Diana Cardenas del Monaco

Diana Cardenas del Monaco

Auto-generated profile, based on publicly available information

Diana Cardenas del Monaco

Texas Neurosciences Institute, San Antonio, TX

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in International Journal of Spine Surgery
Verified
Journal Article
Closed access
WNWarren F. Neely
Warren F. Neely
FFFrank Fichtel
Frank Fichtel
DMDiana Cardenas del Monaco
Diana Cardenas del Monaco
Jon E BlockJon E Block
Jon E Block
Many first generation stand-alone fusion cages required endplate decortication and surgical impaction during the procedure resulting in segmental subsidence, implant migration and loss of lordosis postoperatively. The primary objective of this study was to evaluate radiographically, in a large series of patients, whether engineering and design modifications incorporated in a specific stand-alone, expandable interbody fusion device (VariLift(®)-L) adequately addressed previously recognized deficiencies of stand-alone interbody cages. In this retrospective chart review of 470 patients (642 treated levels), we evaluated radiographic evidence of fusion, subsidence and migration following a one- or two-level PLIF procedure utilizing this stand-alone expandable interbody fusion device. A secondary objective was to corroborate the low morbidity and symptomatic improvements achieved with previous interbody cage devices used to treat symptomatic disc degeneration. The average postoperative followup was 3.9 ± 1.8 years and a solid fusion rate of 94% was achieved among patients with ≥ 9 months of radiographic followup. Subsidence > 3 mm was noted at 10 levels with no cases of device migration. Composite back pain severity scores improved from 8.5 ± 1.5 preoperatively to 0.8 ± 1.5 at final followup (p<0.001) and 94% of patients met or exceeded the minimal clinical important difference of 3.8 points. Eighteen patients required reoperation following the index procedure; 16 of these patients were treated for adjacent segment disease. The VariLift-L device has excellent clinical and technical performance characteristics, providing adequate stabilization of the anterior column without the need for supplemental posterior instrumentation. Level of Evidence IV. IRB Approval: Expedited Federal Register Categories 5& 7: Methodist IRB 3/30/2011; Informed Consent statement: retrospective data collection, patients signed consent forms allowing for data to be used for research. This stand-alone expandable fusion device produced high fusion rates, a low incidence of reoperation and effective symptom relief in a "real world" setting among a large group of patients with refractory symptomatic disc degeneration.

1 May 2015 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
LFLouis C Fielding
Louis C Fielding
EEErik Emstad
Erik Emstad
DMDiana Cardenas del Monaco
Diana Cardenas del Monaco
JBJon Block
Jon Block
Intervertebral fusion cages have been in clinical use since the 1990s. Cages offer the benefits of bone graft containment, restored intervertebral and foraminal height, and a more repeatable, stable procedure compared to interbody fusion with graft material alone. Due to concerns regarding postoperative stability, loss of lordosis, and subsidence or migration of the implant, interbody cages are commonly used with supplemental fixation such as pedicle screw systems or anterior plates. While providing additional stability, supplemental fixation techniques increase operative time, exposure, cost, and morbidity. The VariLift® Interbody Fusion System (VariLift® system) has been developed as a standalone solution to provide the benefits of intervertebral fusion cages without the requirement of supplemental fixation. The VariLift® system, FDA-cleared for standalone use in both the cervical and lumbar spine, is implanted in a minimal profile and then expanded in situ to provide segmental stability, restored lordosis, and a large graft chamber. Preclinical testing and analyses have found that the VariLift® System is durable, and reduces stresses that may contribute to subsidence and migration of other standalone interbody cages. Fifteen years of clinical development with the VariLift® system have demonstrated positive clinical outcomes, continued patient maintenance of segmental stability and lordosis, and no evidence of implant migration. The purpose of this report is to describe the VariLift® system, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The VariLift® System represents an improved surgical option for a stable interbody fusion without requiring supplemental fixation.

1 January 2015 in International Journal of Spine Surgery
Verified
Journal Article
Closed access
RARoberto J. Aranibar
Roberto J. Aranibar
DMDiana Cardenas del Monaco
Diana Cardenas del Monaco
PGPhoebe Gonzales
Phoebe Gonzales
Osteomyelitis of the spine is a fairly uncommon event following an orthopedic surgical procedure. However, a solitary osteomyelitic abscess of the upper cervical spine is very rare. Surgical intervention is often the only life-saving treatment method. A 70-year-old female patient with diabetes was received from a rural community with symptoms of progressive quadraparesis and progressive respiratory failure. A CT scan of the cervical spine showed a destruction of the C1 and C2 complex, as well as the left occipital condyle, and clear evidence of craniocervical instability. She underwent surgical debridement of the abscess via an anterior microscopic transtubular approach, followed by a posterior occipital-cervical fusion. While a transoral approach is a well-established procedure for the anterior clivus/C1-2 area, it is fraught with a high degree of morbidity and mortality. The use of the transtubular anterior cervical approach in this case allowed us to access the C1-2 area with ease and minimal effort. From a technical standpoint, this type of approach for treatment of this condition has not been previously documented in the literature.