Divya Pai

Divya Pai

Auto-generated profile, based on publicly available information

Divya Pai

Department of Orthodontics & Dentofacial Orthopaedics Manipal Karnataka 576104 Manipal College of Dental Sciences

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in IEEE Access
Verified
Journal Article
Open access
DRDivya Rao
Divya Rao
RSRohit Singh
Rohit Singh
SKSudiksha Kottachery Kamath
Sudiksha Kottachery Kamath
SPSanjeev Kushal Pendekanti
Sanjeev Kushal Pendekanti
DPDivya Pai
Divya Pai
SPSameena Begum Pathan
Sameena Begum Pathan
Otoscopy is a diagnostic procedure to visualize the external ear canal and eardrum, facilitating the detection of various ear pathologies and conditions. Timely otoscopy image classification offers significant advantages, including early detection, reduced patient anxiety, and personalized treatment plans. This paper introduces a novel OTONet framework specifically tailored for otoscopy image classification. It leverages octave 3D convolution and a combination of feature and region-focus modules to create an accurate and robust classification system capable of distinguishing between various otoscopic conditions. This architecture is designed to efficiently capture and process the spatial and feature information present in otoscopy images. Using a public otoscopy dataset, OTONet has reached a classification accuracy of 99.3% and an F1 score of 99.4% across 11 classes of ear conditions. A comparative analysis demonstrates that OTONet surpasses other established machine learning models, including ResNet50, ResNet50v2, VGG16, Dense-Net169, and ConvNeXtTiny, across various evaluation metrics. The research’s contribution to improved diagnostic accuracy reduced human error, expedited diagnostics, and its potential for telemedicine applications.

11 April 2023 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
DPDivya Pai
Divya Pai
AUArun S. Urala
Arun S. Urala
KGKishore Ginjupalli
Kishore Ginjupalli
KPKalyana Chakravarthy Pentapati
Kalyana Chakravarthy Pentapati
GAGaurav Agrawal
Gaurav Agrawal
Introduction. Clinicians should be aware of any effect the oral environment may have on archwires. Laboratory models fail to closely imitate intraoral conditions. The aim was to evaluate the change in mechanical properties of preformed stainless steel archwires after 15 weeks of exposure to the oral environment. Methods. Three commercially manufactured 0.0190.025 stainless steel archwires were evaluated. Youngs modulus, yield strength, spring factor, and hardness were studied. The unexposed distal end cuts (control samples) and archwires were tested after 15weeks of intraoral exposure (test samples). Tension tests, Vickers microhardness tests, and nanoindentation tests were carried out. Results. Normality was tested using the ShapiroWilk test. Statistical analyses included the paired t-test for intragroup comparisons and KruskalWallis ANOVA with the post hoc Dunn test for comparison of mean percentage reduction in values. At T15, Youngs modulus showed a statistically significant decrease. Changes in yield strength and spring factor were not significant for groups other than American Orthodontics wires. The reduction in hardness was significant in 3M Unitek. Vickers, tension, and nanoindentation tests demonstrated an expansive range between hardness and Youngs modulus so determined. Conclusion. 3M Unitek archwires showed the highest difference in Youngs modulus. Yield strength values increased in Ortho Organizers archwires. Spring factor decreased only in 3M Unitek archwires. Hardness values obtained from various tests did not produce identical results.

1 January 2026 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
DSDivya Siddalingappa
Divya Siddalingappa
DPDivya Pai
Divya Pai
CCChetan Kumar Chiniwalar
Chetan Kumar Chiniwalar
KPKalyana Chakravarthy Pentapati
Kalyana Chakravarthy Pentapati
AUArun S Urala
Arun S Urala
Purpose: To compare the effect of maxillary splint high pull head gear (MSHPH) on dentoskeletal structures in growing Class II division 1 patients with a matched control group. Methods: The treatment group (MSHPH) comprised 20 patients who were evaluated at two stages: pretreatment (T1) and post orthopaedic (T2). The control group consisted of 20 untreated class II patients under observation. Intra-group comparisons were done with paired t test and the inter-group comparisons were analyzed with “Mann–Whitney U-test”. Results: Intra-group comparisons in the treated group showed significant decrease in the mean SNA, ANB, N perpendicular to Point A, Point A vertical, PNS vertical, U1 – NA (angular), U1 – SN, U1 – NA (linear), U1 – NF, PtV – U6, overjet and overbite at T2 when compared to T1. However, there was a significant increase in the mean SNB, N-Pog, EMnL, LAFH, at T2. The control group showed significant increase in the mean SNA, ANB, N perpendicular to Pogonion, Effective MxL, Effective MnL, LAFH, Point A vertical, ANS vertical, PNS vertical, U1 – NA (angular), U1 – SN, U1 – NA (linear), U1 – NF, PtV – U6, and overjet at T2 when compared to T1. Inter-group comparisons (T2-T1) showed significantly higher mean in treated group for SNA, SNB, ANB, N perpendicular to Point A, N perpendicular to Pogonion, Effective MnL, U1 – NA (angular), U1 – SN, U1 – NA (linear), U1 – NF, PtV – U6, overjet, overbite, S line Upper Lip and S line to Lower Lil. However, significantly lower values were seen in treated group for Effective MxL, LAFH, Point A vertical, ANS vertical, and PNS vertical. Conclusion: MSHPH held the maxilla without changes in the palatal plane. Thus, normal skeletal relationships resulted from inhibiting maxillary growth and preserving natural mandibular development in the treatment group.

25 September 2026 in F1000Research
Verified
Journal Article
Open access
PDF file
ASAdithya Narayan S
Adithya Narayan S
RSRitesh Singla
Ritesh Singla
RMRajat Mitra
Rajat Mitra
DPDivya Pai
Divya Pai
RNRashmi Nayak
Rashmi Nayak
SBSimarpreet Bhamra
Simarpreet Bhamra
Background Conventional enamel conditioning with 37% phosphoric acid is commonly used for orthodontic bracket bonding but causes enamel demineralization. Erbium, chromium-doped yttrium scandium gallium garnet laser conditioning has been proposed as an alternative. This study compared the shear bond strength and adhesive remnant patterns of orthodontic brackets following three enamel-conditioning protocols. Methods Fifty-one extracted human premolars were randomly allocated to three groups (n = 17 per group). Enamel was conditioned with 37% phosphoric acid for 15 seconds in Group I, an erbium, chromium-doped yttrium scandium gallium garnet laser (2780 nm, 2 W, 25 Hz) for 10 seconds in Group II, or acid etching followed by laser irradiation in Group III. Stainless steel orthodontic brackets were bonded, and shear bond strength was measured using a universal testing machine. Adhesive remnants were assessed using the Adhesive Remnant Index and digital image analysis. Statistical significance was set at p < 0.05. Results Median shear bond strength was 13.70 MPa in the acid group, 11.55 MPa in the laser group, and 16.24 MPa in the combined group. No statistically significant difference was found among the groups (χ 2 [2] = 4.17, p = 0.229). Adhesive Remnant Index distributions differed significantly among the groups (χ 2 [6] = 18.17, p = 0.0008). Score 3, indicating that all adhesive remained on the enamel, was most frequent in the acid group. Score 0, indicating that no adhesive remained, was most frequent in the combined group. Conclusions All three conditioning protocols produced clinically acceptable shear bond strength. Combined acid and laser conditioning produced the highest median bond strength and less residual adhesive after debonding, although the difference in bond strength was not statistically significant.