1 April 2017 in Journal of Performance of Constructed Facilities
This study focuses in the impact of vehicle speed, vehicle type, and transverse rumble strip (TRS) design on the sound pressure level perceived by drivers when they traverse a TRS. TRSs are commonly installed on approaches to toll plazas and at intersections, etc. The ability of a TRS to capture a driver’s attention is directly related to the magnitude of the sound and vibration. However, the traffic noise generated by TRS creates a problem for adjacent residences and businesses near the roadway. Thus, the aim of this study is to quantify the level of traffic noise and verify the effects of TRS shapes. The research team measured the exterior noise, inner noise, and vibration generated by three types of vehicles (sedan, minivan, and truck) traveling over four types of transverse rumble strip applications (Types A, B, C, and D) with speed range between 40 and 100 km/h. In general, the increase in the exterior noise generated was greater at 100 km/h than at 40 km/h and lower for a sedan than for a...
1 November 2014 in KSCE Journal of Civil Engineering
As part of the research to evaluate the Warm-Mix Asphalt (WMA) performance for use in Korea, an extensive testing program has been conducted on the warm-mix asphalt technology that is newly developed in Korea, along with Hot Mix Asphalt (HMA). This research program consists of Accelerated Pavement Test (APT) and laboratory test. This paper presents the rutting and fatigue performance test results of both WMA and HMA. The rut development due to trafficking loading was evaluated using APT with 8.2 ton loading at 40°C temperature. The transverse profile was measured periodically at each point per test section as a function of mixture types. In order to investigate the fatigue performance, APT applied trafficking loading under wet and dry condition. The very stiff base is likely to complicate the planned fatigue cracking test, in that a huge number of APT repetitions will be generally required before any distress occurs. In this study, therefore, the fatigue test was conducted at 20°C with adding water into the aggregate base layer to accelerate the distress after the given trafficking loading. Cores were taken to be tested in the laboratory after construction of the test track as well as after completion of APT testing on and off the wheel path. The air voids were measured for all cores and dynamic modulus test and fatigue test in indirect testing mode were conducted. Based on the limited data obtained from this study, it is concluded that WMA mixture performs comparable to HMA mixture in terms of rutting and fatigue resistance.