Folic acid (FA) plays an indispensable role in human body and sometimes needs to be taken as a drug supplement, especially for pregnant women. Herein, an electrochemical FA sensor was constructed by electrodepositing Cu and ferrocene carboxylic acid (Fc(COOH)) on a glassy carbon electrode (GCE), indicating low cost, simple preparation and short time consumption. Furthermore, the field emission scanning electron microscopy illustrates that Fc(COOH) completely covering Cu nanoparticles (CuNPs) grew to be tufts of loose and porous nanoflowers in situ, which produces a large active surface area to adsorb FA. Results verify that two conjected materials exhibited a good synergistic amplification effect on FA signal. Ultimately, a great linear relationship of FA was established between 100.0 ∼ 1000.0 μ M under optimized conditions by differential pulse voltammetry (DPV). The limit of detection was 33.3 μ M, and the sensitivity was 0.10149 μ A· μ M −1 ·cm −2 . The sensor Fc(COOH)/CuNPs/GCE showed satisfactory selectivity and stability and could be used for FA detection in FA tablets samples with an average recovery of 91.43 ∼ 100.68%, and a relative standard deviation less than 3.17%. The consistency and validity were affirmed by comparisons with an ultra-visible spectrophotometer.
28 October 2025 in IEEE Sensors Journal
The enzyme-free electrochemical detection of glucose requires an alkaline environment. Digital microfluidic (DMF) chips can change the pH value of droplets by droplet fusion operation, but the traditional manufacturing process is complex. In this article, we designed an easy-tofabricate PCB-based DMF chip and developed a multistep driving method to drive the droplets. The test droplet containing glucose (only 50 μL) can be mixed with the NaOH droplet in a 1:1 volume ratio under the control of the DMF chip, resulting in an alkaline environment. A three-electrode system consisting of a gold (Au) working electrode, a gold (Au) reference electrode, and a gold (Au) counter-electrode was designed. Unmodified disk electrodes were used, and a two-step method was developed to activate the electrodes. A three-step method, including electrochemical cleaning-electrolyzed water (optimizing the microenvironment of the working electrode)–amperometric i–t curve test, was designed to test the mixed droplets. The experimental results show that the multistep droplet driving method can drive droplets more stably than the traditional method. Within 0–1 mM, the relationship between the concentration (C) of glucose aqueous solution and the current (I) is as follows: I = 0.0182C (μM) + 8.6402 (R2 = 0.9981), and the limit of detection (LOD) is 73.09 μM. Within 1–20 mM, I = 39.611lnC (mM) + 18.826 (R2 = 0.9834, LOD = 1.03 mM). We also investigated the influence of environmental factors on the reaction and verified the feasibility of using this test method to test sweat glucose and blood glucose using PBS solutions with pH 5 and 7.4, respectively.
1 October 2025 in Journal of the Electrochemical Society
Trans-resveratrol (TRA) has garnered significant attention due to its multiple pharmacological activities. This study fabricated a Zn-MOF/MWNTs-OH/GCE electrochemical detection platform for TRA detection by modifying a glassy carbon electrode (GCE) with a composite of hydroxyl-functionalized multi-walled carbon nanotubes (MWNTs-OH) and zinc-based metal-organic framework (Zn-MOF). The structure and composition of the materials were characterized using scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and X-ray diffraction. The results indicate that the Zn-MOF/MWNTs-OH/GCE has an excellent electrochemical response to TRA, featuring a linear detection range of 1.00–600.00 μM and a detection limit of 0.32 μM. Additionally, the detection platform exhibits good reproducibility, stability, and selectivity. In the grape skin sample detection, the recovery rate ranges from 98.48% to 105.19%, the RSD is less than 4.62%, and the accuracy of the results is verified by fluorometry.