomedical Engineering, Boston University, Boston, Massachusetts

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2014 in New England Journal of Medicine
Verified
Journal Article
Open access
PDF file
SRSteven J. Russell
Steven J. Russell
FEFiras H. El-Khatib
Firas H. El-Khatib
MSManasi Sinha
Manasi Sinha
KMKendra L. Magyar
Kendra L. Magyar
KMKatherine McKeon
Katherine McKeon
EDEdward R. Damiano
Edward R. Damiano
The safety and effectiveness of automated glycemic management have not been tested in multiday studies under unrestricted outpatient conditions. In two random-order, crossover studies with similar but distinct designs, we compared glycemic control with a wearable, bihormonal, automated, “bionic” pancreas (bionic-pancreas period) with glycemic control with an insulin pump (control period) for 5 days in 20 adults and 32 adolescents with type 1 diabetes mellitus. The automatically adaptive algorithm of the bionic pancreas received data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon. Among the adults, the mean plasma glucose level over the 5-day bionic-pancreas period was 138 mg per deciliter (7.7 mmol per liter), and the mean percentage of time with a low glucose level (<70 mg per deciliter [3.9 mmol per liter]) was 4.8%. After 1 day of automatic adaptation by the bionic pancreas, the mean (±SD) glucose level on continuous monitoring was lower than the mean level during the control period (133±13 vs. 159±30 mg per deciliter [7.4±0.7 vs. 8.8±1.7 mmol per liter], P<0.001) and the percentage of time with a low glucose reading was lower (4.1% vs. 7.3%, P=0.01). Among the adolescents, the mean plasma glucose level was also lower during the bionic-pancreas period than during the control period (138±18 vs. 157±27 mg per deciliter [7.7±1.0 vs. 8.7±1.5 mmol per liter], P=0.004), but the percentage of time with a low plasma glucose reading was similar during the two periods (6.1% and 7.6%, respectively; P=0.23). The mean frequency of interventions for hypoglycemia among the adolescents was lower during the bionic-pancreas period than during the control period (one per 1.6 days vs. one per 0.8 days, P<0.001). As compared with an insulin pump, a wearable, automated, bihormonal, bionic pancreas improved mean glycemic levels, with less frequent hypoglycemic episodes, among both adults and adolescents with type 1 diabetes mellitus. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov numbers, NCT01762059 and NCT01833988.)

5 June 2009 in Circulation Research
Verified
Journal Article
Closed access
PDF file
DPDaniel R. Potter
Daniel R. Potter
JJJohn Jiang
John Jiang
EDEdward R. Damiano
Edward R. Damiano
Compelling evidence continues to emerge suggesting that the glycocalyx surface layer on vascular endothelial cells plays a determining role in numerous physiological processes including inflammation, microvascular permeability, and endothelial mechanotransduction. Previous research has shown that enzymes degrade the glycocalyx, whereas inflammation causes shedding of the layer. To track the endogenous recovery of the glycocalyx in vivo, we used fluorescent microparticle image velocimetry (μ-PIV) in mouse cremaster muscle venules to estimate the hydrodynamically relevant glycocalyx thickness 1, 3, 5, and 7 days after enzymatic or cytokine-mediated degradation of the layer. Results indicate that after acute degradation of the glycocalyx, 5 to 7 days are required for the layer to endogenously restore itself to its native hydrodynamically relevant thickness in vivo. In light of these findings, and because demonstrable evidence has emerged that standard cell culture conditions are not conducive to providing the environment and/or cellular conditions necessary to produce and maintain a physiologically relevant cell surface glycocalyx in vitro, we sought to determine whether merely the passage of time would be sufficient to promote the production of a hydrodynamically relevant glycocalyx on a confluent monolayer of human umbilical vein endothelial cells (HUVECs). Using μ-PIV, we found that the hydrodynamically relevant glycocalyx was substantially absent 7 days postconfluence on HUVEC-lined cylindrical collagen microchannels maintained under standard culture conditions. Thus, it remains to be determined how a hydrodynamically relevant glycocalyx surface layer can be synthesized and maintained in culture before the endothelial cell culture model can be used to elucidate glycocalyx-mediated mechanisms of endothelial cell function.

1 March 2016 in The Lancet Diabetes & Endocrinology
Verified
Journal Article
Closed access
SRSteven J Russell
Steven J Russell
MHMallory A Hillard
Mallory A Hillard
CBCourtney Balliro
Courtney Balliro
KMKendra L Magyar
Kendra L Magyar
RSRajendranath Selagamsetty
Rajendranath Selagamsetty
FEFiras H El-Khatib
Firas H El-Khatib

