Yuntao Zou

Yuntao Zou

Auto-generated profile, based on publicly available information

Yuntao Zou

School of Electrical, Computer, and Energy Engineering, Arizona State University, Tempe, AZ, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HZHaitao Zhang
Haitao Zhang
MMMahmoud Mehrabankhomartash
Mahmoud Mehrabankhomartash
MSMaryam Saeedifard
Maryam Saeedifard
YZYuntao Zou
Yuntao Zou
YMYongqing Meng
Yongqing Meng
XWXiuli Wang
Xiuli Wang
Stability analysis of the point-to-point high-voltage dc (HVdc) transmission systems is crucial for planning and operational purposes. However, due to the protection of trade secret and user privacy, it is difficult to have access to detailed information of the converters of an HVdc system. To avoid detailed information of the converters during system stability assessment, this article adopts a hybrid ac-dc impedance model along with a new network partitioning method to assess stability of the point-to-point HVdc system. The proposed method has the following advantages. First, in contrast to the conventional stability analysis methods, the number of right half-plane poles of the system minor-loop gain is not required. Second, different from the conventional impedance models, the hybrid ac-dc impedance excludes the impacts of the impedances of the ac grid and dc networks, to which the converter is connected. Accordingly, the hybrid ac-dc impedance model solely depends on the converter itself. In addition to the proposed method, this article demonstrates that the power flow direction of a point-to-point HVdc system has no impact on selection of different system minor-loop gains. Accuracy and effectiveness of the proposed method are evaluated and validated by time-domain and frequency-domain simulations in the MATLAB/Simulink environment.

8 June 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLei Zhang
Lei Zhang
JQJiangchao Qin
Jiangchao Qin
YZYuntao Zou
Yuntao Zou
QDQing Duan
Qing Duan
WSWanxing Sheng
Wanxing Sheng
This paper investigates and compares various modulation methods and capacitor voltage-balancing algorithms of modular multilevel converter (MMC) for solid-state transformer (SST) applications. Characteristics of capacitor charging and discharging are analyzed for the existing single-step alternating voltage-balancing and the conventional sorting algorithms with phase-shift (PS) modulation and nearest-level control (NLC) methods. Based on the analysis, the single-step alternating algorithm leads to a low-frequency voltage ripple while the conventional sorting algorithm introduces additional switching actions. To address these issues, two new voltage-balancing algorithms are proposed, i.e., a multi-step alternating voltage-balancing algorithm and a current-less sorting algorithm. The performance of the proposed algorithms with the PS and NLC modulation methods are comprehensively investigated and compared based on theoretically analysis and experimental results. The study results demonstrate the capability of the proposed methods to balance capacitor voltages while reducing the low-frequency voltage ripple and avoiding additional switching actions.

14 October 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYuntao Zou
Yuntao Zou
LZLei Zhang
Lei Zhang
JQJiangchao Qin
Jiangchao Qin
WSWanxing Sheng
Wanxing Sheng
QDQing Duan
Qing Duan
The traditional power decoupling control of modular multilevel converter (MMC) is based on the phase synchronization achieved by the phase-locked loop (PLL), and MMC intricate inner dynamics are ignored, which jeopardizes the system stability and power decoupling. To improve the performance, a nonlinear phase-unsynchronized power decoupling control for MMC is proposed without PLL. At first, the MMC model as a nonlinear multi-input multi-output system is developed. The developed model illustrates that the MMC power coupling is caused by the ac current as well as the MMC capacitor voltages. Then, through the input–output linearization method, the proposed method decouples the MMC output powers without the phase synchronization. Involving integral control, the dynamics of MMC output powers are designed as second-order systems so that the control parameters can be easily determined based on the required transient performance. To verify the accuracy and correctness of the developed model, a comparison of MMC dynamics with the proposed control is conducted between the numerical solution in MATLAB and the EMT simulation in PSCAD/EMTDC. Moreover, seven cases in the EMT simulations and four cases in the experimental results demonstrate the desired phase asynchronization and power decoupling performance of the proposed method compared with the conventional $dq$ control. At last, the system zero dynamic stability is investigated and the influences of MMC control parameters, ac-side voltage, dc-side voltage and equilibrium points are analyzed to evaluate the stability performance of the proposed method.

31 December 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YZYuntao Zou
Yuntao Zou
JQJiangchao Qin
Jiangchao Qin
LZLei Zhang
Lei Zhang
JYJicheng Yu
Jicheng Yu
This paper proposes an inequality constraints based method to efficiently and quickly estimate stability regions of droop control slopes for modular multilevel converter (MMC)-based multi-terminal dc (MTDC) systems. At first, a general small-signal model of the MMC-MTDC system is developed, which consists of the dc network and the MMCs with $dq$ controllers and multiple droop controllers. When deriving corresponding nonlinear state-space models, the edge-node matrix is introduced for the dc network modeling with arbitrary grid topology and transmission line model. Then, based on the eigenvalues sensitivity and the Taylor Series of eigenvalues, a set of inequality constraints are proposed to expeditiously estimate the suprema of the droop slopes and identify the droop slope stability regions for the MMC-MTDC system. To verify the state-space model, a comparison of dynamic responses between the math model calculation in MATLAB and the EMT simulation in PSCAD/EMTDC is conducted, which demonstrates the accuracy and the correctness of the developed small-signal model. The effectiveness of the proposed parameter stability region estimation method is demonstrated by several examinations including the supremum tests of droop slopes, the stability region sketches on accuracy, and the predicted unstable operations in PSCAD/EMTDC.

24 February 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HPHamed Pourgharibshahi
Hamed Pourgharibshahi
YZYuntao Zou
Yuntao Zou
RGRobson Bauwelz Gonzatti
Robson Bauwelz Gonzatti
FPFang Zheng Peng
Fang Zheng Peng
YLYuan Li
Yuan Li
HLHui Li
Hui Li
This paper illustrates the practical implementation of Y-Matrix Modulation for a medium voltage grid-tie Switched-Capacitor Modular Multilevel Converter (SC-MMC) with a middle submodule. SC-MMC only contains switches and capacitors, and there is no physical arm inductor. Through Y-Matrix Modulation, SC-MMC has the capability of self-voltages balancing. Y-Matrix Modulation also eliminates the need for voltage sensors and complicated feedback controls. Moreover, Y-Matrix Modulation can be used for both half-bridge and full-bridge structures for any N-level MMC. Therefore, this modulation is very effective owing to its simplicity, modularity, and sensorless features. Additionally, SC-MMC with a middle submodule can generate the same voltage level with fewer cells. A modified Y-Matrix Modulation is needed with the minimum number of sensors. This paper provides experimental implementation of this modulation for a medium voltage grid-tie converter. Y-Matrix generation is simplified using a less computationally demanding method. Y-Matrix Modulation for 4-submodule SC-MMC with a middle submodule is demonstrated in this paper and compared with conventional modulations. A real-time computer hardware in the loop setup and small-scale experimental setup is used to verify the operation of the controller under steady-state and transient conditions.

1 April 2026
Verified
Book Chapter
Closed access
YBYongjian Bi
Yongjian Bi
XTXisheng Tang
Xisheng Tang
GLGuanjie Liu
Guanjie Liu
TWTaian Wang
Taian Wang
YZYuntao Zou
Yuntao Zou