13 October 2012 in Diabetes Care
Verified
Journal Article
Open access
PDF file
SRSteven J. Russell
Steven J. Russell
FEFiras H. El-Khatib
Firas H. El-Khatib
DNDavid M. Nathan
David M. Nathan
KMKendra L. Magyar
Kendra L. Magyar
JJJohn Jiang
John Jiang
EDEdward R. Damiano
Edward R. Damiano
OBJECTIVE To test whether safe and effective glycemic control could be achieved in type 1 diabetes using a bihormonal bionic endocrine pancreas driven by a continuous glucose monitor in experiments lasting more than two days and including six high-carbohydrate meals and exercise as challenges to glycemic control. RESEARCH DESIGN AND METHODS Six subjects with type 1 diabetes and no endogenous insulin secretion participated in two 51-h experiments. Blood glucose was managed with a bionic endocrine pancreas controlling subcutaneous delivery of insulin and glucagon with insulin pumps. A partial meal-priming bolus of insulin (0.035 units/kg/meal, then 0.05 units/kg/meal in repeat experiments) was administered at the beginning of each meal (on average 78 ± 12 g of carbohydrates per meal were consumed). Plasma glucose (PG) control was evaluated with a reference quality measurement on venous blood every 15 min. RESULTS The overall mean PG was 158 mg/dL, with 68% of PG values in the range of 70–180 mg/dL. There were no significant differences in mean PG between larger and smaller meal-priming bolus experiments. Hypoglycemia (PG <70 mg/dL) was rare, with eight incidents during 576 h of closed-loop control (0.7% of total time). During 192 h of nighttime control, mean PG was 123 mg/dL, with 93% of PG values in the range of 70–180 mg/dL and only one episode of mild hypoglycemia (minimum PG 62 mg/dL). CONCLUSIONS A bihormonal bionic endocrine pancreas achieved excellent glycemic control with minimal hypoglycemia over the course of two days of continuous use despite high-carbohydrate meals and exercise. A trial testing a wearable version of the system under free-living conditions is justified.

1 March 2007 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
PDF file
FEFiras H. El-Khatib
Firas H. El-Khatib
JJJohn Jiang
John Jiang
EDEdward R. Damiano
Edward R. Damiano
In order to stave off deleterious complications of the disease, the ultimate task for people with diabetes is to maintain their blood glucose in euglycemic range. Despite technological advancements, conventional open-loop therapy often results in prolonged hyperglycemia and episodic hypoglycemia, in addition to necessitating carbohydrate counting, frequent glucose monitoring, and drug administration. The logical conclusion in the evolution of exogenous insulin therapy is to develop an automated closed-loop control system. Eleven closed-loop control experiments were conducted in four anesthetized diabetic pigs, with carbohydrate loads simulated by intravenous glucose administration through ear-vein catheters. Type 1 diabetes-like pathology was induced using intravenous administration of cytotoxin streptozotocin. The augmented model-predictive control algorithm accounts for the accumulation of subcutaneous insulin, which is critical in avoiding excessive insulin dosing. Control results consistently showed successful blood-glucose regulation to euglycemic range within 80–120 minutes after intravenous glucose loads, with no incidence of hypoglycemia. This is consistent with a negative oral glucose tolerance test for diabetes and is the optimal postprandial regulation that can be achieved with subcutaneous insulin administration. Results also demonstrated the potency of subcutaneous glucagon in staving off episodic hypoglycemia and revealed efficacy of the control algorithm in coping with a twofold variation in subject weights, while simultaneously overlooking erratic blood-glucose fluctuations. Using an automated adaptive glucose-control system, we show successful blood-glucose regulation in vivo and establish, definitively, the plausibility and practicality of closed-loop blood-glucose control using subcutaneous insulin and glucagon infusion in type 1 diabetes. The control system strikes an intricate balance between tight blood-glucose control and optimal drug consumption, while simultaneously maintaining emphasis on simplicity and reliability.

9 November 2020 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
RJRabab Jafri
Rabab Jafri
CBCourtney Balliro
Courtney Balliro
FEFiras El-Khatib
Firas El-Khatib
MSMichele Sullivan
Michele Sullivan
MHMallory Hillard
Mallory Hillard
SRSteven J Russell
Steven J Russell
Background: There is a dearth of comparative accuracy studies of continuous glucose monitoring (CGM) devices in the home-use setting, and none with the Eversense implantable CGM. Methods: We evaluated the accuracy of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense during a 6-week free-living home-use bionic pancreas study involving 23 subjects with type 1 diabetes who wore all three devices concurrently. The primary outcome was the mean absolute relative difference (MARD) between CGM readings and point-of-care (POC) plasma-glucose (PG) values obtained approximately twice daily by the subjects. We compared PG values with CGM readings when available from all three CGMs in the 5 min preceding the PG values ( n = 829 sets). Since the Libre Pro records readings every 15 min, we also did a two-way comparison between the G5 and the Eversense with a higher number of comparisons ( n = 2277 sets). Results: All three CGM systems produced higher average MARDs than during in-clinic studies. However, since all three CGM systems were worn by the same individuals and used the same meter for comparator PG measurements, we could directly compare their performances. In the three-way comparison, Eversense achieved the lowest nominal MARD (14.8%) followed by Dexcom G5 (16.3%) and Libre Pro (18.0%) (Eversense vs. Libre Pro P = 0.004, other comparisons P = NS). There was a statistically significant difference ( P = 0.008) in the two-way comparison of the MARDs for Eversense (15.1%) and G5 (16.9%). Conclusions: The point accuracy of the Eversense was better than two other CGMs when compared with POC PG values.